• Title/Summary/Keyword: Light - leakage

Search Result 260, Processing Time 0.026 seconds

Relationship Between Sinapine Leakage Degrees of Radish Seeds and Germination and Morphological Differences of the Seeds and Seedlings (Sinapine 누출정도에 따른 무(Raphanus sativus L.) 종자의 발아율과 종자 및 유묘의 외형적 차이)

  • Min, Tai-Gi;Back, Jun-Ho;Kim, Bok-Jin
    • Applied Biological Chemistry
    • /
    • v.40 no.3
    • /
    • pp.238-242
    • /
    • 1997
  • Seeds of five radish varieties were soaked in water for three hours and cellulose was coated. The seeds were classified as three groups in UV light; non-fluorescent(NF), partly fluorescent(PF), and fully fluorescent(FF) seeds. Germination rate was less in the order of NF>PF>FF seeds. The seed coat structure of NF seeds was dense and showed round shape, while those of PF and FF seeds were wrinkled or ruptured. The cotyledon and hypocotyl of NF seeds were normal, while those of PF and FF seeds were dwarf and showed some scars in the cotyledons.

  • PDF

Micro-CT evaluation of internal adaptation in resin fillings with different dentin adhesives

  • Han, Seung-Hoon;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.24-31
    • /
    • 2014
  • Objectives: The purpose of present study was to evaluate the internal adaptation of composite restorations using different adhesive systems. Materials and Methods: Typical class I cavities were prepared in 32 human third molars. The teeth were divided into the following four groups: 3-step etch-and-rinse, 2-step etch-and-rinse, 2-step self-etch and 1-step self-etch system were used. After the dentin adhesives were applied, composite resins were filled and light-cured in two layers. Then, silver nitrate solution was infiltrated, and all of the samples were scanned by micro-CT before and after thermo-mechanical load cycling. For each image, the length to which silver nitrate infiltrated, as a percentage of the whole pulpal floor length, was calculated (%SP). To evaluate the internal adaptation using conventional method, the samples were cut into 3 pieces by two sectioning at an interval of 1 mm in the middle of the cavity and they were dyed with Rhodamine-B. The cross sections of the specimens were examined by stereomicroscope. The lengths of the parts where actual leakage was shown were measured and calculated as a percentage of real leakage (%RP). The values for %SP and %RP were compared. Results: After thermo-mechanical loading, all specimens showed significantly increased %SP compared to before thermo-mechanical loading and 1-step self-etch system had the highest %SP (p < 0.05). There was a tendency for %SP and %RP to show similar microleakage percentage depending on its sectioning. Conclusions: After thermo-mechanical load cycling, there were differences in internal adaptation among the groups using different adhesive systems.

A Study on the Inverter Type Neon Power Supply Using a Piezoelectric Transformer (압전 변압기를 이용한 인버터식 네온관용 변압기에 관한 연구)

  • 변재영;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.504-511
    • /
    • 2003
  • In this paper, inverter type neon power supply using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed neon power supply is composed of basic circuit and blocks, such as rectifier part, frequency oscillation part and piezoelectric transformer and resonant half bridge inverters. In this paper for complement the low power limitation, piezoelectric transformer at parallel connected driving by inverter is studied for noon tubes system of high power. When piezoelectric transformer is connected with parallel, LC filter connection method with parallel and selection of inductance L and capacitor C of primary side is suggested for reduce unbalanced current at the terminal of each transformer. Piezoelectric transformers use piezoelectric ceramic devices. Thus it is wireless therefore it has high power density, high Isolation level, low loss, more light, and miniaturization. In addition, high voltage transfer ratio is expected because there is no leakage inductance. Also, it has economic merit that the electrical loss Is low because structure is simple, small and tighter weight.

A study on the Risks of Using Filtration Facilities at the Organic Light Emitting Diode(OLED) and Its Preventive Measures (유기발광다이오드(OLED) 소재 제조 현장 여과 설비사용 위험성 및 개선 방안 연구)

  • Jong-Ku Kwak;Chankyu Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.1-11
    • /
    • 2023
  • The size of the OLED material market is expected to grow from $1.1 billion in 2019 to $2.3 billion in 2023, with an average annual sustainable growth of more than 19%. Among the facilities mainly used by OLED material manufacturers, accidents such as fire, explosion, and leakage frequently occur when using filtration equipment, so it is necessary to improve the risk when using filtration equipment. In this study, it was divided into four main processes, namely, assembly and disassembly process, filtration process, wet cake recovery process, and washing process in order to derive the risks associated with the use of filtration equipment. Hazard factors were derived by conducting accident case investigations, preliminary interviews, and surveys. For the analysis of questionnaire results, statistical analysis such as frequency analysis and Pearson chi-square test analysis was performed using SPSS 21, and risk improvement measures were suggested using the analyzed results. It is expected that this study will serve as a basis for dealing with safety and risk factors that may occur as the size of the OLED market expands.

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Growth, Storage and Fresh-cut Characteristics of Onion (Allium cepa L.) in Unstable Environmental Condition and Storage Temperature (양파의 이상 재배조건에서 생육과 저장온도에 따른 저장성 및 포장한 신선편이 특성)

  • Lee, Jung-Soo;Chang, Min-Sun;Park, SuHyoung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.143-154
    • /
    • 2016
  • The purpose of this study was investigated the quality changes before and after harvesting, storage and, processing of onion. Experiments were carried out to compare the effect on the characteristics of the postharvest from preharvest factors using onion. This experiment had identified the characteristics of harvested onions after cultivating with several preharvest factors such as the light and water conditions. These tests were conducted in an onion growth in the field, storage, and processing of fresh-cut during a laboratory periods of 2 years. In first year, onion cultivars ('Kars' and 'Pop') were produced under stable or unstable environment conditions, these onions were stored at low temperature(0?). Measurement was evaluated by the growth amount after harvesting, and the fresh weight loss and respiration rate during storage. According to different culture conditions and storage temperatures, it was investigated the properties of the fresh-cut onion. Growth of onion was varied depending on the cultivars and culture conditions. The amount of growth on 'Kars' and 'Pop' onions were decreased by excessive soil water conditions with shading. These influences were found the morphological differences resulting for the cell tissue of onion being rough and large. Onion cultivated in excessive soil water with shading affected the degree of its respiration rate and fresh weight loss during storage. Ones in excessive soil water with shading were higher than the control in fresh weight loss and respiration rate, respectively. However fresh-cut onion could not investigated to clarify the difference due to effects of cultivation condition and storage temperature on some measure items such as electrolyte leakage and microbial number change. There was a change of only electrolyte leakage depending on the storage temperature, rather than cultivated conditions before harvesting factor. The results showed that the onion grown on in the good environment was represented to a good quality produce even after harvesting.

An Experimental Study on the Myocardial Protection Effects of the Cardioplegic Solution (Cardioplegic Solution의 심근보호 효과에 관한 실험적 연구)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.321-337
    • /
    • 1980
  • The increasing use of cardioplegic solution for the reduction of ischemic tissue injury requires that all cardiplegic solution be carefully assessed for any protective or damaging properties. This study describes functional, enzymatic and structural assessment of the efficiency of three cardioplegic solutions (Young & GIK, Bretschneider, and $K^{+}$ Albumin solution) in a Modified Isolated Rat Heart Model of cardiopulmonary bypass and ischemic arrest. Isolated rat heart were subjected to a 2-minute period of coronary infusion with a cold cardioplegic or a noncardioplegic solution immediately before and also at the midpoint of a 60-minute period of hypothermic ($10{\pm}1$. C) ischemic cardiac arrest. The results of this study were as follow: 1. Spontaneous heart beat after ischemic arrest occured 16 seconds later after Langendorff reperfusion in the Young & GIK group (n=6), and 40 second later in the Bretschneider group (n=6) and 6 minute later in the $K^{+}$ Albumin group (n=6), and 16 minute later in the control group (non-cardioplegia). A good recovery state of spontaneous heart beat was shown in the Young & GIK and Bretschneider groups. 2. The percentage of recorveries of heart function at 30 minute after postischemic working heart perfusion were : heart rate $91.6{\pm}3.1$% (P<0.01)m oeaj airtuc oressyre $83{\pm}3$% (P<0.01), coronary flow $70{\pm}8$% (P<0.05) and aortic flow flow rate $39{\pm}9.3$% (P<0.05) in the Young & GIK group. This percentage of recoveries of the Young & GIK group was significantly greater than the control group. In the Bretschneider group, the percentage of recoveries were : heart rate $87.8{\pm}7.5$%(P<0.05), peak aortic pressure $71{\pm}2.3$% (P<0.05) and aortic flow rate $33.2{\pm}6.6$%(P<0.05). hte percentage of recoveries were significantly greater than in the control group. In the $K^{+}$ Albumin group, recoveries of heart function were poor. 3. Total CPK leakage was $131.2{\pm}12.75$IU/30 min/gm. dry weight in the control group, $50.65{\pm}12.75$IU in the Young & GIK gruop, $69.40{\pm}32.21$Iu in Bretschneider group, and $103.65{\pm}15.47$IU in the $K^{+}$ Albumin group during the 30 minute postischemic Langendorff reperfusion. Total CPK leakage was significantly less (P<0.001) in the Young & GIK group, than in the control group. 4. Direct correlatin between percentage recovery of aortic flow rate and total amount of CPK leakage from Myocardium was noticed.(Correlation Coefficient r = 0.76, P<0.001). 5. Mild perivascular edema was the only finding of light microscopic study of myocardium after 60 minute ischemic arrest with cold cardioplegic solutions and hypothermla.

  • PDF

FEA(Finite Element Analysis) Study for Electronic Hydrogen Regulator of Confidentiality Improvement (전자식 수소레귤레이터 기밀성 향상을 위한 FEA 연구)

  • Son, Won-Sik;Song, Jae-Wook;Jeon, Wan-Jae;Kim, Seung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.175-181
    • /
    • 2019
  • In the case of a conventional single stage decompression regulator used for large depressurization in the hydrogen fuel cell system of a fuel cell electric vehicle (FCEV), problems can arise, such as pulsation, slow response, hydrogen brittleness, leakage, high weight, and high cost due to high decompression. Most of these problems can be overcome easily using two decompression mechanisms (two-stage structures). In addition, a wide outlet-pressure control range can be secured if an electronic solenoid is applied to the second decompression. Accordingly, it is necessary to improve the precision of the outlet pressure of a two-stage pressure-reducing regulator and develop techniques, such as leakage prevention, durability, light weight, and price reduction. Therefore, to improve the outlet pressure accuracy and prevent leakage, the structural part before and after decompression to improve the air tightness were divided and the analysis was carried out assuming that the valve part was closed (open ratio: 0%) after each initial internal pressure application.

Leukocyte Sequestration and Free Radical-Mediated Lung Injury in Ovine Cardiopulmonary bypass Using Membrane Oxygenator (양에서 막형 산화기를 사용하여 심폐바이패스할 경우 백혈구격리 및 자유라디칼로 중재되는 폐손상)

  • 김원곤;신윤철;서정욱
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.978-983
    • /
    • 1999
  • Background: Complement activation with transpulmonary leukocyte sequestration is considered a main mediator leading to ischemia-reperfusion lung(I-R) injury. We studied the role of leukocytes in the formation of I-R injury in ovine cardiopulmonary bypass(CPB) model with a membrane oxygenator. Material and Method: Five sheep were used. CPB circuitry consisted of a roller pump(American Optical Corp., Greenwich, CT, USA) and a membrane oxygenator(UNIVOX-IC, Bentley, Baxter Health Corp, Irvine, CA, USA). The CPB time was fixed at 120 min. Ten minutes after the start of CPB, total CPB was established. Thereafter a total CPB of 100 min was performed, followed by another 10 min of partial CPB. The CPB was discontinued and the animals were fully recovered. For measuring left and right atrial leukocyte counts, blood samples were taken before thoracotomy, 5 min and 109 in after the start of CPB, and 30 min and 120 min after weaning. C3a was measured before thoracotomy, 109 min after the start of CPB, and 30 min and 120 min after weaning. Plasma malondialdehyde(MDA) was checked before thoracotomy, 109 min after the start of CPB, and 30 min after weaning. One to two grams of lung tissue were taken for water content measurement before thoracotomy, 109 min after the start of CPB, and 30 min after weaning. Lung biopsy specimens were examined by light and electron microscopy. Result: Of 5 animals, 4 survived the experimental procedures. Of these, 3 animals survived on a long-term basis. No significant differences in transpulmonary gradients of leukocyte were found and no significant complement activation was expressed by C3a levels. MDA level did not show significant changes related to lung reperfusion despite an increase after the start of CPB. On both light and electron microscopic examinations, mild to moderate acute lung change was observed. Interstitial edema, leakage of erythrocytes into the alveolar space and endothelial cell swelling were the main findings. Water content of the lung showed a slight increase after the start of CPB, but there was no statistical significance. Conclusion: These findings indicate that ischemia-repersusion lung injury may not be from complement activation-leukocyte sequestration but from another source of oxygen free radicals related to CPB.

  • PDF

Effect of the Plasma-assisted Patterning of the Organic Layers on the Performance of Organic Light-emitting Diodes

  • Hong, Yong-Taek;Yang, Ji-Hoon;Kwak, Jeong-Hun;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • v.10 no.3
    • /
    • pp.111-116
    • /
    • 2009
  • In this paper, a plasma-assisted patterning method for the organic layers of organic light-emitting diodes (OLEDs) and its effect on the OLED performances are reported. Oxygen plasma was used to etch the organic layers, using the top electrode consisting of lithium fluoride and aluminum as an etching mask. Although the current flow at low voltages increased for the etched OLEDs, there was no significant degradation of the OLED efficiency and lifetime in comparison with the conventional OLEDs. Therefore, this method can be used to reduce the ohmic voltage drop along the common top electrodes by connecting the top electrode with highly conductive bus lines after the common organic layers on the bus lines are etched by plasma. To further analyze the current increase at low voltages, the plasma patterning effect on the OLED performance was investigated by changing the device sizes, especially in one direction, and by changing the etching depth in the vertical direction of the device. It was found that the current flow increase at low voltages was not proportional to the device sizes, indicating that the current flow increase does not come from the leakage current along the etched sides. In the etching depth experiment, the current flow at low voltages did not increase when the etching process was stopped in the middle of the hole transport layer. This means that the current flow increase at low voltages is closely related to the modification of the hole injection layer, and thus, to the modification of the interface between the hole injection layer and the bottom electrode.