• Title/Summary/Keyword: Level measurement

Search Result 4,867, Processing Time 0.044 seconds

A Study on the Automatic Level Measurement for Land Leveling (경지 균평 작업을 위한 자동 표고 측정에 관한 연구)

  • 김종안;김수현;곽윤근
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.269-278
    • /
    • 1997
  • An automatic level measurement system was developed to level the land fer direct seeding of rice. A laser transmitter/receiver set was used to measure land-level. The inclination error occurred in level measurement on irregular land surface could be compensated by attaching rotating mass. The level measuring experiments were performed on three kinds of different shapes(step, random, sine). This system could accurately measure step level of which amplitude was 40mm in 0.5s, random level change within $\pm$ 5mm maximum measurement error, and sine level change of which spatial frequency was 0.5m-1. To verify performance of the inclination error compensation system, frequency transfer function(acceleration input vs. inclination error) was computed by spectral analysis. The inclination error was decreased about 20㏈ by error compensation system.

  • PDF

RADAR level measurement in Joule heated ceramic melter: A novel technique

  • Suneel, G.;Mahashabde, Mukesh;Borkotoky, Ritusmita;Sharma, Nitin Kumar;Pradeep, M.P.;Gayen, J.K.;Pimparkar, H.R.;Ravi, K.V.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1176-1180
    • /
    • 2021
  • The current study relates to RADAR (RAdio Detection and Ranging) application for level measurement of vitrified radioactive liquid nuclear waste. The vitrification of radioactive liquid waste is carried out in special equipment called 'Melters'. The study is directed towards the design and frequency modulation used in the level measurement of vitrified waste. More specifically, the RADAR design and frequency used for level measurement in a melter. This level measurement technique can also be used for dynamic vitrification process and can be used to measure the level variations without using any external medium/material and using only electromagnetic waves. Also, this technique is durable and accurate even under the high radioactive environment present inside the melter.

Liquid level measurement system using capacitive sensor and optical sensor

  • Shim, Joonhwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.778-783
    • /
    • 2013
  • Measurement of liquid level in storage and processing vessels, tanks, wells, reservoirs and hoppers is commonly needed. The several different ways to measure the liquid level of oil or water tank have been provided such as an electrostatic capacity, a supersonic waves and an optical science etc. In the study, we have constructed the stable and efficient measurement system to measure the level of liquid at real-time and to get accurate measurement of the maximum and minimum level of the tank. For this purpose, we suggest double sensing methods by adopting both capacitive and optical sensing. The experimental results, presented in this paper, illustrate the effectiveness of the proposed method under different sensing methods.

Study on Measurement of Flood Risk and Forecasting Model (홍수 위험도 척도 및 예측모형 연구)

  • Kwon, S.H.;Oh, H.S.
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.1
    • /
    • pp.118-123
    • /
    • 2015
  • There have been various studies on measurements of flood risk and forecasting models. For river and dam region, PDF and FVI has been proposed for measurement of flood risk and regression models have been applied for forecasting model. For Bo region unlikely river or dam region, flood risk would unexpectedly increase due to outgoing water to keep water amount under the designated risk level even the drain system could hardly manage the water amount. GFI and general linear model was proposed for flood risk measurement and forecasting model. In this paper, FVI with the consideration of duration on GFI was proposed for flood risk measurement at Bo region. General linear model was applied to the empirical data from Bo region of Nadong river to derive the forecasting model of FVI at three different values of Base High Level, 2m, 2.5m and 3m. The significant predictor variables on the target variable, FVI were as follows: ground water level based on sea level with negative effect, difference between ground altitude of ground water and river level with negative effect, and difference between ground water level and river level after Bo water being filled with positive sign for quantitative variables. And for qualitative variable, effective soil depth and ground soil type were significant for FVI.

Ship Radiated Noise Measurement Methods and Accuracy Analysis (선박 방사소음의 측정방법 및 정확도 해석)

  • Lee, Phil-Ho;Yoon, Jong-Rak
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

A Study on the Development of the Automatic Level Measurement System (자동 표고 측정 장치 개발에 관한 연구)

  • 김종안;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.756-760
    • /
    • 1997
  • In this research, the automatic level measurement system used in land leveling was developed. By using a laser transmitter and a receiver as measuring equipments, level was measured automatically. The driving part of this system was composed of stepping motor, timing belt and pulley. It drived the laser receiver to track laser beam generated form the laser transmitter. The level measuring experiments were performed about three level change shapes (step, random, sine). This system could measure step level change of which amplitude was 40mm in 0.5s, random level change within .+-. mm, maximum measurement error. In case of sine level change, experiment was executed with varying the spatial frequency of level change. As a result, this system was able to measure sine level change of which spatial frequency was 0.5m $^{-1}$ accurately.

  • PDF

Development of Automatic Water Level Measurement System for the Irrigation Reservoir - Study on Low Power and Remote Controlled Water Level Measurement System - (농업저수지 자동 수위관측기 개발 - 저전력 원격제어 수위관측기 중심 -)

  • Kim, Jin-Taek;Joo, Uk-Jong;Choi, Seung-Chul
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.491-494
    • /
    • 2003
  • An Automatic Water Level Measurement System has been developed in this study. It has the characteristics that it use lower power and solar power and it has the ability of sending data and remote-controlled by wireless MODEM this system was set up in the experimental site and was tested. Also, the management system for the water level data has been developed and will be used by instruments administrating reservoirs.

  • PDF

An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test (실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구)

  • Kim, Hang;Park, Hyeon Ku;Ku, Hee Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.

A Method on the Improvement of the Minimum Detection Distance of the Remote Measurement Level Meter (원격 측정 레벨계의 최소 탐지거리 성능 개선 방법)

  • Park, Dongkun;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.535-543
    • /
    • 2018
  • Recently, level meters have been associated with the safety and maintenance of industrial sites and require a wide measurement range. Generally, to ensure the measurement range of the level meter, the measurement environment is improved to reduce the noise or to compensate the distortion of the signal through signal processing. The noise of FMCW (Frequency Modulated Continuous Wave) radar level meter or the distortion of the signal affects the near region characteristics of the level gauge, resulting in a reduction of the minimum detection distance. In this paper, an equalizer filter considering characteristics of window function and bit spectrum is applied to remove the noise in the near region of the level meter to improve the minimum detection distance performance and to improve the measurement reliability in the vicinity of the level meter, which is relatively difficult to detect, we want to improve the detection range.

Development of the Ultrasonic Method for Two-Phase Mixture Level Measurement

  • Lee, Dong-Won;No, Hee-Cheon;Song, Chul-Wha;Jeong, Moon-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.124-124
    • /
    • 1999
  • An ultrasonic method is developed for the measurement of the two-phase mixture level in the reactor vessel or steam generator. The ultrasonic method is selected among the several non¬nuelear two-phase mixture level measurement methods through two steps of selection procedure. A commercial ultrasonic level measurement method is modified for application into the high temperature, pressure, and other conditions. The calculation method of the ultrasonic velocity is modified to consider the medium as the homogeneous mixture of air and steam. and to be applied into the high temperature and pressure conditions. The cross-correlation technique is adopted as a detection method to reduce the effects of the attenuation and the dif.JUsed reflection caused by suface fluctuation. The waveguides are developed to reduce the loss of echo and to remove the effects of obstructs. The present experimental study shows that the developed ultrasonic method measures the two-phase mixture level more accurately than the conventional methods do.

  • PDF