• 제목/요약/키워드: Lifetime Assessment

검색결과 223건 처리시간 0.026초

화력발전소용 0.5Cr 0.5Mo 0.25V 강 곡관배관의 크리프 손상평가 (Assessment of Creep Damage on a High Temperature Pipe Bend of 0.5Cr0.5Mo0.25V Ferritic Steel for Thermal Power Plant)

  • 현중섭;허재실;김봉수
    • 한국정밀공학회지
    • /
    • 제27권3호
    • /
    • pp.127-134
    • /
    • 2010
  • Components in thermal power plants are subjected to service conditions under which creep damages take place causing material exhaustion. Comprehensive creep damage investigations have been performed on a 0.5Cr0.5Mo0.25V pipe bend which had been taken out of service after 117,603h and 501 start-ups because of severe cracks. The propagation of creep damage in a long term exposed pipe bend has been analysed by the replication, Indentation and hardness tests. Also, Calculation of creep lifetime has been investigated in order to verify actual lifetime of a damaged pipe bend. By measuring diametrical expansion, Accumulated creep strain and creep strain rate were calculated. Calculated results of creep lifetime on the Larson-Miller Parameter method are good agreement with actual service-exposed hour.

무은 솔더의 신뢰성 평가에 관한 연구 (A Study on Reliability Assessment of Ag-free Solder)

  • 김종민;김기영;김강동;김선진;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권2호
    • /
    • pp.109-116
    • /
    • 2013
  • The solder is any of various fusible alloys, usually tin and lead, used to join metallic parts that provide the contact between the chip package and the printed circuit board. Solder plays an important role of electrical signals to communicate between the two components. In this study, two kinds of Ag-free solder as sample is made to conduct the thermal shock test and the high humidity temperature test. Low resistance is measured to estimate crack size of solder, using daisy chain. The low speed shear test is also performed to analyze strength of solder. The appropriate degradation model is estimated using the result data. Depending on the composition of solder, lifetime estimation is conducted by adopted degradation model. The lifetime estimated two kinds of Ag-free solder is compared with expected lifetime of Sn-Ag-Cu solder. The result is that both Ag-free composition are more reliable than Sn-Ag-Cu solder.

생애 위험도기반 건축물의 설계단계 생애주기비용 분석 방법 (Life Cycle Cost Analysis for Design of Buildings based on the Lifetime Risk)

  • 백병훈;조중연
    • 한국건설관리학회논문집
    • /
    • 제15권3호
    • /
    • pp.113-119
    • /
    • 2014
  • LCC 분석은 건축물의 설계단계 뿐만 아니라 유지관리 단계에서의 보수 보강 또는 교체에 대한 최적 의사결정의 도구로서 이론적으로나 실무적으로 각광을 받고 있는 분석 방법이다. 이는 초기 투자비용의 효율성을 극대화 하고 유지관리를 통한 구조물 사용성의 효율적 증대를 극대화하는 노력의 일환으로 최근 건축물의 설계 및 유지관리 시 LCC 분석효과의 실질적인 적용이 요구되어 지고 있다. 따라서 본 논문은 일반적인 분석기법에 그치고 있는 기존 LCC 연구를 생애위험도를 고려한 LCC분석을 통해 설계단계 최적 의사결정을 위한 새로운 분석 방법론을 도출하였다.

지수 수명분포에 대한 Bayesian 합격판정 샘플링계획의 개발 및 비교에 관한 연구 (Development and Comparisons of Bayesian Acceptance Sampling Plans for the Exponential Lifetime Distribution)

  • 정현석;진휘철;염봉진
    • 대한산업공학회지
    • /
    • 제20권1호
    • /
    • pp.15-25
    • /
    • 1994
  • The Bayesian approach to reliability acceptance sampling has several advantages over the non-Bayesian approach. For instance, the former usually requires less amount of testing time and smaller sample sizes than the latter. In this article, a Bayesian acceptance sampling plan(ASP) based on a failure-free period life test is developed under the assumption of exponential lifetime distribution, and is compared with the corresponding Bayesian hybrid ASP in terms of the expected completion time. It is found that the proposed ASP tends to have a smaller expected completion time than the Bayesian hybrid ASP as the prior assessment of the reliability of a lot becomes optimistic, and vice versa. Tables of failure-free period Bayesian ASP's are also included.

  • PDF

입환기관차의 LCC 평가분석 (Life-Cost-Cycle Evaluation Analysis of the Shunting Locomotive)

  • 배대성;정종덕
    • 한국철도학회논문집
    • /
    • 제8권3호
    • /
    • pp.260-266
    • /
    • 2005
  • The deterioration of a shunting locomotive was characterized for the lifetime assessment. The locomotive has been used for shunting works in steel making processes, and in this investigation, various types of technical evaluation methods for the locomotive parts were employed to assess the current deterioration status and to provide important clue for lifetime prediction. Unlike other rolling stocks in railway applications, the diesel shunting locomotive is composed of major components such as diesel engine, transmission, gear box, brake system, electronic devices, etc., which cover more than 70 percent of the total price of the locomotive. Therefore, in this paper, each part of major components in the diesel locomotive was analyzed in terms of the degree of deterioration. The lift-cycle-cost (LCC) analysis was performed based on the maintenance and repair history as compared with economical cost to provide the cost-effective prediction, i.e., to assess either repair for reuse or putting the locomotive out of service based on cost-effective calculation.

승강기용 방진고무부품 특성 및 사용수명 평가 (Useful Lifetime Evaluation of Rubber Component for Elevator Cabin)

  • 우창수;박현성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.576-580
    • /
    • 2008
  • Rubber material properties and useful life evaluation are very important in design procedure to assure the safety and reliability of the rubber components. In this paper, the evaluation of characteristics and useful life prediction of rubber component for elevator cabin were experimentally investigated. The material test and accelerated heat-aging test were carried. Rubber material constants were obtained by curve fittings of simple tension, pure shear and bi-axial tension test data. Heat aging test results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. By using the rubber material and component test several useful life prediction equations for rubber component were proposed. Predicted useful life of rubber component for elevator cabin agreed fairly with the experimental lives.

  • PDF

입환기관차의 LCC 평가분석 (Life-Cost-Cycle Evaluation Analysis of the Shunting Locomotive)

  • 정종덕;김정국;편장식;김필환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.551-556
    • /
    • 2004
  • The deterioration of a shunting locomotive was characterized for the lifetime assessment. The locomotive has been used for shunting works in steel making processes, and in this investigation, various types of technical evaluation methods for the locomotive parts were employed to assess the current deterioration status and to provide important clue for lifetime prediction. Unlike other rolling stocks in railway applications, the diesel shunting locomotive is composed of major components such as diesel engine, transmission, gear box, brake system, electronic devices, etc., which cover more than 70 percent of the total price of the locomotive. Therefore, in this paper, each part of major components in the diesel locomotive was analyzed in terms of the degree of deterioration. The life-cycle-cost (LCC) analysis was performed based on the maintenance and repair history as compared with economical cost to provide the cost-effective prediction, i.e., to assess either repair for reuse or putting the locomotive out of service based on cost-effective calculation.

  • PDF

유한요소법에 의한 부식을 고려한 전동차 차체의 강도평가 (The Structural Strength Assessment of Corroded Electric Rail Car Body Structure by FEM)

  • 김선용;구병춘;임충환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.350-355
    • /
    • 2005
  • All the facility, the structure and the rolling stock have limited life so after starting use, we must decide disuse or use when it exeeds the lifetime. Currently the subway which exeeds the lifetime appeared in our country. Structural members of rolling stock structures were occurred corrosion after passage of time and It gives a many effect in the structure strength. In this study, it accomplished a structural analysis which use FEM for the No.2 subway line which operated currently, and it investigated the structural strength change which it follows with dimension change of structural members due to corrosion

  • PDF

원자력발전소 케이블의 건전성 평가방법 및 수명관리방안에 관한 고찰 (A Study on Integrity Assessment and Lifetime Management of Cables in the Containment of the Nuclear Power Plant)

  • 이창수;최미령;진태은;임우상;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.73-75
    • /
    • 2005
  • A number of the power cables arc installed in the containment of the nuclear power plant. According to the IEEE Standard 835, the calculation of the temperature rise shows the operation possibility of power cables in the containment. In this paper, we expect the integrity of the power cables by using the calculation of the temperature rise and the development of the lifetime extension of the cables.

  • PDF

석유화학단지의 휘발성 유기화합물로 인한 인체 위해도 평가에 관한 연구 (A Study on the Health Risk Assessment of Volatile Organic Compounds in a Petrochemical Complex)

  • 이진홍;김윤신;류영태;유인석
    • 한국대기환경학회지
    • /
    • 제13권4호
    • /
    • pp.257-267
    • /
    • 1997
  • This study focuses on the health risk assessment of airborne volatile organic compounds (VOCs) in a petrochemical complex, with several emphases on a risk assessment method. The first emphasis is on the importance of hazard identification to determine the likely carcinogenic potential of a VOC. Without considering this type of information, a direct comparison of the carcinogenic risks of two pollutants is meaningless. Therefore, wer suggest that this type of information be prepared and be listed with the estimate of cancer risk in parallel. The second emphasis is on the selection of a better dose-response model to estimate unit risk or cancer potency factor of a carcinogenic VOC. Finally, probilistic risk assessment method is discussed and recommended to use within a comparison of conventional point-estimate method. A health risk assessment has also been carried out. For non-carcinogenic risk, even the highest hazard index for carbon tetrachloride is estimated to be less than 1 with the other VOCs less than 0.03. However, the lifetime cancer risk from the inhalation of airborne VOCs is estimated to be about $2.6 \times 10^{-4}$ which is higher than the risk standard of $10^{-6}$ or even $10^{-5}$. Therefore, the investigation into domestic petrochemical complexes should be strengthened to obtain more fine long-term airborne VOC data.

  • PDF