• Title/Summary/Keyword: Lenses

Search Result 936, Processing Time 0.028 seconds

Assessment of UV Blocking Performance for Development of Converged Technologies of Vision Correcting Spectacle Lenses (시력교정용 안경렌즈의 융복합적 기술개발을 위한 UV차단 성능 평가)

  • Kim, Heung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.93-98
    • /
    • 2018
  • This study was wanted to confirm ability for UV blocking according to its material. The lenses materials were Acryl, CR-39, NK-55, and MR-8. It was grouped: Group A consisting of anti-scratch hard coated lenses and anti-refractive multi coated lenses, Group B added UV blocking coating on the group A, and Group C consisting of only UV blocking lenses. The results measured UV transmittance, On the UV-A wavelength, Group A showed the UV transmittance of 7.726%, 0.043%, 0.007%, and 0.007% respectively. Group B showed 0.038%, 0.037%, 0.007%, and 0.007%, respectively. The UV-blocking performance of CR-39 has been greatly improved. Group C has shown the best UV blocking function; only 0.005% and 0.004% of UV transmittances.(1.60 and 1.67 index of refraction respectively). For the low power of lenses and sunglasses, the CR-39 lens is the most used. Therefore, to UV blocking from the lens, new materials or UV absorbers or UV coating technology and development of Converged Technologies are required.

A Convergence Study on Wearing Contact Lenses after Corneal Refractive Surgery (각막굴절수술 후 콘택트렌즈 착용에 대한 융복합적 연구)

  • Park, Hye-Won
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.8
    • /
    • pp.117-125
    • /
    • 2018
  • Aims of this study was to investigate on the actual condition of contact lens wearing after corneal refractive surgery, base curves and diameters of lenses on sale, and to confirm movement of lens and wear patterns when wearing of lenses in the modified cornea. After surgery, 16.5% of the respondents had experience wearing contact lenses. Also, the mostly distributed contact lenses had B.C. 8.6mm and DIA.14.0mm. The corneas of 24 eye after corneal refractive surgery were flat, the lenses moved towards inferior and temporal when wearing the lens. After corneal refractive surgery, contact lens wear may feel uncomfortable may require the detailed description and sophisticated fitting due to the limited type of contact lens. It is thought that convergence will be necessary in the industry and clinical study of contact lenses.

A Comparative Study of Ophthalmic Spectacle Lenses Standards (시력보정용 안경렌즈의 규격에 관한 비교 고찰)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.397-415
    • /
    • 2004
  • This study surveyed differences among KS, ISO, JIS and ANSI ophthalmic spectacle lenses standards. These standards applied to several lenses that were in common currency and we checked over problems and improvements in KS. KS corresponded to ISO, for the most part, and ANSI, partly. But terms, definitions, progressive power lenses standards, UV transmittance and base curves clauses did not exist in KS. There was no differences between nominal data and actual data in important clauses estimation-minimum requirements on refractive power, tolerances on the size of lenses, material and surface quality. But tolerances of thickness, base curves, UV and visible transmittance values were not existing, there were differences among several ophthalmic spectacle lenses in the test of these clauses. These requirements will be needed for better and more comfortable vision.

  • PDF

Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass (칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작)

  • Oh, Seung Eun;Lee, Sun Kyu;Choi, Joong Kyu;Song, Kook Hyun;Baek, Jong Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • In this paper, for low cost infrared optical equipment, we design and fabricate an infrared optical system for an uncooled detector using PGM(Precision Glass Molding) lenses. The designed infrared optical system has a good athermalization, and the material of all of its lenses is a chalcogenide glass suitable for the PGM method. In addition, we also fabricate the same infrared optical system using SPDT(Single Point Diamond Turning) lenses in order to measure the optical performance of PGM lenses. We measure the MTF(Modulation Transfer Function) of the two infrared optical systems which use the PGM lenses and the SPDT lenses. And then we compare and analyze the images of them both. As a result, we find that they have only a very small difference in optical performance. If the use of PGM lenses increases, we expect to reduce the cost of infrared optical equipment.

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Microorganism Contamination from Wearing One-Day Disposable Contact Lenses According to Wearing Time (일일 착용 콘택트렌즈의 연속 착용에 따른 세균 오염)

  • Choi, Gang-Won;Jang, Woo-Yeong;Lee, Jong-Wook;Kim, Su-Jung
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.152-156
    • /
    • 2010
  • Disposable contact lenses, which are one type of soft contact lenses, provide convenience in use, but also cause various ocular infectious diseases. Microorganisms that cause eye diseases include Acanthamoeba, bacteria, Fungi, and so on. It is impossible to prevent microorganism contamination completely due to the use of hands as wearing contact lenses. The contamination by various microorganisms leads to infectious keratitis, but it is not well known for the exact microorganisms that affect the disease. For this reason, to identify the microorganisms, two groups that are commonly used for disinfection of lenses were divided: normal saline solution and multiple purpose solution. Using these solutions the degree of microorganism contamination was observed according to the days of 1, 3, 5, 10, and 15. Twenty students by two groups from Ophthalmic Optics department at D college in Daegu Metropolitan city participated in the experiment after their ocular health conditions were checked. During they wore one-day disposable lenses for 1, 3, 5, 10, and 15 days, bacteria were cultured in media. The results, which were Gram stained by selecting the cultured colonies, show as followings: Gram positive cocci 33%, Gram-negative cocci 2%, Gram positive bacilli 34%, and the Gram negative bacilli 31%, respectively. As for the identification of potential pathogens, VITEK system and API kit methods were used. Keratitis caused by bacteria known as Staphylococcus aureus, Pseudomonas aeruginosa were detected as a result of wearing contact lenses. This study examined the distribution of bacteria as wearing one-day disposable contact lenses and pathogenic bacteria according to the duration of wearing them. In conclusion, the importance of hygiene when using contact lenses is suggested.

Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes (역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향)

  • Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the corneal topographical changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The shape and fluorescein pattern of everted silicone hydrogel lenses were investigated. The subject wore the silicone hydrogel everted lenses overnight for 8 hours. Objective refractive error and corneal shape were evaluated at baseline, 1, 2, 3, 5, and 7 days after lens wearing and 1,2,3, and 4 days after discontinuation of lens wear. Results: The Fluorescein pattern of everted silicone hydrogel lenses was similar to the reverse geometry lenses with pressure profile. Objective refractive error(sphere power) and corneal refractive power were decreased and corneal shape had changed during the everted silicone hydrogel lenses wear and recovered during the 4 days of discontinuation. Subject experienced no discomfort associated with the everted silicone hydrogel lenses. Conclusions: It appears that everted silicone hydrogel lenses are capable of inducing significant changes in corneal topography, with overnight wear. Further study must be done to help understand these changes to develop a predictable and effective way of using soft contact lenses for corneal reshaping.

Mold Filling Analysis and Post-deformation Analysis of Injection-molded Aspheric Lenses for a Mobile Phone Camera Module (휴대폰 카메라용 비구면렌즈의 성형해석 및 후변형해석)

  • Park, Keun;Eom, Hyeju;Ahn, Jong-Ho
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.12-17
    • /
    • 2012
  • In order to produce high-quality optical components, aspheric lenses have been widely applied in recent years. An aspheric lens consists of aspheric surfaces instead of spherical ones, which causes difficulty in the design process as well as the manufacturing procedure. Although injection molding is widely used to fabricate optical lenses owing to its high productivity, there remains lots of difficulty to determine appropriate mold design factors and injection molding parameters. In the injection molding fields, computer simulation has been effectively applied to analyze processes based on the shell analysis so far. Considering the geometry of optical lenses, a full-3d simulation based on solid elements has been reported as a reliable approach. The present work covers three-dimensional injection molding simulation and relevant deformation analysis of an injection molded plastic lens based on 3d solid elements. Numerical analyses have been applied to the injection molding processes of three aspheric lenses for an image sensing module of a mobile phone. The reliability of the proposed approach has been verified in comparison with the experimental results.

  • PDF