• Title/Summary/Keyword: Lift-off Test

Search Result 63, Processing Time 0.036 seconds

A Study on the Design and Fabrication of GHz Magnetic Thin Film Inductor Utilizing Co90Fe10/SiO2 Multilayer (Co90Fe10/SiO2 Multilayer를 이용한 GHz 자성박막 인덕터 설계 및 제작에 관한 연구)

  • 공기준;윤의중;진현준;박노경;문대철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5B
    • /
    • pp.985-991
    • /
    • 2000
  • In this paper, the optimum structure of 2GHz magnetic thin film planar inductor were designed and fabricated to reduce the inductor area and to maximize the inductance L and quality factor Q of the inductor. The optimum design was performed utilizing Co90Fe10 layer multilayered with SiO2 layers to avoid the eddy-current skin effect and considering new lumped element model. New magnetic thin film inductors operating at 2GHz were fabricated on a Si substrate utilizing photo-lithography and lift-off techniques. The frequency characteristics of L, Q, and impedance in more than fifty identical inductors were measured using an RF Impedance Analyzer(HP4291B with HP16193A test fixture). The self-resonant frequencies(SRF) of the inductors were measured by a Vector Network Analyzer(HP8510). The developed inductors have SRF of 1.8 to 2.3GHz, L of 47 to 68nH, and Q of 70 to 80 near 1GHz. Finally, high frequency, high performance, planar micro-inductor(area=30.8 x 30.8il$^2$) with maximized L and Q were fabricated succefully.

  • PDF

Eddy Current Testing of Weldment by Plus(+) Point Probe (Plus(+) Point Probe를 이용한 용접부 와전류검사)

  • Lee, Hee-Jong;Kim, Yong-Sik;Nam, Mim-Woo;Yoon, Byung-Sik;Kim, Seok-Kon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.426-432
    • /
    • 1999
  • A plus-point eddy current test(ECT) probe was developed to examine the defects on the welds of pumps, valves, and pipings which are the major components of the electric power plants, non-destructive evaluation (NDE) techniques for detecting and sizing the flaws were studied adapting this probe. Differential plus-point ECT probe is consists of two "I"-type coils crossed each other and has an advantage having a small influence on the sensitivity by lift-off variation to the conventional types of probe. The specimens with crack-like electro discharge machining(EDM) notches on the weld of type 304 stainless-steel were fabricated in order to evaluate the plus-point ECT probe response to the flaws. NDE techniques to detect and size the flaws and estimate the flaw type were established with this specimens.

  • PDF

Acoustic Loads Test of the Upper Stage of KSLV-I (소형위성발사체 상단부의 음향하중시험)

  • Chun, Young-Doo;Park, Jong-Chan;Chung, Eui-Seung;Park, Jung-Joo;Cho, Kwang-Rae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.224-227
    • /
    • 2007
  • This paper introduces the results of acoustic loads test conducted on the upper stage assembly of KSLV-I, which is the first Korea space launch vehicle. A launch vehicle and its payloads are subjected to severe acoustic pressure loading when they lift off and ascent during the transonic periods. Acoustic loadings are spreaded out broad frequncy-spectrum up to 10,000Hz. Acoustic loads are a primary source of structural random vibration of the upper stage and payloads. Therefore, in order to verify the structural integrity of the upper stage assembly of KSLV-I and the survivability of its components under severe random vibration environment, acoustic loads test is conducted in the high intensity acoustic chamber with 142dB (overall SPL). The results show the structural design and component random vibration specifications well meet with the environmental requirements.

  • PDF

Quality Evaluation of Resistance Spot Welding using Acoustic Emission (음향방출을 이용한 저항 점용접의 용접 품질평가)

  • Jo Dae-Hee;Rhee Zhang-Kyu;Park Sung-Oan;Cho Jin-Ho;Kim Bong-Gag;Woo Chang-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.4
    • /
    • pp.98-104
    • /
    • 2006
  • In this paper, for the purpose of investigation the acoustic emission(AE) behaviors during resistance spot welding process and tension test of spec steels. As the results present the resistance spot welding method that can get suitable welding qualities or structural integrity estimating method. The resistance spot welding process consists of several stages: set-down of the electrodes; squeeze; current flow; forging; hold time; and lift-off. Various types of AE signals are produced during each of these stages. For tensile-shear test and cross tensile test in resistance spot welded specimens, fracture pa 야 ems are produced: tear fracture; shear fracture; and plug fracture. Tensile-shear specimens strength appeared higher than cross tensile specimens one. In case of tensile-shear specimen happened tear fracture that crack happens in most lower plate. Also, in case of cross tensile specimens, upper plate and lower plate are detached perfect fracture was exposed increases a little as acting force is lower than ordinary welding condition. Therefore, the structure which is combined by resistance spot welding confirmed that welding design must attain so that shear stress may can interact mainly.

Effect of Lock Operations on Airtightness of Sliding and LS Window Systems (잠금장치 작동에 따른 미서기 및 LS 창호 시스템의 기밀성)

  • Park, Jong Jun;Yun, Yu Ra;Kim, Young Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.449-454
    • /
    • 2015
  • In this study, the effects of lock operations on the infiltration rates for the two window types sliding and lift sliding (LS) are investigated through experiment and simulation. The airtightness levels of the two window types-with locks both on and off-were measured according to the KS F 2292 Test method of airtightness that is used for windows and doors. The air-flow rates of both window types with the locks on for a pressure differential of 10 Pa are $1.98m^3/(m^2h)$ and $1.68m^3/(m^2h)$, respectively; with the locks off, the air-flow rates of the sliding and LS windows are $2.64m^3/(m^2h)$ and $5.83m^3/(m^2h)$, respectively, whereby the air-flow rates are 33% higher for sliding and 247% higher for LS. The air change per hour (ACH) was calculated using the ventilation-simulation software CONTAM. For the sliding window, the ACH changed from 0.45 to 0.57 when the lock was operated from on to off, representing an increase of 27%. For the LS window, the ACH changed from 0.29 to 0.81, showing an increase of 179%.

Field application of elasto-magnetic stress sensors for monitoring of cable tension force in cable-stayed bridges

  • Yim, Jinsuk;Wang, Ming L.;Shin, Sung Woo;Yun, Chung-Bang;Jung, Hyung-Jo;Kim, Jeong-Tae;Eem, Seung-Hyun
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.465-482
    • /
    • 2013
  • Recently, a novel stress sensor, which utilizes the elasto-magnetic (EM) effect of ferromagnetic materials, has been developed to measure stress in steel cables and wires. In this study, the effectiveness of this EM based stress sensors for monitoring of the cable tension force of a real scale cable-stayed bridge was investigated. Two EM stress sensors were installed on two selected multi-strand cables in Hwa-Myung Bridge, Busan, South Korea. Conventional lift-off test was conducted to obtain reference cable tension forces of two test cables. The reference forces were used to calibrate and validate cable tension force measurements from the EM sensors. Tension force variations of two test cables during the second tensioning work on Hwa-Myung Bridge were monitored using the EM sensors. Numerical simulations were conducted to compare and verify the monitoring results. Based on the results, the effectiveness of EM sensors for accurate field monitoring of the cable tension force of cable-stayed bridge is discussed.

Research on the Non-Contact Detection of Internal Defects in a Rail using Ultrasonic Waves (비접촉 초음파 방식의 철도레일 내부결함 검출에 관한 연구)

  • Han, Soon Woo;Cho, Seung Hyun;Kim, Joon Woo;Heo, Tae Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.617-625
    • /
    • 2012
  • Non-contact detection of internal defects in a rail using ultrasonic waves is discussed in this paper. Cracks in a rail may be a cause of a serious railway accident such as derailment if left undetected. Concurrent rail inspection method based on ultrasonic testing using piezoelectric transducers has several limitations as it should keep physical contact with the rail. This work suggests a non-contact detection of internal defects in a rail using ElectroMagnetic Acoustic Transducers (EMAT) which can produce and measure ultrasonic waves in a rail without any couplant. The EMATs for rail inspection are designed and fabricated and their working performance is verified through a series of experiments on various types of internal defects in test rails. The effect of lift-off between the transducers and the rail on the generated signals is also discussed.

  • PDF

Lift-Off Voltage and Partial Discharge Characteristics of Free Conducting Particles in GIS (GIS 내 금속입자의 부상전압과 부분방전특성 연구)

  • Yoon, Jin-Yeol;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1684-1686
    • /
    • 1998
  • Gas Insulated Switchgear(GIS) acts as an indispensible part in power transmission network. In order that GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, using the EHV test chamber, partial discharge quantity in GIS was measured when free conducting particles initiate to discharge for providing fundamental data for the purpose of developing predictive diagnosis technology on site GIS.

  • PDF

Vibro-acoustic Analysis of Simplified Satellite Model by Using the Statistical Energy Analysis (단순화된 위성체의 통계적 에너지 해석법을 이용한 음향-진동 연성 해석)

  • C. H. Jeong;J. G. Ih;S. M. Moon;Kim, H. B.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.371.1-371
    • /
    • 2002
  • At lift-off, the jet noise of launch vehicle produces a severe acoustic environment and the loads induced by the acoustic pressure may be damaging to paylaod and equipments. Prediction of the acoustic environment is needed to support the design and test-qualification of components. Currently, such a high frequency problem is usually dealt with by using the SEA, of which the assumptions match reasonably well with the vibro-acoustic condition of system. (omitted)

  • PDF

Shock Vibration Control of Hard-Disk Drive Using Coupled Shock Spectrum Analysis in Time-Frequency Domain (시간-주파수 영역에서의 연성 충격 스펙트럼 분석을 통한 하드디스크 드라이브의 충격진동 제어 (현장개발사례: SAMSUNG HDD 'SPINPOINT V40/P40 SERIES'))

  • Han, Yun-Sik;Kang, Seong-Woo;Oh, Dong-Ho;Hwang, Tae-Yeon;Son, Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1111-1116
    • /
    • 2001
  • A transient T-F(time-frequency) signal processing technique is applied to a tilt drop and a linear shock test rigs for identification of shock characteristics of hard disk drive (HDD). The T-F technique essentially tracks the shock characteristics of pivot point response as well as head slap and lift-off phenomena. From the T-F analysis result, the shock characteristic in HDD is modeled by the two degree of freedom coupled-dynamic system, which consists of actuator arm and suspension. As shock designing tool, the maximax shock response spectrum is employed for prediction of shock performance. Finally, the shock control technique is tested with newly designed actuator arm and suspension. Experimental head slap test result shows that the shock performance is much higher with the new shockproof designed model than the current model

  • PDF