• Title/Summary/Keyword: Light Floor

Search Result 279, Processing Time 0.026 seconds

The Slit Beam Laser Calibration Method Based On Triangulation (삼각법을 이용한 슬릿 빔 레이저 캘리브레이션)

  • 주기세
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.168-173
    • /
    • 1999
  • Many sensors such as a laser, CCD camera to obtain 3D information have been used, but most of calibration algorithms are inefficient since a huge memory and an experiment data for laser calibration are required. In this paper, the calibration algorithm of a slit beam laser based on triangulation method is introduced to calculate 3D information in the real world. The laser beam orthogonally mounted on the XY table is projected on the floor. A Cm camera observes the intersection plane of a light and an object plane. The 3D information is calculated using observed and calibration data. This method saves a memory and an experimental data since the 3D information are obtained simply triangulation method.

  • PDF

Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy (태양열 온수 및 난방 일체형 복합시스템의 성능예측)

  • Han, Yuri;Park, Youn Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

APPLICATION OF UNCERTAINTY ANALYSIS TO MAAP4 ANALYSES FOR LEVEL 2 PRA PARAMETER IMPORTANCE DETERMINATION

  • Roberts, Kevin;Sanders, Robert
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.767-790
    • /
    • 2013
  • MAAP4 is a computer code that can simulate the response of a light water reactor power plant during severe accident sequences, including actions taken as part of accident management. The code quantitatively predicts the evolution of a severe accident starting from full power conditions given a set of system faults and initiating events through events such as core melt, reactor vessel failure, and containment failure. Furthermore, models are included in the code to represent the actions that could mitigate the accident by in-vessel cooling, external cooling of the reactor pressure vessel, or cooling the debris in containment. A key element tied to using a code like MAAP4 is an uncertainty analysis. The purpose of this paper is to present a MAAP4 based analysis to examine the sensitivity of a key parameter, in this case hydrogen production, to a set of model parameters that are related to a Level 2 PRA analysis. The Level 2 analysis examines those sequences that result in core melting and subsequent reactor pressure vessel failure and its impact on the containment. This paper identifies individual contributors and MAAP4 model parameters that statistically influence hydrogen production. Hydrogen generation was chosen because of its direct relationship to oxidation. With greater oxidation, more heat is added to the core region and relocation (core slump) should occur faster. This, in theory, would lead to shorter failure times and subsequent "hotter" debris pool on the containment floor.

Analysis of Meridians Potential as Ground Condition for Objectification of Acupuncture Effect (침술 효과의 객관화를 위한 접지조건에 따른 경락전위분석)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.436-441
    • /
    • 2007
  • Background: As patients are positioned at insulated bed and practitioner are positioned at insulated floor or shoes, it could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. Method: We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground, respectively. Result: All ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. practitioner ground only showed negative mean potential $-51.5{\pm}9.3{\mu}V\;and\;367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential as $2.9{\pm}1.3{\mu}V,\;16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential as $1.6{\pm}0.7{\mu}V,\;3.3{\pm}1.9{\mu}V$ of peak to peak potential. respectively.

Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses (공동주택의 배치유형에 따른 창호 시스템의 채광특성)

  • Kim, Gon;Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

The Characteristics of Frank Lloyd Wright's Furniture Design focused on Organic Integration (유기적 통합의 개념으로 본 프랭크 로이드 라이트의 가구디자인 특성)

  • Moon Eun-Mi
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.115-122
    • /
    • 2006
  • The purpose of this study is to investigate the design principles of organic integration on furniture design by Frank Lloyd Wright. He consistently pursued organic principles in interior design, furniture and equipments. He insisted that every elements of a building can be integrated into architecture as if architecture can be a part of the nature. The study surveyed and analyzed the examples of furniture design in Wright houses from the viewpoints of spacial and formal integration as well as organic evolution. The study finds the characteristics of organic integration on furniture design as follows. He designed built-in furniture as an important part of the house, which seemed to grow up from the architecture design and a part of a building. He also designed and arranged free-standing furniture as spacial device in open floor plan. Moreover, furniture design repeated same geometry, modules, and proportion system of house design in order to integrate Into the building. In addition, material and color of furniture follow those of architecture. Wright's furniture design had changed from heavy forms in his early prairie houses to light and practical shapes in his Usonian period.

Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses (국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

A Study on the Adaptable Long Life Multi-dwelling Housing Design in Korea (융통성을 고려한 장수명 공동주택 디자인에 관한 연구)

  • Kim, Jin-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.6 s.59
    • /
    • pp.172-177
    • /
    • 2006
  • Most of the Korean multi-dwelling houses have less than 20 years of lifespan. Because the environmental issues such as energy consumption, limited resources, and demolition waste problems became been more and more critical, we now need to focus on long lasting and adaptable buildings. Korean wall bearing apartment buildings are constructed with site cast concrete for core, exterior, and interior together with pipes varied, so when the buildings are old and life style of the users changes, it is difficult to maintain and renovate these buildings. In this study, to resolve the problems described above, two types of Korean long life multi-dwelling housing models which represent improved durability and adaptability responding user's needs and life style changes were proposed with various methods as follows: Either column and beam structure or flat slab structure was used to utilize space better. To make maintenance easier and renovation economical for both public space and each unit, plumbing pipes, ducts, and conduits were clustered at the cores and public corridors with access doors and light weight partitions with steel studs and raised floors or above-ceiling spaces were used in lieu of site cast concrete walls and floor slabs with varied pipes.

Analysis on Results evaluated by "Housing Performance Grading System" in Korea (주택성능등급 인정 사례의 부문별 평가 결과 분석)

  • Lee, Sung Ok
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.55-66
    • /
    • 2010
  • The government is enacted "Housing Performance Grading Indication System" from qualitative housing supply policy and performance of housing under the background of looking for new plan to secure good housing stock and housing performance. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are sound insulation related grading(Light-weight impact sound insulation, heavy-weight floor impact sound insulation, noise emission in bathroom, airborne sound insulation for wall between units), Long-life housing related grading(flexibility, remodeling & maintenance, durability), environment related grading(landscape, indoor air quality and ventilation, energy performance), Living environment related grading(common resident facilities such as playground and consideration for the socially underprivileged such as the aged), Fire fire prevention grading(fire fire prevention). The purpose of this research is to analyze characteristics and assessment results of 20 detailed performance items on "Housing Performance Grading Indication System" which was enforced 240 cases from Jan 9th, 2006 to Sep 30th, 2010. The analysis of approval condition of detailed performance items will be important comments for understanding the current domestic level and development of technology.

Space study on Lighting Performance For Residential Buildings By using Simulation Analysis (시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구)

  • Lim, Tae Sub;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.