• Title/Summary/Keyword: Length

Search Result 38,812, Processing Time 0.053 seconds

Step Length Estimation on a Slope Using Accelerometers and a Barometer (가속도계와 기압계를 이용한 경사면에서의 보행 거리 추정)

  • Hung, Tran Nhat;Suh, Young Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.334-340
    • /
    • 2013
  • Using a relationship between step length and accelerometer output, step length can be estimated. In this paper, we propose a new step length estimation algorithm, which can be used both for the plane and the slope by compensating the slope angle. The slope angle is estimated using a barometer and the slope angle is compensated by observing how the slope affects the step length estimation. The proposed algorithm is verified using five adult man walking data, where the average length error is about 3% regardless of the slope.

Experimental study on development length of prestressing strand in pretensioned prestressed concrete members (프리텐션 프리스트레스트 콘크리트 부재의 정착길이 평가)

  • Kim, Ui-Seong
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.49
    • /
    • pp.84-91
    • /
    • 2009
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

  • PDF

A Study on the Statistical characteristics of Hagul Graphic Image Date (한글 Graphic Image Date의 통계적 특성에 관한 연구)

  • 김재석;김재균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.2
    • /
    • pp.15-22
    • /
    • 1980
  • For efficient coding of graphic image data, the statistical characteristics for both Korean lettered images and English lettered images are measurpd and co mpared. Also, the measured run length distribution is compared with the run length distribution hased on Markov model. It is shown that the measured white run length distribution is more Bike a negative - power distribution than an exponential distribution . This fact is stronger in the Korean lettered images than is the English lettered images, The performances of four typical run length codes are compared for the same set of graphic data files,, and it is shown that the codes perform better in the Korean ]entered images :hart In Eng]isle lettered images.

  • PDF

Change of Spray Characteristics with Mixing Port Length of Y-Jet Atomizers (Y-Jet 노즐에서의 혼합관 길이변화에 따른 분무특성 연구)

  • 송시홍;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3021-3031
    • /
    • 1994
  • Experiments have been performed to find out the effect of the mixing port length of Y-jet atomizers on the spray performance, using air and water as the test fluids. Water and air flow rates and drop sizes were measured at each injection pressure condition for different mixing port length. The air flow rate was almost unaffected by the change of the mixing port length. However, the water flow rate was relatively susceptible to the change of the mixing port length. The mixing point pressure was very much influenced by the mixing port length. Variations of spatial distribution of Sauter Mean Diameter (SMD, $D_{32}$) and the cross-section-averaged SMD ($D_{32,m}$) with different mixing port length and air/water mass flow rate ratio were examined. Generally, when the mixing port length was reduced, the mean drop size decreased and became spatially even.

Effects of Specimen Length on Flexural Compressive Strength of Concrete (부재의 길이가 콘크리트의 휨압축강도에 미치는 영향)

  • 김진근;이성태;이태규
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.63-71
    • /
    • 1999
  • In evaluating the ultimate strength of a section for a reinforced concrete flexural member, the effect of member length is not usually considered, even though the strength tends to decrease with increase of member length. In this paper the influence of specimen length on flexural compressive strength of concrete was evaluated. For this purpose, a series of C-shaped specimens subjected to axial compression and bending moment were tested using four different length-to-depth ratios (from 1,2,3 and 4) of specimens with compressive strength of 590 kgf/$\textrm{cm}^2$. Results indicate that for the region of h/c <3.0 the reduction in flexural compressive strength with increase of length-to-depth ratios was apparent. A model equation was depth of an equivalent rectangular stress block was larger than that by ACI. It was also founded that the effect of specimen length on ultimate strain was negligible. Finally more general model equation is also suggested.

Optimization of a Thermally Asymmetric Rectangular Fin: Based on Fixed Fin Height

  • Kang, Hyung-Suk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.3
    • /
    • pp.145-151
    • /
    • 2005
  • A thermally asymmetric straight rectangular fin is analysed and optimized using the two-dimensional separation of variables method. The optimum heat loss is presented as a function of bottom to top Biot number ratio, fin base length and top Biot number. Decreasing rate of the optimum fin length with the increase of the fin base length is listed. The optimum fin tip length is shown as a function of bottom to top Biot number ratio, fin base length and tip to top Biot number ratio. One of the results shows that the optimum heat loss and the actual optimum fin length decrease while the optimum fin tip length increases as the fin base length increases.

Experimental Study on Development Length of Prestressing Strand in Pretensioned Prestressed Concrete Members (프리텐션 프리스트레스트 콘크리트 부재의 정착길이 정가)

  • Kim, Eui-Sung
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.115-121
    • /
    • 2008
  • By bond mechanism between the prestressing strand and the concrete surrounding it, the effective force of prestressing must be transferred to the concrete entirely. The distance required to transfer the effective force of prestressing is called the transfer length, and the development length is the bond length required to anchor the strand as it resists external loads on the member. Transfer length was determined from the concrete strain profile at the level of the strands at transfer and development length was determined from various external loading lengths and compared with current code equation. Through the test results, bond failure is predicted based on the distress caused by cracks when they propagate within the transfer zone of prestressing strand. The current code equation was found to be conservative in comparison with the measured value.

Study on Atomization Characteristics of Shear Coaxial Injectors (전단동축형 분사기들의 미립화 특성에 대한 연구)

  • Ahn, Jonghyeon;Lee, Keunseok;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.26 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • Six shear coaxial injectors with different recess length and taper angle were manufactured. Cold-flow tests on the injectors were performed at room temperature and pressure using water and air as simulants. By changing the water mass flow rate and air mass flow rate, spray images were taken under single-injection and bi-injection. Breakup length and spray angle were analyzed from instantaneous and averaged spray images using image processing techniques. For all the injectors, the breakup length generally decreased as the momentum flux ratio increased at the same gas mass flow rate. The injectors with 7.5° taper angle usually had the longest breakup length and the smallest spray angle. When the taper angle was 15° or more, it hardly affected breakup length and spray angle. The recess length did not influence breakup length but its effect on spray angle depended on the taper angle.

A WEAKER NOTION OF THE FINITE FACTORIZATION PROPERTY

  • Henry Jiang;Shihan Kanungo;Hwisoo Kim
    • Communications of the Korean Mathematical Society
    • /
    • v.39 no.2
    • /
    • pp.313-329
    • /
    • 2024
  • An (additive) commutative monoid is called atomic if every given non-invertible element can be written as a sum of atoms (i.e., irreducible elements), in which case, such a sum is called a factorization of the given element. The number of atoms (counting repetitions) in the corresponding sum is called the length of the factorization. Following Geroldinger and Zhong, we say that an atomic monoid M is a length-finite factorization monoid if each b ∈ M has only finitely many factorizations of any prescribed length. An additive submonoid of ℝ≥0 is called a positive monoid. Factorizations in positive monoids have been actively studied in recent years. The main purpose of this paper is to give a better understanding of the non-unique factorization phenomenon in positive monoids through the lens of the length-finite factorization property. To do so, we identify a large class of positive monoids which satisfy the length-finite factorization property. Then we compare the length-finite factorization property to the bounded and the finite factorization properties, which are two properties that have been systematically investigated for more than thirty years.

The Resolving Method of Graft-Tunnel Mismatch in Arthroscopic ACL Reconstruction Using Bone-Patellar Tendon-Bone Graft (골-슬개건-골을 이용한 관절경적 전방십자인대 재건술시 이식물-터널 길이의 부조화를 줄이는 방법)

  • Cho, Se-Hyun;Park, Hyung-Bin;Ha, Sung-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.97-101
    • /
    • 1999
  • Purpose : The purpose of this study is to prevent thc graft-tunnel mismatch by measuring the patellar tendon length, intertunnel distance, tibial tunnel length and by obtaining appropriate bone block length. Materials and Methods : Authors analyzed 15 patients who had taken the anterior cruciate ligament reconstruction from March 1997 to June 1999. Tibial guide was always set on the "endo" $40^{\circ}$ position(Acufex, MA, USA). We measured the following indices, intertunnel distance(X), tibial tunnel length(T), patellar tendon length(N), tibia bone plug length(Y). Both of the femoral tunnel length(F) and the patellar bone plug length(P) were made in 25mm. The appropriate tibial bone plug length was simply calculated by subtracting the patellar tendon length from the sum of the intertunnel distance and thc tibial tunnel length(Y=X+T-N). Results : The average indices were as follows ; the intertunnel distance(X) was $23.4{\pm}1.4mm$, the tibial tunnel length(T) was $43.6{\pm}1.7mm$, the patellar tendon length was $40{\pm}2.4mm$, and the tibia bone plug length was $27{\pm}2.4mm$. Conclusion : In authors' endoscopic technique, establishment of individually determined optimal tibial bone plug length, based on total tunnel length and patellar tendon length could prevent the problem of graft-tunnel mismatch.

  • PDF