• Title/Summary/Keyword: Light Distribution

Search Result 1,826, Processing Time 0.034 seconds

Development of Optical System for 50W LED Security Lamp (50W급 LED 보안등용 조명광학계 개발)

  • Jung, Byoung-Jo;Jang, Sung-Whan;Roh, Yong-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.296-305
    • /
    • 2012
  • In this paper, we develop about glare phenomenon at security light caused by light source's straight characteristic, maintaining uniformity ratio of illuminance as high, have long light distribution not by symmetry of rotation but a single axis. we develop second lens for security light that lack of light distribution phenomenon at each of security light can be solved. Our developed light system design satisfies lighting standard of security light's and shape of lens is single lens. so our lens optimizes designing or analysis by using lighting design and interpretation program. Making a Mock-up to do real measure, we have intensity of illumination and maintaining uniformity ratio of illuminance measurement data.

Enhancement of Optical Performance by Light Diffusion Films

  • Seo, M.S.;Yoon, J.S.;Heo, J.U.;Kim, S.S.;Moon, C.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1262-1265
    • /
    • 2004
  • To increase the performance of the light diffusion films, we controlled the three dimensional microstructure of the organic fillers(beads). The refractive index, the size distribution and the three dimensional distribution of beads play an important role to determine the performance of light diffusion films for the backlight unit of TFT-LCD.

  • PDF

Two Layer DOI Detector Design for PET using Multiple Light Guides for Designing Light Distribution (다수의 광가이드를 통한 빛 분포 설계로 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.703-708
    • /
    • 2022
  • A detector module measuring the depth of interaction(DOI) was designed to improve the spatial resolution of positron emission tomography(PET). The scintillation pixel array consists of two layers, and a light guide is inserted between the layers to make the light generated through the gamma-ray event different for each layer. There are four light guides, and one light guide is designed to be coupled to a 2 × 2 array of scintillation pixels. The light generated from the top layer is moved to the photosensor with a wider distribution through the light guide, and the light generated from the bottom layer is incident on the photosensor with a narrower distribution than the top layer. When a flood image is reconstructed based on the signals obtained from the photosensor by different distributions, scintillation pixels are imaged at different positions for each layer. To verify this, a DETECT2000 simulation tool that simulates the behavior of light in a scintillator was used. By designing a scintillation pixel array, a detector consisting of a light guide and a photosensor, a gamma ray event was generated in all scintillation pixels to obtain a flood imgae. As a result, it was confirmed that the top and bottom layers were imaged at different positions and completely separated. When this detector is applied to PET, it is considered that image quality can be improved through imporved spatial resolution.

Research on the Influence of Inter-turn Short Circuit Fault on the Temperature Field of Permanent Magnet Synchronous Motor

  • Qiu, Hongbo;Yu, Wenfei;Tang, Bingxia;Yang, Cunxiang;Zhao, Haiyang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1566-1574
    • /
    • 2017
  • When the inter-turn short circuit (ITSC) fault occurs, the distortion of the magnetic field is serious. The motor loss variations of each part are obvious, and the motor temperature field is also affected. In order to obtain the influence of the ITSC fault on the motor temperature distribution, firstly, the normal and the fault finite element models of the permanent magnet synchronous motor (PMSM) were established. The magnetic density distribution and the eddy current density distribution were analyzed, and the mechanism of loss change was revealed. The effects of different forms and degrees of the fault on the loss were obtained. Based on the loss analysis, the motor temperature field calculation model was established, and the motor temperature change considering the loop current was analyzed. The influence of the fault on the motor temperature distribution was revealed. The sensitivity factors that limit the motor continuous operation were obtained. Finally, the correctness of the simulation was verified by experiments. The conclusions obtained are of great significance for the fault and high temperature demagnetization of the permanent magnet analysis.

Measurement of Depth Dose Distribution Using Plastic Scintillator

  • Hashimoto, Masatoshi;Kodama, Kiyoyuki;Hanada, Takashi;Ide, Tatsuya;Tsukahara, Tomoko;Maruyama, Koichi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.244-247
    • /
    • 2002
  • We examined a possibility to use inorganic plastic scintillator, which has the effective atomic number close to that of human soft tissue, for the measurement of dose distributions in a shorter time period. The method was to irradiate a block of plastic scintillator as a phantom, and to measure the distribution of the scintillation light by a wave length analyzer through a thread of plastic optical fiber. By irradiating the diagnostic x-ray, we observed the emission spectrum of the scintillation light from the scintillator. It showed a peak at around 420nm with a full width of 140 nm. The emission spectrum was integrated to determine the total number of photons. The dependences of the amount of photons on the irradiated dose were measured. The results of the experiment show that the amount of emission light is in proportional to the irradiated dose. From this fact, we conclude that the present method can be used for the measurement of the depth dose distribution of the diagnostic x-rays.

  • PDF

Autostereoscopic Display Simulator for Providing an Optimal Viewing Zone (무안경방식 디스플레이에서 최적 입체시를 제공하기 위한 시뮬레이터 구현)

  • Lee, Ho-Dong;Park, Min-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8A
    • /
    • pp.698-705
    • /
    • 2012
  • In this paper, we proposed an autostereoscopic display simulator that calculates an extended intensity distribution of light emitted from respective light sources and reaching respective views in an observing area to an observing plane. It simulates intensity distribution in horizontal and vertical observing ranges from the predetermined observing plane and obtains an optimal viewing area image having quantities of light according to respective views based on the intensity distribution data. As a result of the simulation the proposed system enables guiding viewing comfort zone interactively.

The evaluation of diesel emission reduction characteristics by DOC in light-duty vehicle (소형디젤산화촉매의 배출가스 성능평가)

  • 엄명도;류정호;임철수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.34-42
    • /
    • 1999
  • In late 1997, the portion of registered light-duty diesel vehicle was 25.3% and its emission rate was 17.1% in Korea. Especially, diesel particulate matters(DPM) and NOx are hazardous air pollutants to human health and environment in urban area. The reduction technologies of exhaust emissions from diesel engines are improvement of engine combustion, fuel quality and development of diesel exhaust after treatment , In this study , a light-duty diesel oxidation catalyst(DOC) that is one of the diesel exhaust after treatment was made for performance evaluation and the emission characteristics were tested on CVS-75 mode. And the analysis of the particle size distribution with scanning mobility particle 100, 67.6% and 66.7, 10.0% for Pt and Pt-V catalyst .And for Pt catalyst, the PM increased 7.8% because of increasing sulfate but Pt-V catalyst reduced the PM to 23.0% . Test results of particle size distribution showed that peak values of number and mass densities are respectively 100∼200nm their distribution trend independent of vehicle speed.

  • PDF

Feasibility Study of the Light-outcoupling Characteristics of a Diffraction-grating-imprinted Light-guide Plate for an LCD Backlight Unit (LCD 백라이트 유닛의 서브 마이크론 회절 격자 도광판의 광 출사 특성 연구)

  • Choi, Hwan Young
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.4
    • /
    • pp.176-182
    • /
    • 2020
  • The possibility of replacing the condensing-prism film used in conventional backlight units with a light-guide plate engraved with a submicrometer-periodic diffraction grating was investigated. The optimal period for the diffraction grating was determined through simulation and experiment, and the transmission-mode efficiency of the diffraction grating was calculated in terms of the polar angle and azimuthal angle of the incident light. In addition, the effects of the two methods of optimizing the polar angle and the directional angle were compared by simulation, by suggesting the shape and configuration of the light-guide plate, so that more light could be extracted by diffraction. By using a ray-tracing program, the luminance angular distribution of the light-guide plate engraved with the diffraction grating was calculated and compared to the luminance angular distribution for each actual prototype.

A Study for Stray Light Distribution of Mobile Phone Camera Consisting of Two Aspheric Lenses (2매 비구면 렌즈로 구성된 폰 카메라에서 미광 분포에 대한 연구)

  • Park, Kwang-Woo;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.6-15
    • /
    • 2009
  • A mobile phone camera consisting of two aspheric lenses is designed, and stray light distribution on the image plane is analyzed. We assume that most of the incident light is absorbed on the inner surfaces of the lens barrel and spacers, only a small fraction of the light is scattered uniformly. Assuming that 10% of the incident light is scattered on the barrel and spacers, the maximum value of stray light is 7.1% of the ideal image intensity. The result of analysis shows that stray light originated mostly from internal reflection on the ribs. The contributions of scattering by the barrel and spacers are relatively small. To reduce the internal reflection, thin absorbing plates are inserted between lenses, and the shapes of spacers are modified. After the redesigning of the lens barrel, the maximum value of stray light is reduced to 1.1% of the ideal image intensity.

Effects of off-shore plant operating condition on fish distribution (해양플랜트 작업환경이 어류분포에 미치는 영향)

  • YOUN, Sung-Oh;KIM, Hyung-seok;RYU, Kyung-Jin;LEE, Yoo-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.413-422
    • /
    • 2017
  • The objective of this study was to prove possible effects of a habitable place for fish around semi-submersible drilling rig which measured underwater radiated noise, irradiance distribution of rig's light and conducted experimental fishing in Malaysia territory and observed for distribution of fishes around the rig by ROV during drilling operation in the East Sea of Korea. As a result underwater radiated noise was $130dB/{\mu}Pa$ from 156.25 to 187.50 Hz, irradiance distribution of light was between 21.5 and 43.1 lx. Despite this result, underwater radiated noise was not a threat to fish around rig and low irradiance distribution of light also played a role in the luring influence of the fishes at night. Fish showed up in the beginning of drilling operation and at the end of drilling operation. However, there are few fish in the midst of drilling operation. The main reason for this result was the destruction of the habitable place due to blow out mud and broken pieces of ground formation in drilling hole. The results are expected to contribute to reasonable fishery management around rig.