• Title/Summary/Keyword: Lens refractive power

Search Result 65, Processing Time 0.019 seconds

Changes of the Plastic Lens Properties Caused by Etching of the Coating Films (코팅막 식각으로 인한 플라스틱 렌즈의 특성 변화)

  • Moon, Byeong-Yeon;Hwang, Ki Ju;Lee, Yoon Jeong;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: We investigated the changes of plastic lens after etching of coating films by comparing uncoated lens. Methods: CR-39, middle index and high index lenses of 0 (zero) diopter were etched at $80^{\circ}C$ and room temperature using a coating remover, and then changes of refractive power, transmittance and surface morphology were investigated. Results: There were no differences in refractive power and transmittance between uncoated and etched lenses. The etching rate was similar in both CR-39 and middle index lens, but in the case of high index lens, it was slower and less steady than the others. From the SEM observation of lens surface, etching damage was found out on the surface of etched lens. It was shown the least damage in middle index lens but the most damage in high index lens. Conclusions: If the etching of coating films is demanded on condition that the surface of ophthalmic lenses are not damaged, a using of most adequate coating remover based on lens material should be considered, and a caution for proper etching conditions is required.

A Comparative Study on Ophthalmic Lenses Standards (시력 보정용 안경렌즈의 규격 비교 연구)

  • Kwak, Ho-Won;Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.221-228
    • /
    • 2005
  • In order to analyze the difference of lenses production, we measured the refractive power and the thickness of their optical centers using ophthalmic lenses which were distributed at home country and abroad. The home products were manufactured to be next to foreign goods, but there were several cases to exceed acceptable limits and we need to reduce the deviation from measuring values in the same lenses. To get a beat on advanced countries, rearing technical expert, hard quality test and process control and standardization of lenses are essential to home lens industrials.

  • PDF

Study of Ocular Components in Determining the Refractive State of the Eye (굴절이상을 결정하는 안광학 요소에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between ocular components and refractive error for human eye. Ocular components were measured by keratometry, phakometry, and ultrasonography. Refractive error was measured by subjective refraction on 38 subjects aged from 17 to 30. The results were as follows; 1) Refractive error and axial length, vitreous chamber depth, axial length/corneal radius were highly correlated that the correlation coefficients were 0.95, 0.96, 0.95, respectively. 2) Refractive error and corneal radius, corneal power, lens thickness were correlated with the correlation coefficients for 0.60, 0.66, 0.67 respectively. 3) There were no significant correlation between refractive error and corneal thickness.

  • PDF

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.

Improvement of Color Temperature Uniformity of Integrated Optic Lens Type LED Packaged using Compression Molding Method (가압성형 방식을 사용한 렌즈 일체형 LED 패키지의 색온도 균일성 향상에 관한 연구)

  • Kim, Wan-Ho;Kang, Young-Rae;Jang, Min-Suk;Joo, Jae-Young;Song, Sang-Bin;Kim, Jae-Pil;Yeo, In-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • Optical characteristics including the view angle and color temperature uniformity of LED packages with an integrated lens fabricated by compression molding method are investigated according to lens shape, lens materials, and phosphor coating methods. Four types of lens shape are designed and their optical output power dependence on the refractive index of silicone encapsulant are evaluated. Also, spatial color temperature uniformities of packages fabricated with different phosphor coating methods-direct coating on a chip vs. uniformly mixed with silicone encapsulant- are compared at various view angles. As the result, it is found that phosphor coating method is more effective on color temperature uniformity than lens shape. The maximum color temperature difference of a package with direct coating of phosphor on a chip is 1,340K according to the view angle at the color temperature of 5,000K, and that of a package with uniformly mixed phosphor is 250K, which indicates 1,090K improvement of color uniformity for the latter case.

Study on the Labeling Items and Reliability of Spectacle Lens (안경렌즈의 표시사항 및 신뢰성에 관한 연구)

  • Ye, Ki-Hun;Kim, Tae-Hun;Kwon, Young-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.323-327
    • /
    • 2006
  • For this study we research investigated the current situation of packing on the labeling items of domestic spectacle lens and reliability of spectacle lens. We use sample which is three hundred and ninety six spectacle lenses of eight company total. Refractive index of each sample in experiment is 1.55~1.56, 1.60~1.61 and 1.67. The percentage of labeling of A company and B company indicated the percentage of labeling of 80%, but The percentage of labeling of two companies indicated only 52.1% and 56.9% seperately. The most companies indicated comparatively a low marking ratio about packing on the labeling items. The results of difference the value of power which is recorded with the value of power which is measurement showed only small value.

  • PDF

Effects of Stray Light in Blue-light Blocking Lens on the Quality of Image (청색광 차단렌즈에서 미광이 상의 질에 미치는 영향)

  • Yuk, Ju Sung;Yang, Seok-Jun;Kim, Yong Gwon;Choi, Eun Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.612-618
    • /
    • 2016
  • The aim of this study is to investigate the effects of stray light originating from the blue-light blocking lens on the quality of the image. After designing the ideal spectacle lens, anti-reflection spectacle lens without internal reflection, anti-reflection spectacle lens with internal reflection, and blue-light blocking lens with internal reflection, the light intensity distribution and stray light distribution were derived. The designed spectacle lenses are meniscus lenses with a refractive power of 0.00 D, refractive index of 1.56, and a radius of 155.15 mm. The peaks of reflectance of the 4 types of blue-light blocking lenses are in the range between 430 nm and 440 nm, and their reflectances are 5%, 10%, 15%, and 20%, respectively. According to the analysis results, as the reflectance of the blue-light blocking lens increases, the light intensity in the center of the lens decreases and the intensity of the stray light in the center-periphery and periphery of the lens increases. This trend appeared to intensify with increasing reflectance of the blue-light blocking lenses. Because the increase in the reflectance of the blue-light blocking lens degrades the quality of the image by increasing the intensity of the stray light in the center-periphery and periphery of the lens, its reflectance needs to be adjusted by varying the blue-light blocking ratio and the luminous transmittance, in order to diminish the level of visual discomfort.

The Variable Process of Visual Acuity for Artificial Myopia (인위적인 근시에서 시력의 회복과정)

  • Choi, Woon Sang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.55-60
    • /
    • 1997
  • Numerically compares a calculation about a variable process of visual acuity for a artificial myopia with previously the tested result. The calculation is used to the value of Gullstrand's theoretical eyes and a method of geometrical optics. The theoretical eye simplified a entrance pupil and retina. Optical lens and eye changed a equivalent lens. Refractive power of a equivalent lens is converted to focal length within theoretical eyes, and this was calculated about relation of a blur circle on the retina and visual acuity.

  • PDF

Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes (역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향)

  • Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the corneal topographical changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The shape and fluorescein pattern of everted silicone hydrogel lenses were investigated. The subject wore the silicone hydrogel everted lenses overnight for 8 hours. Objective refractive error and corneal shape were evaluated at baseline, 1, 2, 3, 5, and 7 days after lens wearing and 1,2,3, and 4 days after discontinuation of lens wear. Results: The Fluorescein pattern of everted silicone hydrogel lenses was similar to the reverse geometry lenses with pressure profile. Objective refractive error(sphere power) and corneal refractive power were decreased and corneal shape had changed during the everted silicone hydrogel lenses wear and recovered during the 4 days of discontinuation. Subject experienced no discomfort associated with the everted silicone hydrogel lenses. Conclusions: It appears that everted silicone hydrogel lenses are capable of inducing significant changes in corneal topography, with overnight wear. Further study must be done to help understand these changes to develop a predictable and effective way of using soft contact lenses for corneal reshaping.

A Study on the Change of Corneal Refractive Power before and after Wearing RGP Contact Lenses by Flat Fitting and Alingment Fitting with Diagnostic Method (RGP 콘택트렌즈의 진단적 피팅법에 의한 플랫한 피팅과 얼라인먼트 피팅 착용 전·후 각막 굴절력의 변화에 관한 연구)

  • Lee, Dae-Won;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.