• 제목/요약/키워드: Length of line

검색결과 2,375건 처리시간 0.03초

하악골 전산화단층사진촬영시 기준선에 관한 연구 (Reference line for computed tomogram of the mandible)

  • 유충현;김재덕
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.153-157
    • /
    • 2002
  • Purpose : This study was performed to determine the proper reference line for taking axial computed tomograms from which the good cross-sectional views can be reformatted by multiplanar reconstruction. Methods : Three dry mandibles with implanted gutta percha cones in the extracted socket were scanned axially according to 6 reference lines of 2 mandibular positions with computed tomogram Hitachi W550. The accuracy of measurements of the lengths of implanted gutta perch a cones in the each cross-sectional view reformatted from axial computed tomogram by multiplanar reconstruction was evaluated. Results: The difference between the measurements and the real length of implant was smallest in the bucco-lingual views reformatted from the axial views scanned according to the reference line of group V-a. The smaller the angle difference between reference line and occlusal line was, the smaller the difference between the measurements in the bucco-lingual views reformatted from axial views and the real length of implant. The majority of measured widths of implants in the bucco-lingually reformatted views were larger than the actual values. Conclusions : When the mandible is inclined within the limitation of gantry angle and scanned with the reference line coincident with occlusal plane, the bucco-lingual view can be reformatted without deformation of images from the axially scanned images.

  • PDF

VCO의 MSL길이가 발진특성에 미치는 영향 (Effects of the length the MSL on the oscillation characteristic of the VCO)

  • 이동희;정진휘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.721-724
    • /
    • 2001
  • In this paper, we present the effect the length the MSL(Microstrip Line) on the oscillation characteristic of the fabricated VCOs(Voltage Controlled Oscillator) designed and analyzed by RF circuit simulator Serenade(ANSOFT Co.) and fabricated by screen printing method on the alumina substrate. We have fabricated VCOs with 3 different MSL length and each MSL length of the VCO is 140mi1, 280mil and 560mi1. The oscillation frequency of each sample(VCO) was tuned to UHF band(750MHz∼900MHz) varying the capacitance. The experimental result shows the phase noise -82∼-97[dBc/Hz] at a 50 [kHz] offset frequency, the pushing figure 94∼318[kHz] at 3${\pm}$0.15[V] and the harmonics 13∼21 [dBc] between MSL length 140mi1s and 560mi1. The frequency and output variation width are 779∼898[MHz], -36∼-33[dBm] at MSL length 140mi1; 818∼836[MHz], -27.19∼-27.06[dBm] at 280mi1;751.54∼751.198[MHz],-33.44∼ -33.31[dBm] at 560mi1. we examined 3 VCOs oscillation characteristic difference through comparison with phase noise, oscillation power and frequency by control voltage change, harmonics and pushing figure for each sample.

  • PDF

Walking behaviors for stroke survivors: comparison between straight line and curved path

  • Hwang, Wonjeong;Choi, Bora;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권3호
    • /
    • pp.141-145
    • /
    • 2019
  • Objective: The purpose of this study was to compare walking conditions (straight line and curved path) on walking patterns in persons who had experienced hemiplegic stroke and to determine whether if they adapt their walking pattern and performances according to changes in environmental conditions. Design: Cross-sectional study. Methods: Forty-four hemiplegic stroke survivors participated in this study. This study measured walking performance in three different walking conditions, such as straight walking, the more-affected leg in the inner curve walking, and less-affected leg in the inner curve walking conditions, and a 2-dimentional gait analysis system was used as a primary measurement. This study also measured secondary clinical factors including the Timed Up-and-Go Test, the Trunk Impairment Scale, and the Dynamic Gait Index. Results: After analyzing, cadence and step length of the less-affected side, stride length in the more-affected side, and stride length in less-affected side were significantly different among the three different walking conditions in this study (p<0.05), but other temporospatial parameters were not significant. Cadence was the largest in the straight walking condition. Step length in the less-affected side, stride length in the more-affected side, and stride length in less-affected side were also the longest in the straight walking condition. Conclusions: The results of the study suggest that hemiplegic stroke survivors show walking adaptability according to changes in walking demands and conditions, and moreover, cadence and step and stride lengths were significantly different between straight and curved walking conditions.

다중 홉 광 버스트 교환망에서 종단간 수율 향상을 위한 홉 단위 우선 순위 증가 기법 (Hop-by-Hop Priority Increasing Scheme for Improving End-to-end Throughput in Multi-Hop OBS Networks)

  • 김병철;조유제
    • 대한전자공학회논문지TC
    • /
    • 제40권10호
    • /
    • pp.35-42
    • /
    • 2003
  • 본 논문에서는 광 버스트 교환 방식에서 사용되는 제어 패킷 처리 시간 보상 기법 및 자원 예약 기법을 분류하고 다중 홉 환경에서 대표적인 예약 방식인 OT/DR (Offset Time/Delayed Reservation) 기반 JET(Just-Enough-Time) 방식의 문제점인 Path length priority effect를 분석하였다. 그리고, 이러한 문제점을 해결하면서 입력 FDL(Fiber Delay Line)을 사용하여 홉 단위로 우선 순위를 증가시켜 종단간 수율을 개선시킬 수 있는 FDL/DR 방식 기반의 홉 단위 우선 순위 증가 기법을 제안하고 시뮬레이션을 통하여 성능을 비교 분석하였다. 시뮬레이션을 통한 성능 분석 결과 제안된 방식은 다중 홉 환경에서 path length priority effect로 인해 발생하는 기존 방식의 문제점을 개선하여 종단간 성능이 향상됨을 알 수 있었다.

Determination of stress state in formation zone by central slip-line field chip

  • Toropov Andrey;Ko Sung Lim
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권3호
    • /
    • pp.24-28
    • /
    • 2005
  • Stress state of chip formation zone is one of the main problems in metal cutting mechanics. In two-dimensional case this process is usually considered as consistent shears of work material along one of several shear surfaces, separating chip from workpiece. These shear planes are assumed to be trajectories of maximum shear stress forming corresponding slip-line field. This paper suggests a new approach to the constriction of slip-line field, which implies uniform compression in chip formation zone. Based on the given model it has been found that imaginary shear line in orthogonal cutting is close to the trajectory of maximum normal stress and the problem about its determination has been considered as well. It has been shown that there is a second central slip-line field inside chip, which corresponds well to experimental data about stress distribution on tool rake face and tool-chip contact length. The suggested model would be useful in understanding mechanistic problems in machining.

Automatic Segmentation of Retinal Blood Vessels Based on Improved Multiscale Line Detection

  • Hou, Yanli
    • Journal of Computing Science and Engineering
    • /
    • 제8권2호
    • /
    • pp.119-128
    • /
    • 2014
  • The appearance of retinal blood vessels is an important diagnostic indicator of serious disease, such as hypertension, diabetes, cardiovascular disease, and stroke. Automatic segmentation of the retinal vasculature is a primary step towards automatic assessment of the retinal blood vessel features. This paper presents an automated method for the enhancement and segmentation of blood vessels in fundus images. To decrease the influence of the optic disk, and emphasize the vessels for each retinal image, a multidirectional morphological top-hat transform with rotating structuring elements is first applied to the background homogenized retinal image. Then, an improved multiscale line detector is presented to produce a vessel response image, and yield the retinal blood vessel tree for each retinal image. Since different line detectors at varying scales have different line responses in the multiscale detector, the line detectors with longer length produce more vessel responses than the ones with shorter length; the improved multiscale detector combines all the responses at different scales by setting different weights for each scale. The methodology is evaluated on two publicly available databases, DRIVE and STARE. Experimental results demonstrate an excellent performance that approximates the average accuracy of a human observer. Moreover, the method is simple, fast, and robust to noise, so it is suitable for being integrated into a computer-assisted diagnostic system for ophthalmic disorders.

Effect of line and floor type on growth performance and feather characterization during the growth period of White Roman geese

  • Lin, Min Jung;Chang, Shen Chang;Chen, Tzu Jou;Lin, Wei Chih;Peng, Shao Yu;Lee, Tzu Tai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권9호
    • /
    • pp.1455-1462
    • /
    • 2020
  • Objective: The purpose of this study was to investigate whether goose growth and feather characteristics are influenced by their line and feeding surroundings, inclusive of floor materials and types, since there are no reports regarding these factors. Methods: The 240 White Roman geese which were hatched and sex identified came from 3 commercial goose farms. They were randomly distributed to 24 pens depending on a completely random design. The study continued for 13 weeks and included 3 lines of commercial geese and 2 floor types (cement strip floor [CSF] or cement floor [CF]). Results: The day one gosling weight from A farm was lower than other two farms (96 g vs 107 and 115 g; p<0.001). Afterwards, the body weight, back length, keel length, chest girth and main wing feather length among 3 farms showed no significance difference prior to 12 weeks. The CF group showed heavier body weight, shorter back length, longer keel length, shorter chest girth and shorter main wing feather length than the CSF group prior to 12 weeks. The down weight in the CF was heavier than the CSF group (57.1 g vs 41.8 g; p<0.01) prior to 13 weeks. Conclusion: The body weight showed the positive relations for dry feather weight (r = 0.59), down weight (r = 0.69), percent of the down weight of live body weight prior to 13 weeks (r = 0.61).

1D 측선에 의한 절리 자료에 대한 편향 보정 기법에 관한 연구 (A study of the Sampling Bias Correction on Joint Data from 1D Survey Line)

  • 엄정기
    • 터널과지하공간
    • /
    • 제13권5호
    • /
    • pp.344-352
    • /
    • 2003
  • 시추공 또는 선형조사선과 같은 1D측선에서 측정된 절리 자료의 샘플링 편향을 보정하는 절차를 기술하였다. ID 측선에서 절리가 관측될 수 있는 확률은 측선 방향에 대한 절리의 상대적인 방향 이외에도 절리 크기, 절리 모양 및 측선 길이 등의 복합적 요인에 의하여 결정될 수 있다. 본 연구에서는 절리의 모양을 원판형이라 가정하고 절리의 방향 및 크기에 의하여 나타날 수 있는 절리 자료의 방향 편향 효과를 동시에 보정할 수 있는 방법론을 제시하고, 현장적용을 통하여 방향 편향 보정이 절리군의 방향분포에 미치는 영향에 대하여 고찰하였다. 또한, 유한 길이의 측선으로부터 산정된 절리군의 간격분포는 샘플링 영역인 측선 길이에 따라 다르게 나타날 수 있으며, 이와 같은 간격 편향에 대한 보정절차를 기술하였다.

길 원형을 위한 상반신의 체형 연구 - 한국 성인 여성을 대상으로 - (A Study on the Somatotype of the Upper Body for the Women's Bodice Pattern)

  • 이순원;남윤자
    • 한국의류학회지
    • /
    • 제15권4호
    • /
    • pp.341-349
    • /
    • 1991
  • This study was done to provide basic data for clothing design and thus to contribute to the academic development of the clothing and textile area. The focus of this study was to charac­terize the somatotype based on each individual's lateral view. For this purpose, firstly, categorization of the subjects based on their lateral view and definition of each category, secondly, characterization of each somatotype, and thirdly, sugges­tion of the deterministic criteria of each category were complished. The subjects in this study were female college students of 18 to 26 year-old whose somatotypes were comparatively invariable after cessation of physical growth. The metrical items characterizing upper body lateral view were chosen. Data were collected through Anthropometry and Photometry and analyzed by Factor analysis. The results were as follows; 1. Each subject's side view contour was classified as straight type, lean-back type, bend­forward type, and swayback according to its position to the relative plumb line. Straight type was defined as the type in which the plumb line passes through the lobe of the ear, the shoulder joint, and the mid abdominal region laterally. Lean-back type positioned the plumb line more posteriorly than straight type. Bend-forward type positioned the plumb line more anteriorly than straight type. Swayback positioned the plumb line at about the same line as straight type. And curvature of side view contur was more prominent in this type than in straight type. 2. Seven factors were figured out. The first factor was representing upperbody volume, and the second factor was representing size, the third factor was horizontal distance from lateral view representing size view contour. The fourth factor was front body length, the fifth factor was back body length. The sixth factor was shoulder length and shoulder width representing shoulder shape. The seventh factor was the bust shape.

  • PDF

끝이 단락된 결합선로를 이용한 전력 분배기의 초소형화 (A New Reduced-Sized Lumped Distributed Power Divider Using The Shorted Coupled-line Pair)

  • 강인호;최재교
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.283-287
    • /
    • 2003
  • A new method to miniaturize ${\lambda}/4$ transmission line of power divider is proposed. The method utilizes simple combination of the shorted coupled-line pair instead of the transmission line with very high impedance and shunt lumped capacitors. The length of ${\lambda}/4$ transmission line of power divider is about 16% over the conventional power divider at 1 GHz.

  • PDF