• 제목/요약/키워드: Lens of the Eye

검색결과 361건 처리시간 0.023초

사진측량 기법을 사용한 어안렌즈 왜곡보정에 관한 연구 (A Distortion Correction Method for the Fish-Eye Lens using Photogrammetric Techniques)

  • 강진아;박재민;김병국
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2007년도 춘계학술발표회 논문집
    • /
    • pp.161-164
    • /
    • 2007
  • The paper studies in the wide-angle lens and distortion tendency and employs the correction techniques suitable to the fish-eye lens using the existing photographic survey methods. After carrying out the calibration of the the fish-eye lens, we calculated the correction parameters, and then developed the method that convert the original image-point to new image-point correcting distortion. The objectives of suggested calibration method in this paper are to calibrate the image of the the fish-eye lens used in the computer-vision and the control-instrumentation field widely. The proposed technique expects to improve the accuracy of the image of the fish-eye lens in the indoor tracking and monitoring field. Also the referenced cross point auto-extraction program is embodied for improving efficiency of the lens correction techniques. Consequently, this calibration method would be applied to the automated distorting correction method on not only the fish-eye lens also general lens.

  • PDF

70 mm Eye Relief를 갖는 릴레이 렌즈 방식 스코프 개발 (Development on a Relay Lens Type Scope with 70 mm Eye Relief)

  • 박승환;이동희
    • 한국안광학회지
    • /
    • 제14권3호
    • /
    • pp.29-35
    • /
    • 2009
  • 목적: 70 mm eye relief를 갖는 릴레이 렌즈 방식 스코프 개발. 방법: Sigma 2000 광학 설계 프로그램을 사용하여 릴레이 렌즈를 갖는 대물부와 접안부를 각각 설계하고 통합하여 70 mm eye relief를 갖는 릴레이 렌즈 방식의 스코프를 개발하였다. 결과: 릴레이 렌즈를 갖는 대물부와 접안부를 각각 설계하고 통합하는 방법으로 설계 제작되어진 70 mm eye relief를 갖는 릴레이 렌즈 방식의 스코프는 배율이 4.0배, 첫 번째 렌즈에서 마지막 렌즈까지의 거리가 약 105 mm, 경통구경 18 mm, 유효구경 13 mm를 갖는다. 또한 분해선폭은 30% MTF 값 기준으로 275 cycles/rad인 특성을 보여준다. 결론: 275 cycles/rad 에서 MTF 30% 이상인 성능을 가지며, 첫 번째 렌즈에서 마지막 렌즈까지의 거리 약 105 mm, eye relief 70 mm를 갖는 4.0의 배율을 갖는 릴레이방식의 스코프를 설계 제작하였다.

  • PDF

수정체 방사선 방호에 관한 규제기준 및 기술기준 검토 (Review on Regulatory and Technical Standards of Radiation Protection for Lens of the Eye)

  • 김시영;황석주;김재성;손중권
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2024
  • The International Commission on Radiological Protection (ICRP) lowered the annual equivalent dose limit of lens of the eye for radiation workers from 150 to 20 mSv in April 2011. This trend of lowering the equivalent dose limit for radiation workers has been observed worldwide, including international organizations such as the International Atomic Energy Agency (IAEA), International Organization for Standardization (ISO) and the European Commission (EC). In 2016, the Nuclear Safety and Security Commission of South Korea published research results that included a proposal for lowering the equivalent dose limit of lens of the eye for radiation workers in line with the ICRP recommendation. However, as of now, South Korea's Nuclear Safety Act and related regulations still specify an annual equivalent dose limit of lens of the eye as 150 mSv for radiation workers. The IAEA and ISO have issued guidelines regarding radiation protection for lens of the eye and recommended a dose level for the lens of the eye at 5 or 6 mSv per year for periodic monitoring of the equivalent dose for the lens of the eye.

A preliminary evaluation of the implementation of a radiation protection program for the lens of the eye in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Cho, Moonhyung;Jung, Yoonhee;Son, Jung Kwon;Jang, Han;Kim, Hee Geun
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3035-3043
    • /
    • 2021
  • Epidemiological research has revealed that radiation exposure can cause cataracts. The Korean nuclear regulatory body has proposed the reduction of the occupational dose limit for the lens of the eye from 150 mSv/y to 100 mSv/5y, with an additional limitation of not exceeding 50 mSv/y for a specific year, taking into account the recommendations of the International Commission on Radiological Protection, and the International Atomic Energy Agency. This means that radiation workers should receive the same level of radiation safety for the lens of the eye as for whole-body protection. Korean nuclear power plants (NPPs) are conducting research to establish the radiation protection program for the lens of the eye. In terms of the preliminary results of the implementation of the radiation protection program for the lens of the eye dedicated to Korean NPPs, this review article summarizes the current state of understanding of the regulations, technical guidance, eye lens dosimeters, and radiation field conditions resulting in lens dose.

Occurrence of eye abnormality in cultured red seabream (Pagrus major) and induced hybrid, red seabream Pagrus major(♀) ${\times}$ black seabream Acanthopagrus schlegeli(♂)

  • Iraida, Germogenovna Syasina;Park, In _Seok
    • 한국어병학회지
    • /
    • 제16권2호
    • /
    • pp.75-80
    • /
    • 2003
  • Red scabream, Pagrus major , is a valuable aquaculture species in Korea , but spontaneous eye abnormality occurred in cultured individuals . The incidence of eye abnormality was 4% in the group of cultured red scebream. The abnormality was characterized by unilateral and bilateral exophthalmos, opacity and lens pathology. Lense prolapse was found in two cases. Lenses in diseased fishes was considerably small in diameter and eyes were deformed as a whole. In the group of induced hybrid red scabream Pagrus major (♀) x black seabrearn Acanthopagrus schlegeli (♂), the incidence of eye abnormality wa~ the same 4%, but only opacity was registered. Opacity was also found in two of sixteen examined Wild-caught red seabrcam. Histopathological changes of lenses in cultured red seabreem included vecuolated cytoplasm of lens fibers, necrosis of fibers in central part of lens, folding and increase in thickness of lens capsule, and epithelial proliferation beneath the anterior lens capsule. In affected eyes no parasites or gas bubbles were found.

유발된 부동시의 교정에 따른 입체시 변화 (Changes of Stereoacuity with Correction in Induced Anisometropia)

  • 최진영;김재민;김현정
    • 한국안광학회지
    • /
    • 제13권4호
    • /
    • pp.121-126
    • /
    • 2008
  • 목적: 단안 과교정 및 저교정으로 유발된 부동시에서 정상적인 양안시기능을 유지하기 위해 필요한 최소한의 교정도수를 알아보고자 하였다. 방법: 안질환의 병력이 없는 20대의 성인 남녀를 대상으로 우위안 및 비우위안에 각각 과교정 및 저교정으로 부동시를 유발한 후 40 cm의 근거리에서 Titmus-fly stereotest 시표로 입체시를 측정하였다. 결과: 우위안 또는 비우위안에 구면렌즈를 부가하여 부동시를 유발한 경우, 가입도수의 증가에 따라 입체시는 감소하였으며 특히 (+)구면렌즈 가입에 따른 최초의 입체시 감소는 (-)구면렌즈 가입에 의한 입체시 감소보다 현저하였다. 또한 우위안에 유발시킨 부동시의 경우가 비우위안에 유발시킨 부동시보다 입체시 감소의 정도가 두드러졌다. 결론: 유발된 부동시에서 입체시는 비우위안을 완전교정하고 우위안에 (+)구면렌즈 도수를 증가시킬수록 두드러지게 감소하였다.

  • PDF

여대생의 콘택트렌즈 착용 및 관리 실태에 따른 안구건조증과 눈 피로 (Dry Eye Syndrome and Ocular Fatigue according to the Status of Contact Lens Wearing and Management among Female University Students)

  • 허선;김계하
    • 지역사회간호학회지
    • /
    • 제25권4호
    • /
    • pp.259-269
    • /
    • 2014
  • Purpose: The purpose of this study was to examine dry eye syndrome and ocular fatigue according to the status of contact lens wearing and management among female university students. Methods: The subjects were 195 female university students wearing contact lenses. Ocular Surface Disease Index (OSDI) and Virtual Reality Symptom Questionnaire (VRSQ) were used to determine the level of dry eye syndrome and ocular fatigue. The SPSS/WIN 21.0 program was used for analysis of data. Results: Significant differences in the level of dry eye syndrome were observed according to the period of case solution change (F=3.36, p=.037) and the reasons for the change of lens (F=4.56, p=.004). In ocular fatigue, significant differences were observed according to the price of lens (F=3.53, p=.031), rinse in storing lens in a case (t=-2.57, p=.011), and learning about contact lens (t=-2.01, p=.046). A significant positive correlation was observed between dry eye syndrome and ocular fatigue in the subjects. Conclusion: The results of this study show that some subjects have problems in wearing and management of contact lenses. Therefore, an education program related to contact lenses should be provided to contact lens wearers to improve the status of wearing and management of contact lenses.

콘텐트렌즈 착용자와 건성안 환자의 눈물 검사에 대한 비교 연구 (A comparative study of contact lens wearer with dry-eye patient on tear function tests)

  • 김순애;서은선;이영환;김재민
    • 한국안광학회지
    • /
    • 제9권2호
    • /
    • pp.301-312
    • /
    • 2004
  • 본 연구는 콘택트렌즈 착용자와 건성안 환자 사이의 관계를 비교하기 위해 시행되었다. 콘택트렌즈 착용자와 건성안 환자의 눈물 양과 질 및 안구 표면 상태와 자각증상을 조사하기 위해 TBUT, SIT, TIT, Rose-bengal staining and McMonnies dry eye symptom questionnaire를 시행하였다. 조사 대상자는 108명으로 3부류로 나누었는데 건성안 의심자 35명, 콘택트렌즈 착용자 38명, 대조군 35명이었다. 콘택트렌즈 착용자는 3그룹으로 나누었는데 12개월 이하, 13-48개월 이만, 48개월 이상으로 구분하였다. 본 연구 결과 시행한 모든 조사에서 콘택트렌즈 착용자와 건성안 환자 사이에 큰 차이가 없는 것으로 밝혀졌으며 콘택트렌즈 착용으로 건성안이 유도됨을 알 수 있었다.

  • PDF

콘택트렌즈 착용자와 비착용자의 건성안 설문조사 TERTC-DEQ의 활용 (Use of the Texas Eye Research and Technology Center Dry Eye Questionaire (TERTC-DEQ) as a Screening Survey for Contact Lens Wearers and Nonwearers)

  • 김재민;김용환;정주현
    • 한국안광학회지
    • /
    • 제12권4호
    • /
    • pp.127-131
    • /
    • 2007
  • 본 연구는 콘택트렌즈 착용자와 비착용자에서 건성안 증상의 분포와 증상의 일차 강도를 조사하고 McMonnies & Ho DEQ와 비교하기 위해 Texas Eye Research and Technology Center Dry Eye Questionnarire(TERTC-DEQ) 설문 조사를 수행하였다. 두 가지 건성안 설문조사는 46명의 콘택트렌즈 착용자와 47명의 비착용자를 대상으로 시행하였다. 콘택트렌즈 착용자는 McMonnies & Ho DEQ(6.5%)보다 TERTC-DEQ(52.2%)에서 더 높은 점수를 보였다. 비콘택트렌즈 착용자도 역시 McMonnies & Ho DEQ(2.1%)보다 TERTC-DEQ(19.1%)에서 더 높은 점수를 보였다. 안구의 자각증상(불편감, 건조감, 통증, 이물감과 가려움증)은 두 그룹에서 오후가 될수록 더 악화되었다. 본 연구에 의하면 TERTC-DEQ가 McMonnies & Ho DEQ와 비교하면 환자의 자각 증상을 효과적으로 평가하기 위한 첫 번째 선택 기법으로 제공될 것으로 사료된다. TERTC-DEQ는 효과적인 설문조사 기법으로 콘택트렌즈 관련 건성안 진단에 활용될 수 있을 것으로 사료된다.

  • PDF

Netspag Lens를 이용한 Mono vision에서 시력개선 효과에 대한 P-VEP 연구 (The Effects of Visual acuity increase in mono vision by the P-VEP study using Netspeg lens)

  • 김덕훈;배한용;김선태
    • 한국안광학회지
    • /
    • 제10권3호
    • /
    • pp.241-246
    • /
    • 2005
  • 본 연구는 굴절이상을 가진 피검자의 단안에서 Netspeg lens를 착용 후 시력 개선의 상태를 P-VEP의 파형 분석을 통해서 검증하고자 하였다. P-VEP는 3 channel의 Bausch Lomb system으로 기록하였다. 10명의 성인 피검자(남성 5인, 여성 5명; 평균 21세, 연령은 19세와 23세 사이)의 눈을 검사하였다. 피검자는 전신건강, 약물복용, 유전, 알레르기 그리고 안질환을 포함하는 문진 등을 조사하였다. 시력과 굴절검사는 Netspeg lens를 사용하여 피검자의 단안을 기록하였다. 피검자는 P-VEP 기록을 하는 동안 교정된 시력을 통해서 단안의 P-VEP 자극을 본다. 연구의 결과 Netspeg lens를 사용한 단안은 사용하지 않는 눈에 비해서 시력 결상이 선영하게 자각되었다. 한편 P-VEP 검사에서는 Netspeg lens를 사용한 눈이 높은 진폭 나타 내었다. 그러나 P-VEP의 장복시간은 오히려 늦게 나타났다. 그러나 P-VEP이 형태에서는 Netspeg lens를 사용한 눈이 안정된 파형을 유지하였다. 한편 오른 눈과 왼눈의 유의성은 거의 없었다. 따라서 본 연구에서는 Netspeg lens를 사용한 단안에서는 그렇지 않는 눈에 비해서 시력과 시기능이 기능이 우수함을 나타내었다.

  • PDF