• Title/Summary/Keyword: Length structures

Search Result 2,255, Processing Time 0.026 seconds

Application of Long Gauge Fiber Optic Sensors to Construction Engineering Structures (장대 광변형 센서의 건설 구조물 적용)

  • 로드테니슨;안명운;김상환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10c
    • /
    • pp.61-78
    • /
    • 2001
  • Various kind of fiber optic gauge sensors are available that can be bonded to civil engineering structures such as bridges, dams, tunnels and pipelines. A new fiber optic long gauge has significant advantages over other fiber optic sensors. These gauges can vary in length from less than 10 cm up to 30 m and provide the structural engineer with accurate measurements of displacement. These displacements can be converted to strains by dividing the measurement by the long gauge length. Using new optical technology, the long gauge instrument developed by FOX-TEK can choose max. 30 meters of gauge length so as to measure the very early stress/strain correlation curve. And this gauge length to be extended up to 100 meter in 2002.

  • PDF

Effective Bond Length of FRP Sheets Externally Bonded to Concrete

  • Ben Ouezdou, Mongi;Belarbi, Abdeldjelil;Bae, Sang-Wook
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.2
    • /
    • pp.127-131
    • /
    • 2009
  • Strengthening and repair of concrete structures using externally bonded fiber reinforced polymer (FRP) composite sheets has been popular around the world during the last two decades. However, premature failure due to debonding of the FRP is one of the important issues still to be resolved. Numerous research studies have dealt with the debonding problem in terms of Effective Bond Length (EBL), however, determination of this length has not yet been completely assessed. This paper summarizes previous works on the EBL and proposes a new relationship of the EBL with the FRP stiffness based on the existing experimental data collected in this study.

Development Length of High-Strength Standard Hooked Bars (550MPa) in Nuclear Power Plant Structures (고강도철근(550MPa)의 원전구조물 적용을 위한 표준갈고리 정착설계)

  • Lee, Byung Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.99-100
    • /
    • 2018
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, it is permitted to use the high-strength(550MPa) hooked bars in design of development length, but there is no special equation for high-strength bars. In order to reflect the anchorage capacity and behavior properties of high-strength bars with large-diameter(43 & 57mm), it is necessary to develope the new development length equation for large-size and high-strength bars.

  • PDF

Development Length of High-Strength Straight Bars (550MPa) in Nuclear Power Plant Structures (고강도철근(550MPa)의 원전구조물 적용을 위한 직선철근의 정착설계)

  • Lee, Byung Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.110-111
    • /
    • 2018
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, it is permitted to use the high-strength(550MPa) straight bars in design of development length, but there is no special equation for high-strength bars. In order to reflect the anchorage capacity and behavior properties of high-strength straight bars with large-diameter(43 & 57mm), it is necessary to find the modified factor or develop the new development length equation for large-size and high-strength bars.

  • PDF

Reliability analysis of double-layer domes with stochastic geometric imperfections

  • Gordini, Mehrdad;Habibi, Mohammad Reza;Sheidaii, Mohammad Reza;Tahamouliroudsari, Mehrzad
    • Advances in Computational Design
    • /
    • v.2 no.2
    • /
    • pp.133-146
    • /
    • 2017
  • This study aimed to investigate the effect of initial member length an imperfection in the load carrying capacity of double-layer domes space structures. First, for the member length imperfection of each member, a random number is generated from a normal distribution. Thereupon, the amount of the imperfection randomly varies from one member to another. Afterwards, based on the Push Down analysis, the collapse behavior and the ultimate capacity of the considered structure is determined using nonlinear analysis performed by the OpenSees software and this procedure is repeated numerous times by Monte Carlo simulation method. Finally, the reliability of structures is determined. The results show that the collapse behavior of double-layer domes space structures is highly sensitive to the random distribution of initial imperfections.

Assessment of various nonlocal higher order theories for the bending and buckling behavior of functionally graded nanobeams

  • Rahmani, O.;Refaeinejad, V.;Hosseini, S.A.H.
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.339-350
    • /
    • 2017
  • In this paper, various nonlocal higher-order shear deformation beam theories that consider the size dependent effects in Functionally Graded Material (FGM) beam are examined. The presented theories fulfill the zero traction boundary conditions on the top and bottom surface of the beam and a shear correction factor is not required. Hamilton's principle is used to derive equation of motion as well as related boundary condition. The Navier solution is applied to solve the simply supported boundary conditions and exact formulas are proposed for the bending and static buckling. A parametric study is also included to investigate the effect of gradient index, length scale parameter and length-to-thickness ratio (aspect ratio) on the bending and the static buckling characteristics of FG nanobeams.

Structural System Development by Nonlinear Analysis of Polyhedron Curved Space Structure Using Quasicrystal System (준결정 시스템을 이용한 다면체 곡면 대공간구조의 비선형해석을 통한 구조시스템 개발)

  • Kim, Seung-Deog;Lee, Kyoung-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.125-132
    • /
    • 2016
  • This paper is a study on the nonlinear behavior of polyhedron curved space roof as building structures of quasicrystal system. The quasicrystal is made up of two kinds of parallel hexahedrons, and all the line elements of the parallelepiped have the same length. The quasicrystal design grid dome has a pentagonal symmetry and all members have the same length. This paper described form of design gird dome, and showed the analysis conditions. Also, The displacement-load curve is shown through the analysis and we grasped the flow of the load and forces through analysis of design grid dome applied quasicrystal system.

Natural Frequency and Mode Characteristics of Composite Pole Structures for Different Layup Sequences (복합소재 기둥 구조의 적층배열 변화에 따른 고유진동 및 모드 특성)

  • Kim, Gyu-Dong;Rus, Guillermo;Lee, Sang-Youl
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2013
  • The dynamic analysis of poles made of advanced composite materials is carried out for different length-thickness ratios and layup sequences. The numerical results using ABAQUS obtained for plates and shells are in good agreement with those reported by other investigators. The new results for laminated composite pole structures in this study mainly show the effect of the interactions between the radius-length ratio and other various parameters. The effect of fiber angles of long composite poles also investigated. Key observation points are discussed and a brief design guideline is given.

Study on the Fiber Bragg Grating Sensors for Smart Structures and Their Applications (스마트 구조물용 광섬유 격자센서 및 그 응용)

  • Kim Ki-Soo;Song Young-Chul;Pang Gi-Sung
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.115-118
    • /
    • 2004
  • In this paper, a Fiber Bragg Grating (FBG) sensor system for smart structures is described. FBGs are well-suited for long term and extremely severe experiments, where traditional strain gauges fail. In the system, a reflect wave-length measurement method which employs a tunable light source to find out the center wave-length of FBG sensor is used. We applied the FBG system to composite repairing structures and beam column joint of building structure. We also applied the system to nuclear energy power plant for structural integrity test to measure the displacement of the structure under designed pressure and to check the elasticity of the structure by measuring the residual strain. The system works very well and it is expected that it can be used for a real-time strain, temperature and vibration detectors as parts of smart structures.

  • PDF

Compressive performance with variation of yield strength and width-thickness ratio for steel plate-concrete wall structures

  • Choi, Byong-Jeong;Kim, Won-Ki;Kim, Woo-Bum;Kang, Cheol-Kyu
    • Steel and Composite Structures
    • /
    • v.14 no.5
    • /
    • pp.473-491
    • /
    • 2013
  • The primary objectives of this paper are to describe the buckling patterns and to determine the squash load of steel plate-concrete (SC) walls. The major variables in this study were the width-thickness (B/t) ratio and yield strength of surface steel plates. Six SC walls were tested, and the results include the maximum strength, buckling pattern of steel plates, strength of headed studs, and behavior of headed studs. Based on the test results, the effects of the B/t ratio on the compressive strength are also discussed. The paper also presents recommended effective length coefficients and discusses the effects of varying the yield strength of the steel plate, and the effects of headed studs on the performance of SC structures based on the test results and analysis.