• Title/Summary/Keyword: Level Plate

Search Result 931, Processing Time 0.032 seconds

Evaluation of Dimensions of Kambin's Triangle to Calculate Maximum Permissible Cannula Diameter for Percutaneous Endoscopic Lumbar Discectomy : A 3-Dimensional Magnetic Resonance Imaging Based Study

  • Pairaiturkar, Pradyumna Purushottam;Sudame, Onkar Shekhar;Pophale, Chetan Shashikant
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.414-421
    • /
    • 2019
  • Objective : To evaluate 3-dimensional magnetic resonance imaging (MRI) of Kambin's safe zone to calculate maximum cannula diameter permissible for safe percutaneous endoscopic lumbar discectomy. Methods : Fifty 3D MRIs of 19 males and 31 females (mean, 47 years) were analysed. Oblique, axial and sagittal views were used for image analysis. Three authors calculated the inscribed circle (cannula diameter) individually, within the neural (original) and bony Kambin's triangle in oblique views, disc heights on sagittal views and root to facet distances at upper and lower end plate levels on axial views and their averages were taken. Results : The mean root to facet distances at upper end plate level measured on axial sections increased from $3.42{\pm}3.01mm$ at L12 level to $4.57{\pm}2.49mm$ at L5S1 level. The mean root to facet distances at lower end plate level measured on axial sections also increased from $6.07{\pm}1.13mm$ at L12 level to $12.9{\pm}2.83mm$ at L5S1 level. Mean maximum cannula diameter permissible through the neural Kambin's triangle increased from $5.67{\pm}1.38mm$ at L12 level to $9.7{\pm}3.82mm$ at L5S1 level. The mean maximum cannula diameter permissible through the bony Kambin's triangle also increased from $4.03{\pm}1.08mm$ at L12 level to $6.11{\pm}1mm$ at L5S1 level. Only 2% of the 427 bony Kambin's triangles could accommodate a cannula diameter of 8mm. The base of the bony Kambin's triangle taken in oblique view (3D MRI) was significantly higher than the root to facet distance at lower end plate level taken in axial view. Conclusion : The largest mean diameter of endoscopic cannula passable through "bony" Kambin's triangle was distinctively smaller than the largest mean diameter of endoscopic cannula passable through "neural" Kambin's triangle at all levels. Although proximity of exiting root to the facet joint is always taken into consideration before PELD procedure, our 3D MRI based anatomical study is the first to provide actual maximum cannula dimensions permissible in this region.

Biomechanical Analysis of Biodegradable Cervical Plates Developed for Anterior Cervical Discectomy and Fusion

  • Cho, Pyung Goo;Ji, Gyu Yeul;Park, Sang Hyuk;Shin, Dong Ah
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1092-1099
    • /
    • 2018
  • Study Design: In-vitro biomechanical investigation. Purpose: To evaluate the biomechanical effects of the degeneration of the biodegradable cervical plates developed for anterior cervical discectomy and fusion (ACDF) on fusion and adjacent levels. Overview of Literature: Biodegradable implants have been recently introduced for cervical spine surgery. However, their effectiveness and safety remains unclear. Methods: A linear three-dimensional finite element (FE) model of the lower cervical spine, comprising the C4-C6 vertebrae was developed using computed tomography images of a 46-year-old woman. The model was validated by comparison with previous reports. Four models of ACDF were analyzed and compared: (1) a titanium plate and bone block (Tita), (2) strong biodegradable plate and bone block (PLA-4G) that represents the early state of the biodegradable plate with full strength, (3) weak biodegradable plate and bone block (PLA-1G) that represents the late state of the biodegradable plate with decreased strength, and (4) stand-alone bone block (Bloc). FE analysis was performed to investigate the relative motion and intervertebral disc stress at the surgical (C5-C6 segment) and adjacent (C4-C5 segment) levels. Results: The Tita and PLA-4G models were superior to the other models in terms of higher segment stiffness, smaller relative motion, and lower bone stress at the surgical level. However, the maximal von Mises stress at the intervertebral disc at the adjacent level was significantly higher in the Tita and PLA-4G models than in the other models. The relative motion at the adjacent level was significantly lower in the PLA-1G and Bloc models than in the other models. Conclusions: The use of biodegradable plates will enhance spinal fusion in the initial stronger period and prevent adjacent segment degeneration in the later, weaker period.

Microbial Hazard Analysis of the Manufacturing Processes for Frozen Korean Cold Noodle, Naengmyeon (냉동 냉면류의 제조공정별 미생물학적 위해요소 평가)

  • Kim, YuJung;Kim, HyeJin;Lim, Youngeun;Yang, HuiJie;Park, Seulgi;Cheong, Jin-Sook;Om, Ae-Son
    • Journal of the FoodService Safety
    • /
    • v.3 no.1
    • /
    • pp.38-44
    • /
    • 2022
  • This study investigated the microbiological hazards in the manufacturing processes of Naengmyeon. Sanitary indicative bacteria, such as aerobic plate counts and coliforms as well as pathogenic bacteria, were examined from raw materials, manufacturing processes, working area, 17 utensils and equipment. The aerobic plate counts for raw materials and arrowroot starch estimated as 0.77±0.68~5.02±0.28 and 5.02±0.28 log CFU/g, respectively. Coliforms were detected from wheat flour, buckwheat flour, and potato starch. Staphylococcus aureus was detected to be 0.61±1.06 log CFU/g in wheat flour and 0.20±0.35 log CFU/g in buckwheat flour. During the manufacturing process, aerobic plate counts for kneading process were 4.54±0.34 log CFU/g. But after the press out and heat process, contamination of aerobic plate counts and coliforms decreased and remained at a low level until the release process. Aerobic plate counts before washing disinfection of screw were 3.28±0.62 log CFU/100 cm2, the level of which was high in utensils and equipment that had contact with employees or water. These results represent not only an important indicator for the hygienic level but also a scientific basis for analyzing biological hazards, which lead to the introduction of HACCP for the production of safe and hygienic cold noodles processed by manufacturers.

Vibroacoustic response of thin power law indexed functionally graded plates

  • Baij Nath Singh;Vinayak Ranjan;R.N. Hota
    • Steel and Composite Structures
    • /
    • v.50 no.3
    • /
    • pp.299-318
    • /
    • 2024
  • The main objective of this paper is to compute the far-field acoustic radiation (sound radiation) of functionally graded plates (FGM) loaded by sinusoidally varying point load subjected to the arbitrary boundary condition is carried out. The governing differential equations for thin functionally graded plates (FGM) are derived using classical plate theory (CPT) and Rayleigh integral using the elemental radiator approach. Four cases, segregated on power-law index k=0,1,5,10, are studied. A novel approach is illustrated to compute sound fields of vibrating FGM plates using the physical neutral surface with an elemental radiator approach. The material properties of the FGM plate for all cases are calculated considering the power law indexes. An in-house MATLAB code is written to compute the natural frequencies, normal surface velocities, and sound radiation fields are analytically calculated using semi-analytical formulation. Ansys is used to validate the computed sound power level. The parametric effects of the power law index, modulus ratios, different constituent of FGM plates, boundary conditions, damping loss factor on the sound power level, and radiation efficiency is illustrated. This work is the benchmark approach that clearly explains how to calculate acoustic fields using a solid layered FGM model in ANSYS ACT. It shows that it is possible to asymptotically stabilize the structure by controlling the intermittent layers' stiffness. It is found that sound fields radiated by the elemental radiators approach in MATLAB, ANSYS and literatures are in good agreement. The main novelty of this research is that the FGM plate is analyzed in the low-frequency range, where the stiffness-controlled region governs the whole analysis. It is concluded that a clamped mono-ceramic FGM plate radiates a lesser sound power level and higher radiation efficiency than a mono-metallic or metal-rich FGM plate due to higher stiffness. It is found that change in damping loss factor does not affect the same constituents of FGM plates but has significant effects on the different constituents of FGM plates.

Development of Doubler Design System for Ship Plate Members Subjected to In-plane Shear and Biaxial Compressive Loads (면내 전단하중과 양축압축하중을 받는 선박 판부재의 이중판 설계시스템 개발)

  • Ham, Juh-Hyeok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.3
    • /
    • pp.242-249
    • /
    • 2017
  • A design system for doubler reinforcement of the ship plate members subjected to in-plane shear and biaxial compressive loads was developed. This design system of doubler reinforcement on ship plate members established by design supporting system and this system was based on the buckling evaluation process of ship plate members for these in-plane loads. Each design parameters were suggested by equations as the form of influence coefficients for the doubler reinforcement subjected to the various in-plane loads including shear load. Strength of doubler plate member reinforced on the plate member could be suggested by the equivalent flat plate thickness after the consideration of corelation equations in the design system of doubler reinforcement. Level of strength recovery of ship plate members for these in-plane loads according to the local reinforcement by doubler could be suggested by use of this design system in the initial repair design stage of shipyards.

Outcome Analysis of the Patients with and without Anterior Plating in Multi-Level Degenerative Cervical Diseases (다분절 퇴행성 경추질환에서의 전방 금속판 사용 유무에 따른 환자의 예후분석)

  • Kim, Sang Woo;Kim, Sung Min;Shin, Dong Ik;Cho, Yong Jun;Shim, Young Bo;Choi, Sun Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1369-1374
    • /
    • 2001
  • Objectives : The rates of pseudarthrosis for two- and three level fusion have been reported to be 17-63 and 50% without anterior cervical plating. The purpose of this study is to assess the effects of anterior cervical plating in the treatment of multilevel degenerative cervical disease such mostly the additional risks associated with hardware implants and its benefits, fusion rate and radiographic results, and clinical outcomes. Methods : Forty-seven patients who underwent operations between 1993 and 1997 were retrospectively reviewed. The technique for operation was same for both groups(Smith Robinson with autologous iliac bone graft). Group I consisted of 35 consecutive patients treated with anterior cervical decompression and fusion with anterior cervical plate fixation. Group II consisted of 12 consecutive patients treated without plate fixation. We compared clinical outcomes by Prolo score, radiographic results in the rate of fusion, cervical lordosis by Gore angle, disc height by Farfan method, and surgical complications between two groups. Results : The favorable clinical outcomes(excellent and good) by Prolo score were observed with the use of anterior cervical plate fixation(89% vs 75%). The successful fusion rate of multilevel cervical fusion was as seen with anterior cervical plate fixation(97% vs 75%). The overall graft complication rate in multilevel fusions was decreased, with anterior cervical plate fixation, and the hardware related complications were relatively minimal without serious consequences. Conclusion : Anterior cervical plate fixation in the treatment of multilevel cervical disorders is an effective stabilizing method which provides increased bony fusion rate, decreased graft complications, maintained cervical lordosis, early mobilization of the these patients without serious hardware related complications.

  • PDF

Phenomena of Liquid Jet Breakup in High Speed Gas Stream (고속유동장내 액체분열현상)

  • Park, Y.K.;Seok, J.K.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.1 no.2
    • /
    • pp.66-73
    • /
    • 1996
  • The present study investigates experimentally the characteristics of liquid jet, which is, the spray flow in the normal direction of the air stream under the flow conditions of air velocity $110\sim125m/s$. The present study adopts with the flow visualization technique using a short duration light bulb and the image processing analyse with CCD camera. Two types of injector were used: one is a flat plate type, and the other is backward facing step type, which height are 5, 8, 10mm. Dispersion of liquid jet can be represented by gray level of CCD camera. In the upstream of liquid jet, the backward facing step shows better liquid jet penetration. However, in the downstream. mean droplet size for backward facing step injector is smaller than that for flat plate injector

  • PDF

Radiation characteristics on a stiffened plate structure (보강된 평판구조물의 음향방사특성에 관한 실험적 고찰)

  • Kang, Jun-soo;Kim, Jeung-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.879-886
    • /
    • 1998
  • It is very important to understand the vibration and noise characteristics of a structure to developed quiet machines and lessen their noise. In this paper, the vibration and sound radiation characteristics of a simple and a bar-stiffened plate have been investigated using numerical and experimental techniques. In numerical process, FEM analysis has been performed for the vibration level ; the time-space squared and averaged velocity and BEM analysis for sound radiation parameters ; sound power and radiation efficiency. In experimental process, FFT signal processing method has been used. While a power from an exiciter is applied to the structure by using a point contact, sound intensity and vibration level has been measured. Based on these two data, the radiation efficiency has been calculated. Results show that the radiation efficiency for the stiffened structure increases compared to the simple plate, due to the extra edges provided by the stiffener.

A Study on Effects of Piston Pumping Phase on Vibration and Noises of Tandem Swash Plate Type Axial Piston Pump(2) (피스톤 펌핑 위상이 텐덤형 사판식 액셜 피스톤 펌프의 진동, 소음에 미치는 영향에 관한 연구(2))

  • Park, Sung-Hwan;Lee, Jin-Kul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.12
    • /
    • pp.31-39
    • /
    • 1999
  • Previous researches and experiments have already verified that the primary noise source of high pressure tandem axial thpe piston pump is fluid-borne noise from the process of oil distribution between the kidney-shaped port and valve plate. So, many researchers have improved pressure gradients and reduced sound levels by applying pre-compression and pre-decompression metering grooves to valve plate. In practice however, the sound level of th high pressure tandem axial type piston pump is still undesirable. This paper testified the effect of pumping phase of the piston on vibration and noise of th high pressure tandem axial type piston pump on the best of theoretical research in $this^(1)$. Therefore considering the pumping phase of the piston when assembling the tandem axial type piston pump, it is possible to reduce 1.5~2[dB]of sound level.

  • PDF

The effect of the flow on the absorption performance of a perforated plate system (다공판 시스템의 흡음성능에 유동이 미치는 영향)

  • 허성욱;제현수;양수영;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.879-884
    • /
    • 2003
  • This paper is to experimentally investigate the effect of the through-flow and grazing-flow on the absorption performance of a perforated plate system. The experiment is performed through the systematic change of the through-flow velocity, grazing-flow velocity, incident sound pressure level, and the geometrical parameters such as the porosity and hole diameter. From the experimental results, it is found that for the nonlinear relationship between the acoustic resistance and incident sound pressure level there is no influence of the through-flow on the absorption performance, but fur the linear relationship between them there is a strong dependence of the absorption performance on the through-flow velocity. It is also shown that the absorption performance is controllable by changing the porosity and hole-diameter in size.

  • PDF