• Title/Summary/Keyword: Left-handed

Search Result 280, Processing Time 0.025 seconds

Design of a Dual Band High PAE Power Amplifier using Single FET and CRLH-TL (Single FET와 CRLH 전송선을 이용한 이중대역 고효율 전력증폭기 설계)

  • Kim, Seon-Sook;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.2
    • /
    • pp.56-61
    • /
    • 2010
  • In this paper, high efficient power amplifier with dual band has been realized. Dual band power amplifier have used modify stub matching for single FET, center frequency 2.14GHz and 5.2GHz respectively. The dual-band operation of the CRLH TL is achieved by the frequency offset and the nonlinear phase slope of the CRLH TL for the matching network of the power amplifier. Because the control of the all harmonic components is very difficult m dual-band, we have managed only the second- and third-harmonics to obtain the high efficiency with the CRLH TL in dual-band. Dual-band characteristics in the output has to balance. Two operating frequencies are chosen at 2.14 GHz and 5.2 GHz in this work. The measured results show that the output power of 28.56 dBm and 29 dBm was obtained at 2.14 GHz and 5.2 GHz, respectively. At this point, we have obtained the power-added efficiency (PAE) of 65.824 % and 69.86 % at two operation frequencies, respectively.

A case of Posterior Cortical Atrophy Presenting with Features of Atypical Dementia (비전형적 치매양상을 보이는 후부대뇌피질위축 증례보고)

  • Park, Kee Hyung;Kim, Sung-Wan;Shin, Dong-Jin;Park, Hyun-Mi;Lee, Yeong-Bae;Seung, Young-Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.1
    • /
    • pp.46-53
    • /
    • 2008
  • Posterior cortical atrophy(PCA) is a presenile dementia that presents primarily with signs and symptoms of cortical visual dysfunction, while memory is relatively preserved until the late stage of the disease. We report a patient with PCA, confirmed by brain magnetic resonance imaging (MRI) and $F^{18}$-fluorodeoxyglucose positron emission tomography(FDG PET). A 58-year-old right-handed woman presented initially with visual dimness and difficulty finding things around her. She had partial Balint's syndrome, partial Gerstmann syndrome, and idiomotor apraxia. She also had a mild memory disturbance, but preserved insight of her disease. Neuropsychological evaluation showed decreased parietal and left temporal functions bilaterally. Brain MRI and $F^{18}$-FDG PET revealed typical bilateral occipitoparietal atrophy and hypometabolism, which were slightly worse on the right side. Cholinesterase inhibitor administration for 6 months improved the memory impairment slightly, but not the cortical visual dysfunction. This is a typical case of PCA, confirmed by neurologic signs and imaging findings.

  • PDF

The Difference of Cortical Activation Pattern According to Motor Learning in Dominant and Non.dominant Hand: An fMRI Case Study (우성과 비우성 손에서의 운동학습으로 나타나는 뇌 활성도 차이: fMRI 사례 연구)

  • Park, Ji-Won;Jang, Sung-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.81-87
    • /
    • 2009
  • Purpose: Human brain was lateralized to dominant or non-dominant hemisphere, and could be reorganized by the processing of the motor learning. We reported four cases which showed the changes of the cortical activation patterns resulting from two weeks of training with the serial reaction time task. Methods: Four right-handed healthy subjects were recruited, who was equally divided to two training conditions (right hand training or left hand training). They were assigned to train the serial reaction time task for two weeks, which should press the corresponding four colored buttons as fast as accurately as possible when visual stimulus was presented. Before and after two weeks of training, reaction time and function magnetic resonance image (fMRI) was acquired during the performance of the same serial reaction time task as the training. Results: The reaction time was significantly decreased in all of subjects after training. Our fMRI result showed that widespread bilateral activation at the pre scanning was shifted toward the focused activation on the contralateral hemisphere with progressive motor learning. However, the bilateral activation was still remained during the performance of the non-dominant hand. Conclusion: These findings showed that the repetitive practice of the serial reaction time task led to increase the movement speed and accuracy, as described by motor learning. Such motor learning induced to change the cortical activation pattern. And, the changed pattern of the cortical activation resulting from motor learning was different each other in accordance with the hand dominance.

  • PDF

A Solar Stationary Type IV Radio Burst and Its Radiation Mechanism

  • Liu, Hongyu;Chen, Yao;Cho, Kyungsuk;Feng, Shiwei;Vasanth, Veluchamy;Koval, Artem;Du, Guohui;Wu, Zhao;Li, Chuanyang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.52.2-53
    • /
    • 2018
  • A stationary Type IV (IVs) radio burst was observed on September 24, 2011. Observations from the Nançay RadioHeliograph (NRH) show that the brightness temperature (TB ) of this burst is extremely high, over 10^11K at 150 MHz and over 10^8K in general. The degree of circular polarization (q ) is between -60%~-100%, which means that it is highly left-handed circularly polarized. The flux-frequency spectrum follows a power-law distribution, and the spectral index is considered to be roughly -3~-4 throughout the IVs. Radio sources of this event are located in the wake of the coronal mass ejection and are spatially dispersed. They line up to present a formation in which lower-frequency sources are higher. Based on these observations, it is suggested that the IVs was generated through electron cyclotron maser emission.

  • PDF

The Influence of Different Objects and Target Locations of Dominant Hand on the Non-Dominant Hand Movement Kinematics in Bimanual Reaching (양손으로 물체 옮기기 과제 수행 시 우세손이 옮기는 물체의 종류와 목표점의 위치 변화가 비우세손의 팔뻗기 동작에 미치는 영향)

  • Kim, Min-Hee;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.15 no.3
    • /
    • pp.44-52
    • /
    • 2008
  • The purpose of this study was to investigate the effects of different objects and target location of dominant hand on the non-dominant hand movement kinematics in a bimanual reaching task. Fifteen right-handed volunteers were asked to reach from same starting point to the different target point of right and left hand with grasping the objects of different size. Independent variables were 1) three different object types (small mug cup, name pen, and PET bottle), and 2) three different target locations (shorter distance, same distance, and longer distance than the non-dominant hand) of the dominant hand. Dependent variables were movement time (MT), movement distance (MD), movement mean velocity ($MV_{mean}$), and movement peak velocity ($MV_{peak}$) of the non-dominant hand. Repeated measures two-way analysis of variance (ANOVA) was used to test for differences in the non-dominant hand movement kinematics during bimanual reaching. The results of this study were as follows: 1) MT of the non-dominant hand was increased significantly when traveling with grasping the mug cup and reaching the far target location, and was decreased significantly when traveling with grasping the PET bottle and reaching the near target location of the dominant hand. 2) MD of the non-dominant hand was significantly increased during reaching the far target location, and significantly decreased during reaching the near target location with dominant hand. 3) $MV_{mean}$ of the non-dominant hand was increased significantly when traveling with grasping the PET bottle, and was decreased significantly when traveling with grasping the mug cup of the dominant hand. Therefore, it can be concluded that the changes of the ipsilateral hand movement have influence on coupling of the contralateral hand movement in bimanual reaching.

  • PDF

Design of a Metamaterial-Based Compact Dual-Band 3-way Power Divider for Lighter L-band Military Satellite Transceivers (L대역 군위성 중계기 경량화를 위한 메타재질기반 소형 이중대역 3분기 전력분배기의 설계)

  • Kahng, Kyung-Seok;Yang, Inkyu;Jang, Kyeong-Nam;Lee, Hosub;Lee, Hyoung-Jong;Kahng, Sungtek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1712-1718
    • /
    • 2013
  • This paper proposes a compact dual-band 3-way power divider that helps lowering the weight of a transceiver for the L-band or multi-purpose satellite communication. Instead of the multi stages or tapering which ends up with loss accumulation and size-growth, the non-linear dispersive phases from the metamaterial CRLH(composite right and left-handed) properties are obtained by the accurate formulation and implemented by the short transmission line segments. Firstly, the CRLH dual-band two-way unequal power divider and equal power divider are separately designed. And then, the input of the two-way equal power divider is plugged in the output port of the unequal one, and the entire geometry is slightly adjusted for the desirable performance. The circuit analysis and full-wave simulation are used to predict the frequency responses and validated by the measurement of the prototype. Besides, the size-reduction effect is addressed.

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

Replication origins oriGNAI3 and oriB of the mammalian AMPD2 locus nested in a region of straight DNA flanked by intrinsically bent DNA sites

  • Balani, Valerio Americo;De Lima Neto, Quirino Alves;Takeda, Karen Izumi;Gimenes, Fabricia;Fiorini, Adriana;Debatisse, Michelle;Fernandez, Maria Aparecida
    • BMB Reports
    • /
    • v.43 no.11
    • /
    • pp.744-749
    • /
    • 2010
  • The aim of this work was to determine whether intrinsically bent DNA sites are present at, or close to, the mammalian replication origins oriGNAI3 and oriB in the Chinese hamster AMPD2 locus. Using an electrophoretic mobility shift assay and in silico analysis, we located four intrinsically bent DNA sites (b1 to b4) in a fragment that contains the oriGNAI3 and one site (b5) proximal to oriB. The helical parameters show that each bent DNA site is curved in a left-handed superhelical writhe. A 2D projection of 3D fragment trajectories revealed that oriGNAI3 is located in a relatively straight segment flanked by bent sites b1 and b2, which map in previously identified Scaffold/Matrix Attachment Region. Sites b3 and b4 are located approximately 2 kb downstream and force the fragment into a strong closed loop structure. The b5 site is also located in an S/MAR that is found just downstream of oriB.

Design of the Miniaturized UWB BandPass Filter Using the 1 Unit of CRLH-TL (일단 CRLH 전송선 구조를 이용한 소형 초광대역 대역 통과 여파기의 설계)

  • Ju, Jeong-Ho;Kahng, Sung-Tek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.12
    • /
    • pp.1402-1407
    • /
    • 2007
  • This paper presents a new design method of the Ultra-Wide-Band BandPass Filter using the CRLH-TL(Composite Right- and Left-Handed Transmission-line) having the Metamaterials' properties. Instead of the periodic type or many cells of the CRLH-TL, only the unit cell is used to miniaturize the target component, which can not be realized by the conventional quarter guided-wavelength resonator-based filters. Particularly, the strong coupling essential to the Ultra Wide Band is enabled by the interdigital coupled lines between the grounded stubs. The proposed design scheme is validated by the electromagnetic simulation and measurement of the fabricated filter which shows the total size of 'the guided-wavelength/9.4', the 100 % fractional bandwidth for the UWB, the insertion loss of less than 1 dB and the flat group-delay.

Design of Dual-band Power Amplifier using CRLH of Metamaterials (메타구조의 CRLH를 이용한 이중대역 전력증폭기 설계)

  • Ko, Seung-Ki;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.12
    • /
    • pp.78-83
    • /
    • 2010
  • In this paper, a novel dual-band power amplifier using metamaterials has been realized with one RF GaN HEMT diffusion metal-oxide-semiconductor field effect transistor. The CRLH TL can lead to metamaterial transmission line with the dual-band tuning capability. The dual-band operation of the CRLH TL is achieved by the frequency offset and the nonlinear phase slope of the CRLH TL for the matching network of the power amplifier. We have managed only the second- and third-harmonics to obtain the high efficiency with the CRLH TL in dual-band. Also, the proposed power amplifier has been realized by using the harmonic control circuit for not only the output matching network, but also the input matching network for better efficiency. Two operating frequencies are chosen at 900 MHz and 2140 MHz in this work. The measured results show that the output power of 39.83 dBm and 35.17 dBm was obtained at 900 MHz and 2140 MHz, respectively. At this point, we have obtained the power-added efficiency (PAE) and IMD of 60.2 %, -23.17dBc and 67.3 %, -25.67dBc at two operation frequencies, respectively.