Ultra Violet(UV) is gradually being replaced with LED instead of general UV lamps. However, the light efficiency of UV LED is still lower than that of the general lamp, and the light efficiency is also low. Due to the current environment and technical problems of UV lamps, the LED replacements are gradually being made. In this study, a new package design and analysis were performed to increase the lifetime and performance of UV LEDs. A new packaging for UV LED were designed and implemented. The new packaging for UV LED was constructed to improve light efficiency. And the electrical and optical characteristics were analyzed respectively. To improve the optical efficiency in UV LED package, the Al has been used based on high reflectivity and applying the optimal lens focusing. Compared to the existing silver Ag, the light efficiency was improved by about 30% or more, and it was confirmed that the light output degradation characteristic was improved by about 10% in the newly applied optical device chip.
Following the signing of the Paris Agreement on Climate Change (UNFCCC, 2015), the world is expanding greenhouse gas reduction activities through comprehensive participation that includes not only developed countries but also developing countries. Major countries around the world are placing high expectations on the effectiveness of total carbon emissions regulation through the carbon emissions market. However, in order to obtain carbon credits, third-party verification is required based on quantitative carbon reduction data. Accordingly, in this paper, we developed an AIoT high-efficiency street light for carbon emissions and conducted a performance analysis study to measure the luminous efficiency of the lighting fixture. To obtain carbon emissions rights, we used high-efficiency LED PKG, developed our own high-voltage PFC, and developed high-efficiency lighting fixtures capable of communication. For communication, the 2.4GHz LoRa method was adopted between the lighting fixture and the gateway. Lens design was conducted through simulation of Korea Expressway Corporation's standard streetlight types A, B, and C. The performance of the streetlight was verified as being more efficient than other existing products through the measurement of luminous efficiency by an accredited rating agency, and it is expected that carbon emissions rights will be obtained by reducing electrical energy through this.
Conceptual modeling is an important step for successful system development. It helps system designers and business practitioners share the same view on domain knowledge. If the work is successful, a result of conceptual modeling can be beneficial in increasing productivity and reducing failures. However, the value of conceptual modeling is unlikely to be evaluated uniformly because we are lack of agreement on how to elicit concepts and how to represent those with conceptual modeling constructs. Especially, designing relationships between components, also known as part-whole relationships, have been regarded as complicated work. The recent study, "Representing Part-Whole Relations in Conceptual Modeling : An Empirical Evaluation" (Shanks et al., 2008), published in MIS Quarterly, can be regarded as one of positive efforts. Not only the study is one of few attempts of trying to clarify how to select modeling alternatives in part-whole design, but also it shows results based on an empirical experiment. Shanks et al. argue that there are two modeling alternatives to represent part-whole relationships : an implicit representation and an explicit one. By conducting an experiment, they insist that the explicit representation increases the value of a conceptual model. Moreover, Shanks et al. justify their findings by citing the BWW ontology. Recently, the study from Shanks et al. faces criticism. Allen and March (2012) argue that Shanks et al.'s experiment is lack of validity and reliability since the experimental setting suffers from error-prone and self-defensive design. They point out that the experiment is intentionally fabricated to support the idea, as such that using concrete UML concepts results in positive results in understanding models. Additionally, Allen and March add that the experiment failed to consider boundary conditions; thus reducing credibility. Shanks and Weber (2012) contradict flatly the argument suggested by Allen and March (2012). To defend, they posit the BWW ontology is righteously applied in supporting the research. Moreover, the experiment, they insist, can be fairly acceptable. Therefore, Shanks and Weber argue that Allen and March distort the true value of Shanks et al. by pointing out minor limitations. In this study, we try to investigate the dispute around Shanks et al. in order to answer to the following question : "What is the proper value of the study conducted by Shanks et al.?" More profoundly, we question whether or not using the BWW ontology can be the only viable option of exploring better conceptual modeling methods and procedures. To understand key issues around the dispute, first we reviewed previous studies relating to the BWW ontology. We critically reviewed both of Shanks and Weber and Allen and March. With those findings, we further discuss theories on part-whole (or part-of) relationships that are rarely treated in the dispute. As a result, we found three additional evidences that are not sufficiently covered by the dispute. The main focus of the dispute is on the errors of experimental methods: Shanks et al. did not use Bunge's Ontology properly; the refutation of a paradigm shift is lack of concrete, logical rationale; the conceptualization on part-whole relations should be reformed. Conclusively, Allen and March indicate properly issues that weaken the value of Shanks et al. In general, their criticism is reasonable; however, they do not provide sufficient answers how to anchor future studies on part-whole relationships. We argue that the use of the BWW ontology should be rigorously evaluated by its original philosophical rationales surrounding part-whole existence. Moreover, conceptual modeling on the part-whole phenomena should be investigated with more plentiful lens of alternative theories. The criticism on Shanks et al. should not be regarded as a contradiction on evaluating modeling methods of alternative part-whole representations. To the contrary, it should be viewed as a call for research on usable and useful approaches to increase value of conceptual modeling.
This study is of investigation of refraction error, spectacles and contact lenses wearing state, visual acuity test, ophthalmologic common sense and vision care, using questionnaire study for 850 male and female high school students in Kunsan and Chongup City, Cheolla North Province. The results are as follows: 1. Among the 823 answerers, emmetropia is 18%, myopia is 55.1%, and hyperopia is 7%, respectively. 2. Among the 837 answerers, 381 students(45.5%) wear spectacles or contact lenses. Among the 381 students who wear spectacles or contact lenses, 78% wear only spectacles, 4% wear only contact lenses and 18% wears spectacles sometimes or contact lenses sometimes. 3. The places where the answerers had visual acuity test to wear spectacles or contact lenses are optical shop(64.7%), hospital(28.3%), unchecked(4.2%) and the others(2.7%). The places where the answerers had visual acuity test to change their spectacles or contact lenses are optical shop(82%), hospital(28.3%), unchecked(6.6%) and the others(1.9%). 4. As for the period of visual acuity test, from 6 months to one year is 54.1%, within 6 months is 9.2%, from one year to two years is 29.5%, and more than two years is 7.2%. 5. The contact lens wearers purchased their contact lenses at optical shops(94%) and at hospital(6%). 6. The reasons why they like wearing contact lenses are their appearance(51.2%), convenience in physical excercise(23.l%), lighter weight than spectacles(9.8%) and the others(15.7%). 7. As for the spectacles frame they like, plastic frame is 24.4%, gold or silver plated frame is 43.4%, coloured frame is 32.1%. 8. As for the considerations in choosing spectacles frame, their design is 37%, their quality is 36%, their price is 14.7% and their brand is 12.5%. 9. As for the period for changing spectacles, 10.5% is within 6 months, 57.3% is 6months to 1 year, 22.4% is 1 year to 2 months and 9.6% is more than 2 years. 10. There is a false fact, in Korea, that even though one has his poor eyesight, not wearing custom is helpful for the eyesight recovery. As for their conviction of the false fact, 10.5% of the answerers have 100% conviction, 22.5% of them have 22.5% conviction, 49.5% of them have 50% conviction and 17.5% of them don't have any conviction. 11. 48.5% of the answerers are interested in their vision care while 51.5% of them are not interested at all. As for the way of vision care, the vision-care way to keep enough distant when they are watching TV, when they are using computers and when they are reading, is 49% while the vision-care way such as hypogastric breathing or eye massage is 11%. And alimentotherapy is 4% and the rest who are not interested in vision care is 36%. 12. When they come to an age, the students who want vision correction operation are 45.9% while the students who do not want it are 27%. The students who do not have any idea about the operation are 27.1%
Purpose: In order to provide the fundamental information for the design development of RGP lenses and its clinical prescription, the corneal types of Korean twenties were analyzed according to corneal shapes, astigmatic degree, and the certain distance from the corneal apex. Methods: Corneal types of total 252 eyes in 20s were firstly classified, then their corneal radii from the certain distance from the corneal apex were measured by corneal topography and further analyzed based on the astigmatic degree. Results: Korean 20s' corneal types were classified as 14.3%(36 eyes) of round, 31.3%(79 eyes) of oval, 28.6%(72 eyes) of symmetric bow tie, 17.5%(44 eyes) of asymmetric bow tie, 8.3%(21 eyes) of irregular shapes. The round and oval typed corneas had mild astigmatic degree whereas the higher astigmatic degree in symmetric and asymmetric bow tie typed corneas were shown. The relative corneal radii of round and oval typed corneas at each distance from corneal apex were shown to consistently increase regardless of astigmatic degrees when they measured at certain distances from the corneal apex. However, the relative corneal radii of symmetric and asymmetric bow tie typed corneas within 1.0-1.5mm from the corneal apex were decreased, which showed steeper slope than it within 1.0 mm and somewhat different based on astigmatic degrees. Bigger change of corneal radii outer 3.5 mm from the corneal apex in symmetric bow tie typed corneas with astigmatism of 1.50-2.00 D and 2.25-2.75 D appeared. Conclusions: The consideration of radial change from the central cornea to peripheral cornea is necessary for manufacturing RGP lens and its prescription since they showed different change in corneal radii by corneal patterns and astigmatic degrees.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70