• 제목/요약/키워드: LiBr수용액

검색결과 42건 처리시간 0.023초

증발기 열원으로 태양열을 이용하며 LiSCN+LiBr 수용액을 사용하는 흡수식 2중효용 난방시스템의 열역학적 해석 (Thermodynamic Analysis of a Double-Effect Absorption Heating System Using Water-LiBr-LiSCN Solution with Solar Evaporator Heating)

  • 원승호
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.27-35
    • /
    • 2005
  • In this paper, a thermodynamic analysis was performed to provide design data for a double-effect absorption heating system with water-LiBr-LiSCN mixture which utilizes solar energy as evaporator heat source. In addition, a comparative study of the water-LiBr-LiSCN mixture against the water-LiBr pair was conducted by a computer simulation. The computer simulation is based on mass, material and heat balance equations for each part of the system. Coefficients of performance and flow ratios for effects of different operating temperatures are investigated. It is found that the heating COP is higher for the water-LiBr-LiSCN mixture than for the water-LiBr pair, and FR is lower for the former.

$LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 LiBr 농도의 영향 (The Effect of LiBr Concentration on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids)

  • 임우조;정기철
    • 한국가스학회지
    • /
    • 제5권4호
    • /
    • pp.33-39
    • /
    • 2001
  • 흡수식냉동기의 작동매체로 사용되고 있는 LiBr수용액 중에서 각 구성재료인 일반구조용 압연강재, 동 및 동합금재인 Ai-Ni bronze의 부식거동에 관한 연구를 하기 위하여, 여러 가지 농도의 LiBr 수용액 중에서 각 재료에 대한 분극실험을 실시하여 부식거동을 고찰한 결과 다음과 같은 결론을 얻었다. 1) 수용액의 LiBr 농도가 증가할수록 각 재료의 분극저항은 낮아지고, 개로전위는 비전 위화되면서 부식전류밀도는 높게 배류된다. 2) 일반구조용 압연강재의 개로전위는 동 및 Al-Ni bronze의 개로전위보다 비전위화되면서 부식전류밀도는 더 높게 배류된다. 3) 동 및 Al-Ni bronze에 대한 $62\%$ LiBr 수용액 중에서의 양극분극은 활성태로 지속되지만, 천연해수 중에서의 양극분극은 활성태가 지속되다가 부동태화전류가 나타난다.

  • PDF

교차 적층된 파형 액체 제습 소자 (Celdek)에서 LiCl과 LiBr 수용액의 제습 성능 비교 (Comparison of the Dehumidification Performance Between LiCl and LiBr in a Liquid Desiccant Dehumidifying Element Having Criss-Cross Sinusoidal Channels (Celdek))

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.27-34
    • /
    • 2018
  • 최근 들어 공기의 제습에 액체 제습제를 사용하는 방법이 각광을 받고 있다. LiCl과 LiBr은 우수한 열물성으로 인하여 액체 제습 시스템에 널리 사용되고 있다. 본 연구에서는 LiCl과 LiBr 수용액을 사용하여 상용 Celdek 소자의 제습 성능을 실험하였다. 실험은 입구 건습구 온도를 $35^{\circ}C/28^{\circ}C$로 유지하고 전방 풍속을 2.0 m/s에서 4.0 m/s로 변화시키며 수행되었다. 수용액의 입구 온도와 농도는 $20^{\circ}C$, 50%, 수용액의 순환량은 50 kg/h로 유지하였다. 실험 결과 제습량은 풍속이 증가할수록 증가하였다. 또한 LiCl의 제습 성능은 LiBr보다 평균 27% 크게 나타났다. 이는 LiCl의 포화 절대 습도가 LiBr의 포화 절대습도보다 작기 때문이다. 반면 LiBr의 압력 손실은 LiCl보다 평균 12% 크게 나타났다. 한편 LiCl 과 LiBr의 Sherwood 수는 비교적 잘 일치하였다. 이로부터 제습제가 Sherwood 수에 미치는 영향은 미미함을 알 수 있다. 기존 상관식들은 본 실험의 Sherwood 수를 현저히 높게 예측하였다.

Lithium Bromide 수용액중에서 연신된 견의 구조와 물성 (Structure and Mechanical Properties of Silk Fiber Stretched in Aqueous Solution of LiBr)

  • 김동건;최진협;소서효
    • 한국잠사곤충학회지
    • /
    • 제37권1호
    • /
    • pp.33-38
    • /
    • 1995
  • 견 fibroin을 8M LiBr 수용액에 침지하여 연신처리에 의한 견의 구조와 물성변화를 시험해 보았다. 1. 연사의 역학적 성질은 8M LiBr 수용액의 처리온도 상승에 따라서 강도와 신도는 증가하나 Young's율은 감소하는 경향이었다. 8$0^{\circ}C$ 처리의 X선회절에 있어서는 염축에 의해 분자배향은 흐트러지나 SilkII형의 결정구조는 변하지 않았다. 2. 8M LiBr수용액을 사용하여 8$0^{\circ}C$에서 1시간 처리하면 160%정도 연신이 가능하며 고연신시의 역학적 성질에 있어서는 강도와 Young's율은 증가하고 신도는 감소하였으나 X선회절에서는 연신율의 증가와 함께 결정이 고배향화되는 경향이었다. 3. DSC의 시차열 Thermogram에서 무처리의 연사와 8M LiBr 수용액에 처리되어진 미연신의 연사사이에는 열분해거동이 다른 것이 관찰되었으며 열분해 최대 Peak점의 온도는 연신율의 증가에 따라 조금씩 고온쪽으로 이동함으로써 X선회절사진의 결과와 일치하고 있다.

  • PDF

태양열을 증발기 열원으로 사용($20{\sim}40^{\circ}C$범위)하며 LiSCN+LiBr 수용액을 사용하는 흡수식 2중효용 난방시스템의 열역학적 해석 (Thermodynamic Analysis of a Double-Effect Absorption Heating System Using Water-LiBr- LiSCN Solution As $20{\sim}40^{\circ}C$ Range Solar Evaporator Heating)

  • 원승호
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.73-81
    • /
    • 2006
  • In this paper, with water-LiBr-LiSCN mixture which utilizes solar energy as mid temperature range evaporator heat source, a thermodynamic analysis was performed to provide design data for a double-effect absorption heating system. A comparative study of the water-LiBr-LiSCN mixture against the water-LiBr pair was conducted by a computer simulation. The computer simulation is based on mass, material and heat balance equations for each part of the system. Coefficients of performance and flow ratios for effects of different operating temperatures are investigated. It is found that the heating COP is higher for the water-LiBr-LiSCN mixture than for the water-LiBr pair, and FR is lower for the former.

공냉형 흡수식 냉방 시스템에서 LiBr 수용액의 과열도가 증기 흡수에 미치는 영향 (Effect of degree of superheat of LiBr aqueous solution on the vapor absorption process for an air-cooled absorption cooling system)

  • 김선창;오명도;이재헌
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.122-133
    • /
    • 1997
  • Numerical analysis using finite volume method has been carried out to examine the effect of degree of superheat of LiBr aqueous solution on heat and mass transfer occurred in absorption process. According to the result of this study, it was found that refrigerant vaper was generated at the entrance region of absorber when LiBr aqueous soltion was superheated. As the degree of superheat increases, heat transfer rate increases and vapor absorption rate decreases. The increase in averaged Nusselt and Sherwood numbers could be found as film Reynolds number increases. The larger the degree of superheat, the greater the averaged Nusselt and Sherwood numbers.

  • PDF

LiBr 수용액을 이용한 수평관 유하액막 증발의 촉진관 전열향상 특성 (Heat Transfer Enhancement Characteristics for Falling-Film Evaporation on Horizontal Enhanced Tubes with Aqueous LiBr Solution)

  • 김동관;김무환
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1267-1276
    • /
    • 1998
  • Falling-film evaporation experiments with aqueous lithium bromide (LiBr) solution were performed to investigate the heat transfer characteristics of enhanced copper tubes. Enhanced tubes (a knurled tube, a spirally grooved tube, and a tube coated with $20{\mu}m$ aluminum particles) and a bare tube were selected as test specimens. Averaged evaporation fluxes of water were obtained from horizontal tubes with various film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. The enhanced performance of steam generation was compared between tubes with varying parameters. The knurled tube geometry showed the most excellent performance among the tubes tested. The specified enhanced tubes were more useful for generating steam on a low grade heat source such as waste heat.

계면활성제 첨가시 수평 냉각관 외부를 흘러내리는 LiBr수용액의 열 및 물질전달 특성에 관한 연구 (A Study on Heat and Mass Transfer Characteristics of LiBr-$H_2$O Solution with a Sufactant Flowing over a Cooled Horizontal Tube)

  • 김경희;설신수;이상용
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.341-349
    • /
    • 2002
  • Heat and mass transfer characteristics of a surfactant-added LiBr-$H_2O$ solution flowing over a single horizontal tube were examined experimentally. The parameters considered were surfactant (2-ethyl-1-hexanol) concentration, solution temperature at the top of the tube and absorber pressure. Even with an amount of the surfactant below the solubility limit, heat and mass transfer performances were enhanced tremendously. The Nusselt and Sherwood numbers increased by about 70% and 340%, respectively, when 10 ppm of the surfactant was added. However, an excess amount of the surfactant in the solution did not bring a further enhancement. The absorption performance deteriorated when the non-condensable gases were extracted from the system (by a vacuum pump) since the vaporized surfactant was also extracted during the process. Therefore, it is desirable to add a sufficient amount of the surfactant (more than 10 ppm) to maintain high performance of absorption.

하수처리수이용 신용액 흡수식 냉동기의 성능해석 (Performance Analysis of New Working Solution for Absorption Refrigeration Machine using Treated Sewage)

  • 권오경;유선일;윤정인
    • 에너지공학
    • /
    • 제7권2호
    • /
    • pp.231-240
    • /
    • 1998
  • CFC계 냉매에 의한 지구환경문제 야기, 여름철 피크전력의 증가뿐만 아니라 열회수 시스템에서의 손실로 인하여 고성능 흡수냉동시스템의 개발은 이 문제를 해결할 수 있는 유망한 방법중의 하나이다. 하수처리수를 이용한 흡수식 냉동시스템은 환경보호와 에너지 보존의 측면에서 유용하다. 본 연구에서는 2중효용 병렬 및 직렬방식에 대한 사이클 시뮬레이션 해석을 수행하였다. 신작동매체로 LiBr+LiI+LiCl+LiNO3 용액을 선택하였다. 이 연구의 주된 목적은 흡수기와 응축기의 냉각수로써 하수처리수를 효과적으로 이용할 수 있는 가능성을 평가하는 것과 2중효용 병렬과 직렬방식에 영향을 미치는 신작동매체의 특성을 파악하고 최적설계조건을 찾고자 하는 것이다. 본 연구에서 사이클 시뮬레이션을 통하여 신작동매체를 사용하는 흡수식 냉동기의 특성을 파악했으며 이를 기존의 LiBr 수용액을 사용하는 흡수식 냉동기와 비교평가하였다. 신작동매체를 이용한 흡수식 냉동기는 LiBr 수용액을 사용하는 경우보다 COP의 향상과 시스템의 소형화가 가능하다는 것을 알 수 있었다.

  • PDF

좁은 휜이 달린 경사면을 흐르는 리튬브로마이드 수용액 흡수기에서의 열 및 물질전달 (Coupled Heat and Mass Transfer in Absorption of Water Vapor into LiBr-$H_2O$ Solution Flowing over a Finned Inclined Surface)

  • 조은준;서태범
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.860-867
    • /
    • 2001
  • Absorption of water vapor into LiBr-$H_2O$ O solution flowing over a finned inclined surface is numerically investigated. The momentum, energy, and diffusion equation are numerically solved using a finite difference method. The four different shapes of the wall surfaces are considered to find the best surface for absorption assuming that the wall temperature and the surface tension are constant. The effects of the fin interval and Reynolds number are investigated. Based on the numerical results, it is known that the parabolic surface shows better absorption performance than the other surfaces, and that water vapor absorption increases gradually with decreasing the fin interval.

  • PDF