• 제목/요약/키워드: Lens power

검색결과 332건 처리시간 0.022초

배율 타원 근사법을 실린더 렌즈의 굴절력 측정 (Measurement of the Power of a Cylindrical Lens with the Magnification Ellipse Fitting Method)

  • 고우석;예상헌;곽윤근;김수현
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.43-48
    • /
    • 2008
  • This paper proposes a new method for measuring the power of spherical and cylindrical lens with 6 points light source, which is composed of a LED and six holes, and magnification ellipse fitting algorithm. Each measured diagonal length of 6 points light source is determined by the target lens power. After finding the center position of each light point with threshold method, 3 axis-diagonal lengths were calculated. The long axis and short axis power of cylindrical lens can be calculated by using magnification ellipse fitting algorithm with the magnification relationships between the initial diagonal lengths and the measured diagonal lengths changed by lens power.

(-) 구면 렌즈 면의 반사상에 의한 굴절력 측정 (Measurement of Refractive Power by Reflective image on the Negative Spherical Lens)

  • 최운상;김대현
    • 한국안광학회지
    • /
    • 제9권2호
    • /
    • pp.417-421
    • /
    • 2004
  • 안경렌즈 면 위에 반사되는 상을 관찰하연 한 물체에 대해 두 개의 상이 나타나 있다. 이것은 렌즈 전면에서 반사되는 상과 렌즈 후면에서 반사되는 상이다. 이 상들은 렌즈 전, 후면의 굴절력에 의해 렌즈 면에서 반사되는 상이며, 렌즈 전체의 굴절력은 렌즈 전, 후면의 굴절력을 이용하면 얻을 수가 있다. 그러므로 렌즈 면 위에서 나타나는 상 크기 측정은 렌즈의 굴절력을 측정하는 기기의 도움 없이 렌즈의 굴절력을 측정하는 방법이 될 수 있다. 렌즈 면 위에서 측정된 두 개 반사상의 비와 굴절력을 측정하여 계산한 값과 비교하였다.

  • PDF

자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가 (Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter)

  • 이형균;김소라;박미정
    • 한국안광학회지
    • /
    • 제20권4호
    • /
    • pp.501-509
    • /
    • 2015
  • 목적: 자동포롭터의 표기 도수와 구면굴절력 및 원주굴절력 실측값을 비교하여 굴절력의 신뢰도를 평가하였다. 방법: 자동포롭터의 마이너스 구면렌즈 및 원주렌즈의 굴절력을 수동렌즈미터로 측정하여 표기도수와의 정확도를 비교하였으며 두 렌즈가 중첩되었을 때의 합성굴절력과 등가구면굴절력을 시험렌즈와 비교 평가하였다. 결과: 포롭터에 내장되어 있는 구면렌즈의 구면굴절력은 70.6%가 표기도수와 0.125 D 이상의 오차가 발생하였으며, 굴절력이 높아질수록 오차값도 증가하였다. 원주렌즈의 단일 원주굴절력은 표기도수와 거의 일치하였다. 포롭터에서 구면렌즈와 원주렌즈가 중첩되었을 때의 합성 구면굴절력은 단일렌즈 구면굴절력과 동일하여 중첩에 의한 구면굴절력의 변화가 없음을 알 수 있었다. 그러나 구면렌즈와 원주렌즈가 중첩되었을 때의 원주굴절력은 표기도수와 큰 차이가 있어 중첩에 의해 영향을 받는다는 것을 알 수 있었다. 포롭터를 이용하여 실측된 등가구면굴절력은 표기도수 및 시험테를 이용한 등가구면굴절력에 비해 낮았으며 고도수일수록 더 낮았다. 결론: 고도의 근시안 또는 근시성 난시 안에서 자동포롭터를 사용하여 시력검사를 하는 경우 표기도수와 차이가 발생하며 과교정이 될 것으로 보여 이에대한 개선이 필요할 것으로 보인다.

A preliminary evaluation of the implementation of a radiation protection program for the lens of the eye in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Cho, Moonhyung;Jung, Yoonhee;Son, Jung Kwon;Jang, Han;Kim, Hee Geun
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3035-3043
    • /
    • 2021
  • Epidemiological research has revealed that radiation exposure can cause cataracts. The Korean nuclear regulatory body has proposed the reduction of the occupational dose limit for the lens of the eye from 150 mSv/y to 100 mSv/5y, with an additional limitation of not exceeding 50 mSv/y for a specific year, taking into account the recommendations of the International Commission on Radiological Protection, and the International Atomic Energy Agency. This means that radiation workers should receive the same level of radiation safety for the lens of the eye as for whole-body protection. Korean nuclear power plants (NPPs) are conducting research to establish the radiation protection program for the lens of the eye. In terms of the preliminary results of the implementation of the radiation protection program for the lens of the eye dedicated to Korean NPPs, this review article summarizes the current state of understanding of the regulations, technical guidance, eye lens dosimeters, and radiation field conditions resulting in lens dose.

홀더종류에 따른 소프트 콘택트렌즈의 정점굴절력 측정의 정확도 분석 (Analysis of Vertex Refractive Power Accuracy of Soft Contact Lens with Holder Type)

  • 이민제;성아영
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.105-115
    • /
    • 2015
  • 목적: 본 연구는 안경렌즈홀더와 콘택트렌즈홀더를 사용하여 다양한 디옵터와 함수율을 가진 소프트 콘택트렌즈의 굴절력을 측정하고 정확도를 평가하여 그 차이를 비교하였다. 방법: 실험에 사용한 소프트 콘택트렌즈의 함수율은 각각 38%, 43% 및 58%이었으며, 굴절력에 따라 -3.000 D, -7.000 D 및 -10.000 D로 분류하여 각각 실험하였다. 또한 망원경식 렌즈미터를 사용하여 안경렌즈홀더 및 콘택트렌즈홀더로 각각의 정점굴절력을 측정하여 정확도를 분석하였다. 결과: 안경렌즈홀더를 사용한 경우 -3.0000 D는 -3.3273 D로 측정되었으며, -7.0000 D는 -7.1306 D, -10.0000 D는 -10.2944D로 각각 측정되었다. 또한 콘택트렌즈홀더를 사용한 경우 -3.0000 D는 -3.1060 D로 측정되었으며, -7.0000 D는 -7.0028 D, -10.0000 D는 -10.2611 D로 각각 측정되었다. 모든 종류의 콘택트렌즈에서 콘택트렌즈홀더를 사용한 방법이 안경렌즈홀더를 사용한 방법보다 더 정확한 측정값을 나타내었다. 결론: 위 결과로 볼 때, 망원경식 렌즈미터를 사용한 소프트 콘택트렌즈의 굴절력 측정에 있어 콘택트렌즈홀더를 사용한 방법이 안경렌즈홀더를 사용한 방법보다 더 높은 정확도를 가진 것으로 판단된다.

Graphical Selection of Optical Materials Using an Expanded Athermal Glass Map and Considering the Housing Material for an Athermal and Achromatic Design

  • Lim, Tae-Yeon;Kim, Yeong-Sik;Park, Sung-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제19권5호
    • /
    • pp.531-536
    • /
    • 2015
  • This paper presents a new graphical method for selecting a pair of optical glass and housing materials to simultaneously achromatize and athermalize a multilens system composed of many elements. To take into account the lens spacing and housing, we quantify the lens power, chromatic power, and thermal power by weighting the ratio of the paraxial ray height at each lens to them. In addition, we introduce the equivalent single lens and the expanded athermal glass map including a housing material. Even though a lens system is composed of many elements, we can simply identify a pair of glass and housing materials that satisfies the athermal and achromatic conditions. Applying this method to design a black box camera lens equipped with a 1/4-inch image sensor having a pixel width of $2{\mu}m$, the chromatic and thermal defocusings are reduced to less than the depth of focus, over the specified ranges in temperature and frequency.

Relationship between Surface Sag Error and Optical Power of Progressive Addition Lens

  • Liu, Zhiying;Li, Dan
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.538-543
    • /
    • 2017
  • Progressive addition lenses (PAL) have very wide application in the modern glasses market. The unique progressive surface can make a lens have progressive refractive power, which can meet the human eye's different needs for distance-vision and near-vision. According to the national glasses fabrication standard, the difference between actual optical power after fabrication and nominal design value should be less than 0.1D over the lens effective area. The optical power distribution of PAL is determined directly by the surface. Consequently, the surface processing accuracy requirement is proposed. Beginning from the surface expressions of progressive addition lenses, the relationship equations between the surface sag and optical power distribution are derived. They are demonstrated through tolerance analysis and test of an example progressive addition lens with addition of 2.09D (5.46D-7.55D). The example addition surface is fabricated under given accuracy by a single-point diamond ultra-precision machine. The optical power of the PAL example is tested with a focal-meter after fabrication. The optical power addition difference between test result and design nominal value is 0.09D, which is less than 0.1D. The derived relationship between the surface error and optical power is verified from the PAL example simulation and test result. It can provide theoretical tolerance analysis proof for the PAL surface fabricating process.

중첩된 시험렌즈의 합성굴절력에 대한 신뢰도 평가 (The Evaluation of Reliability for the Combined Refractive Power of Overlapping Trial Lenses)

  • 이형균;김소라;박미정
    • 한국안광학회지
    • /
    • 제20권3호
    • /
    • pp.263-276
    • /
    • 2015
  • 목적: 구면렌즈와 원주렌즈를 시험테에 중첩하였을 때 합성굴절력의 신뢰도를 알아보고자 하였다. 방법: 마이너스 구면 시험렌즈와 원주 시험렌즈의 굴절력, 중심두께 및 주변부두께를 측정하였으며 구면 시험렌즈와 원주 시험렌즈를 장입순서를 바꿔가며 시험테에 중첩되었을 때의 굴절력을 자동렌즈미터로 측정하여 합성굴절력 계산값과 비교 평가하였다. 결과: 시험렌즈의 중심부와 주변부의 두께증감이 도수의 증감과 상관성을 보이지 않았으며 79개 시험렌즈 중 3개의 시험렌즈에서 국제기준규격(ISO-9801)에서 벗어난 굴절력이 측정되었다. 정점간거리를 보정하는 굴스트랜드 공식 굴절력값이 얇은 렌즈 공식 굴절력값보다 실측값과의 오차가 적었으나, 여전히 실측값과는 통계적으로 유의한 차이가 있었다. 굴절력의 크기는 원주렌즈와 구면렌즈의 위치와 상관없이 평균적으로 얇은 렌즈 공식 굴절력값 > 실측 굴절력값 > 굴스트랜드 공식 굴절력값 순으로 나타났다. 구면렌즈가 안쪽, 원주렌즈가 바깥쪽에 장입되었을 경우에는 굴스트랜드 공식에 대입하였을 때 원주굴절력만 오차가 발생하지만 원주렌즈가 안쪽, 구면렌즈가 바깥쪽에 장입되었을 때는 구면굴절력과 원주굴절력 모두에서 오차가 나타났다. 실측값의 등가구면굴절력을 비교하였을 때 구면렌즈가 시험테의 안쪽, 원주렌즈가 시험테의 바깥쪽에 장입된 경우가 정확도가 더 높았으며 과교정의 우려가 작았다. 결론: 본 연구 결과 시험렌즈테에 렌즈를 중첩하였을 때의 합성굴절력은 정점간거리 외에도 중첩되는 렌즈의 두께와 광학중심 등의 영향을 받으며 구면렌즈와 원주렌즈의 중첩 순서에 따라 굴절력에 차이가 있으므로 이에 대한 기준의 정립이 필요함을 제안한다.

오프셋용 국산 아트지의 인쇄적성에 관한 연구 (A Study on the Printability of Domestic Art Papers for Offset Printing)

  • 원경희
    • 한국인쇄학회지
    • /
    • 제14권1호
    • /
    • pp.55-74
    • /
    • 1996
  • In the today, regarded as a science on photography, the role of the lens and sensitized is important. In this research, we manufactured a hand-made lens which is based on the general purpose lens, and made a diapgragm. We measured the quantity of light and resolving power, and take pictures with it. The purpose of this research is to figure out the characteristics of our hand-made lens and maximize its usefulness. The result showed that (1) quantity of light and resolving power through hand-made lens are distributed constant. (2)Our lens had the characteristics of a soft lens and (3)it had much chromatic abberation. Therefore, we found that the hand-made lens is th acquire visual image such as the effects of a specialized lens.

  • PDF

CD-ROM 드라이브의 대물렌즈 입자오염이 Laser Diode의 Power와 Photo Diode의 RF Signal에 미치는 영향 (Effect of Particle Contamination on Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RF Signal)

  • 배양일;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1429-1434
    • /
    • 2003
  • A number of dust particles are intruded into ODD(Optical disk drive) due to the flow caused by disk rotation and are adhered to a lens or disk surface. The space between the disk and the lens is being reduced. Someone indicates the problems of this drive that are relatively small data storing capacity and slow access time. In recent, the problems of this optical disk drive mentioned above are being solved by adding the speed of the disk's revolution, making the actuator high-speed or light, and making the beam spot size smaller than making the space narrow between disk and lens. These particle contamination affects seriously RF Signal, readout signal in an ODD. Especially, the affected parts by a particle contamination in an ODD's readout signal are objective lens and media.

  • PDF