• Title/Summary/Keyword: Lens optimization

Search Result 124, Processing Time 0.05 seconds

3-axis Moving Magnet Type Actuator (가동 자석형 3 축 구동 엑츄에이터)

  • Hur, Young-Jun;Song, Myeong-Gyu;Park, No-Cheol;Yoo, Jeong-Hoon;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1033-1036
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to equip 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added tilting mechanism to 2-axis moving magnet actuator which is designed in previous research. Addition of the tilting mechanism cuts down the focusing sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

Maximizing the Workspace of Optical Tweezers

  • Hwang, Sun-Uk;Lee, Yong-Gu
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.162-172
    • /
    • 2007
  • Scanning Laser Optical Tweezers(SLOT) is an optical instrument frequently employed on a microscope with laser being delivered through its various ports. In most SLOT systems, a mechanical tilt stage with a mirror on top is used to dynamically move the laser focal point in two-dimensions. The focal point acts as a tweezing spot, trapping nearby microscopic objects. By adding a mechanical translational stage with a lens, SLOT can be expanded to work in three-dimensions. When two mechanical stages operate together, the focal point can address a closed three-dimensional volume that we call a workspace. It would be advantageous to have a large workspace since it means one can trap and work on multiple objects without interruptions, such as translating the microscope stage. However, previous studies have paid less consideration of the volumetric size of the workspace. In this paper, we propose a new method for designing a SLOT such that its workspace is maximized through optimization. The proposed method utilizes a matrix based ray tracing method and genetic algorithm(GA). To demonstrate the performance of the proposed method, experimental results are shown.

Theoretical Limits Analysis of Indoor Positioning System Using Visible Light and Image Sensor

  • Zhao, Xiang;Lin, Jiming
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.560-567
    • /
    • 2016
  • To solve the problem of parameter optimization in image sensor-based visible light positioning systems, theoretical limits for both the location and the azimuth angle of the image sensor receiver (ISR) are calculated. In the case of a typical indoor scenario, maximum likelihood estimations for both the location and the azimuth angle of the ISR are first deduced. The Cramer-Rao Lower Bound (CRLB) is then derived, under the condition that the observation values of the image points are affected by white Gaussian noise. For typical parameters of LEDs and image sensors, simulation results show that accurate estimates for both the location and azimuth angle can be achieved, with positioning errors usually on the order of centimeters and azimuth angle errors being less than $1^{\circ}$. The estimation accuracy depends on the focal length of the lens and on the pixel size and frame rate of the ISR, as well as on the number of transmitters used.

Optical Simulation Study on the Effect of Diffusing Substrate and Pillow Lenses on the Outcoupling Efficiency of Organic Light Emitting Diodes

  • Jeong, Su Seong;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.269-274
    • /
    • 2013
  • The effect of diffusing substrate and pillow lenses on the outcoupling efficiency of organic light-emitting diodes (OLEDs) was studied by optical simulation based on the point-dipole model. The diffusing substrate included Mie scatterers by which the condition of total internal reflection could be broken. The finite-difference time-domain method was used to obtain the intensity distribution on the transparent electrode of an OLED, which was used as a light source to carry out a ray-tracing simulation of the OLED and the diffusing substrate. It was found that the outcoupling efficiency of the OLED was sensitive to the thickness of organic layers and could be increased by 21.0% by adopting a diffusing substrate in which Mie scatterers whose radius was $2.0{\mu}m$ were included at the density of $10^7mm^{-3}$ and by 65.5% by forming one pillow lens with the radius of 2 mm on the front surface of the glass substrate. This study revealed that the outcoupling efficiency could be improved by adopting diffusing substrate and pillow lenses along with the optimization of the thickness of each layer in the OLED.

Optimum parameters of 3D integral imaging system (3차원 집적 영상 시스템의 최적 파라미터)

  • Cho, Myungjin;Lee, Byonggook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.1019-1022
    • /
    • 2012
  • Integral imaging is a promising technology for 3D imaging and display. Many parameters affect the performance of 3D integral imaging systems. Enhanced system performance is acquired by optimization of these system parameters with respect to defined performance metrics. In this paper, we present an approach to optimize the performance of 3D integral imaging system in terms of performance metrics under fixed resource constraints. In this analysis, system parameters such as lens numerical aperture, pitch between image sensors, the number of image sensors, the pixel size, and the number of pixels are determined to optimize performance metrics. Wave optics is utilized to describe the imaging process.

  • PDF

Development of 3-axis Moving Magnet Type Actuator (가동 자석형 3 축 구동 엑츄에이터 개발)

  • Song, Myeong-Gyu;Hur, Young-Jun;Park, No-Cheol;Yoo, Jeong-Hoon;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.4
    • /
    • pp.191-195
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to be equipped with 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added a tilt mechanism to the 2-axis moving magnet actuator which is designed in previous research. Addition of the tilt mechanism cuts down the focus sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

Evaluation of exposure to ionizing radiation of medical staff performing procedures with glucose labeled with radioactive fluorine - 18F-FDG

  • Michal Biegala;Marcin Brodecki;Teresa Jakubowska;Joanna Domienik-Andrzejewska
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.335-339
    • /
    • 2024
  • Employees of nuclear medicine facilities performing medical procedures with the use of open radioactive sources require continuous detailed control of exposure to ionizing radiation. Thermoluminescent (TL) detectors placed in dosimeters: for the whole body, for lenses, ring and wrist dosimeters were used to assess exposure. The highest whole-body exposure of (1.70 ± 1.09) µSv/GBq was recorded in nurses administering radiopharmaceutical to patients. The highest exposure to lenses and fingers was recorded for employees of the quality control zone and it was (8.08 ± 2.84) µSv/GBq and a maximum of (1261.46 ± 338.93) µSv/GBq, respectively. Workers in the production zone received the highest doses on their hands, i.e. (175.67 ± 13.25) µSv/GBq. The measurements performed showed that the analyzed workers may be classified as exposure category A. Wrist dosimeters are not recommended for use in isotope laboratories due to underestimation of ionizing radiation doses. Appropriately selected shields, which significantly reduce the dose received by employees, must be used in isotope laboratories. Periodic measurements confirmed that the appropriate optimization of exposure reduces the radiation doses received by employees.

Double-Gauss Optical System Design with Fixed Magnification and Image Surface Independent of Object Distance (물체거리가 변하여도 배율과 상면이 고정되는 이중 가우스 광학계의 설계)

  • Ryu, Jae Myung;Ryu, Chang Ho;Kim, Kang Min;Kim, Byoung Young;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • A change in object distance would generally change the magnification of an optical system. In this paper, we have proposed and designed a double-Gauss optical system with a fixed magnification and image surface regardless of any change in object distance, according to moving the lens groups a little bit to the front and rear of the stop, independently parallel to the direction of the optical axis. By maintaining a constant size of image formation in spite of various object-distance changes in a projection system such as a head-up display (HUD) or head-mounted display (HMD), we can prevent the field of view from changing while focusing in an HUD or HMD. Also, to check precisely the state of the wiring that connects semiconductor chips and IC circuit boards, we can keep the magnification of the optical system constant, even when the object distance changes due to vertical movement along the optical axis of a testing device. Additionally, if we use this double-Gauss optical system as a vision system in the testing process of lots of electronic boards in a manufacturing system, since we can systematically eliminate additional image processing for visual enhancement of image quality, we can dramatically reduce the testing time for a fast test process. Also, the Gaussian bracket method was used to find the moving distance of each group, to achieve the desired specifications and fix magnification and image surface simultaneously. After the initial design, the optimization of the optical system was performed using the Synopsys optical design software.

A Study on the Optimal Molding Conditions for Aspheric Glass Lenses in Progressive GMP (순차이송형 유리렌즈 성형공정에서 비구면 유리렌즈의 최적 성형조건 연구)

  • Jung, Tae-Sung;Park, Kyu-Sup;Yoon, Gil-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1051-1057
    • /
    • 2011
  • By the recently developed GMP(Glass Molding Press) process, aspheric glass lenses are widely used in many optical applications such as digital cameras, optical data storages and electrical devices etc. The GMP process can economically produce complex shaped glass lenses with high precision and good repeatability. This study deals the optimization of molding conditions for aspheric glass lenses in progressive GMP process through Design Of Experiment(Taguchi method). Tree main factors for molding conditions were selected based on pressure, temperature and cooling time at 1st cooling stage. From the analysis of experiments which were preformed with 3-cavity glass mold, it was revealed that the cooling time was the most sensitive parameter for form accuracy(PV) in progressive GMP process.

Polymer Microlens Fabrication (폴리머 마이크로렌즈 제작)

  • Ryoo, Kunkul;Kim, Younggeun;Jeon, Kwangseok
    • Clean Technology
    • /
    • v.11 no.4
    • /
    • pp.205-211
    • /
    • 2005
  • There have been many technologies and materials proposed for realizing microlens array, and plastic injection is recognized as the most promising one because of several merits such as optical properties, impact resistance, formability, lightening and environmental adaptability. Since PR reflow for injection template fabrication enables the lens shape control easier, and the sample technology more effective for mass production, it lowers the cost, enhances integration, and reduces process steps, which leads to be environmentally benign. However injection of polymers may face the difficulty of formability depending on their properties. In order to overcome the difficulty, fast heating/cooling technology was introduced in this study, and microlenses were fabricated and evaluated. template obtained by PR reflow method was heated and cooled fast during injection to fabricate microlens array. PC and PMMA polymer materials were compared, and it was realized that PMMA showed much better formability due to its lower melting temperature. Injection parameters of pressures and velocities were driven out for injection optimization.

  • PDF