• 제목/요약/키워드: Left to right ratio

검색결과 589건 처리시간 0.026초

Seismic response evaluation of 154 kV transformer porcelain bushing by shaking table tests

  • Chun, Nakhyun;Jeon, Bubgyu;Kim, Sungwan;Chang, Sungjin;Son, Suwon
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.155-165
    • /
    • 2022
  • The use of electricity and communication between electronic devices is increasing daily, which makes the stability of electrical power supply vital. Since the 1990s, large earthquakes have occurred frequently causing considerable direct damage to electrical power facilities as well as secondary damage, such as difficulty in restoring functions due to the interruption of electric power supply. Therefore, it is very important to establish measures to protect electrical power facilities, such as transformers and switchboards, from earthquakes. In this study, a 154 kV transformer whose service life had expired was installed on the base fabricated by simulating the field conditions and conducting the shaking table tests. The dynamic characteristics and seismic behavior of the 154 kV transformer were analyzed through the resonance frequency search test and seismic simulation test that considers the front, rear, left, and right directions. Since the purpose of this study is to analyze the acceleration amplification in the bushing due to the acceleration amplification, the experimental results were analyzed focusing on the acceleration response and the converted acceleration amplification ratio rather than the failure due to the displacement response of the transformer. The seismic force amplification at the transformer bushing was evaluated by simulating the characteristics of electrical power facilities in South Korea, and compared with the IEC TS 61463 acceleration amplification factor. Finally, the amplification factor at zero period acceleration (ZPA) modified for each return period was summarized. The results of this study can be used as data to define the amplification factor at ZPA of the transformer bushing, simulating the characteristics of electrical power facilities in Korea.

A Novel, Deep Learning-Based, Automatic Photometric Analysis Software for Breast Aesthetic Scoring

  • Joseph Kyu-hyung Park;Seungchul Baek;Chan Yeong Heo;Jae Hoon Jeong;Yujin Myung
    • Archives of Plastic Surgery
    • /
    • 제51권1호
    • /
    • pp.30-35
    • /
    • 2024
  • Background Breast aesthetics evaluation often relies on subjective assessments, leading to the need for objective, automated tools. We developed the Seoul Breast Esthetic Scoring Tool (S-BEST), a photometric analysis software that utilizes a DenseNet-264 deep learning model to automatically evaluate breast landmarks and asymmetry indices. Methods S-BEST was trained on a dataset of frontal breast photographs annotated with 30 specific landmarks, divided into an 80-20 training-validation split. The software requires the distances of sternal notch to nipple or nipple-to-nipple as input and performs image preprocessing steps, including ratio correction and 8-bit normalization. Breast asymmetry indices and centimeter-based measurements are provided as the output. The accuracy of S-BEST was validated using a paired t-test and Bland-Altman plots, comparing its measurements to those obtained from physical examinations of 100 females diagnosed with breast cancer. Results S-BEST demonstrated high accuracy in automatic landmark localization, with most distances showing no statistically significant difference compared with physical measurements. However, the nipple to inframammary fold distance showed a significant bias, with a coefficient of determination ranging from 0.3787 to 0.4234 for the left and right sides, respectively. Conclusion S-BEST provides a fast, reliable, and automated approach for breast aesthetic evaluation based on 2D frontal photographs. While limited by its inability to capture volumetric attributes or multiple viewpoints, it serves as an accessible tool for both clinical and research applications.

학령기 아동의 시력저하 실태 및 관련 요인 (Factors Related to Vision Disturbances in the Elementary School-Age Children)

  • 신희선;오진주
    • Child Health Nursing Research
    • /
    • 제8권2호
    • /
    • pp.164-173
    • /
    • 2002
  • The vision disturbances of school-age children has been recognized as and important school health problem. The purpose of this study is to describe the current status of the visual health and to explore the related factors for the decrease in visual acuity in the elementary school age children. The study subjects were 697 children (Boys: 338, Girls: 359) of 4th to 6th grade in two school in urban area. The visual acuity data of the school health examination in 1999 and 2000 were utilized for analysis. The questionnaire for children and parents was used for survey. The findings were as follows. 1. The prevalance rate of the children with the visual acuity less than 0.7 on the left eye were 26.84% ( Grade 4), 31.30% (Grade 5), and 38.39% (Grade 6). The rate on the right eye were 28.31% (Grade4), 30.37% (Grade 5), and 37.92% (Grade 6). There was a significant difference in the rate of the visual acuity less than 0.7 according to grade (p<.01). 2.The rate of visual acuity decrease was 40.12%. 3. The factors related to the decrease in the visual acuity were grade, sex, genetic factor, posture, and the awareness of the visual acuity. There was more decrease in the visual acuity when the children were in higher grade (O.R= 1.06), girls (O.R=2.29). Children having parents with better vision (Father: O.R=1.26; Mother O.R= 1.25) showed better vision. On the other hand, when the children have siblings with glasses, there was more decrease in the visual acuity (O.R=2.31). Students with good posture during study (sitting on the chair) and watching TV to the lower direction showed less decrease in the visual acuity. Also, when the students know their visual acuity, the rate of decrease were lower. The variables which odds ratio were statistically significant were sex (p<.01), siblings with glasses (p <.01), and awareness of visual acuity (p<.01).

  • PDF

Validation of Age Estimation Methods Using Pulpal Volume Changes in Radiographs for Korean Adults

  • Lee, Tae-Hoon;Hong, Jung-Hun;Lee, Sang-Seob;Kwon, Jeong-Seung;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • 제39권2호
    • /
    • pp.69-77
    • /
    • 2014
  • Purpose: It aims to verify the applicability of existing age estimation methods derived from data of foreign population groups to Korean population groups. Moreover it is to suggest a new way applicable to practical age estimation on the basis of newly calculated regression formulae from data of Korean population groups and develop a subsidiarily applicable method to the existing method. Methods: Ratio of pulp cavity to dental crown was calculated by measuring the height and width of dental crowns and pulp cavities at the cervical line from 4,034 first and second upper molars, first and second upper premolars, first and second lower molars and first and second lower premolars on both left and right sides of 400 patients who had been treated in Dental Hospital of Yonsei University College of Dentistry, and regression equations were derived from the values of the ratio. Results: The equation with correlation coefficients the highest among females was as follows: age=$107.96-75.684{\times}{\sharp}17$ TCHI-$53.741{\times}{\sharp}26$ TCVI-$40.664{\times}{\sharp}45$ TCVI-$56.307{\times}{\sharp}46$ TCVI. Randomized anohter Korean female subjects (n=20) are applicated to the new equation. Mean of error of estimate is 10.322 years, standard deviation is 12.852 years. Minimum of error of estimate is 1.018 years, maximum is 21.365 years Conclusions: The error range of age estimation was found to be slightly wider when the existing regression formulae of Drusini were applied to Korean population groups. Also age estimation in females using the ratio of pulp cavity to dental crown measured with the length and width of dental crowns and pulp cavities from maxillomandibular molars was observed to have the highest reliability in the research. However, we consider that advanced equations of regression are needed to apply to both molars and premolars of males and females in the future.

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

  • Nikneshan, Sima;Sharafi, Mohamad;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.191-196
    • /
    • 2013
  • Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{\circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{\circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{\circ}$ upward tilt of the anterior occlusal plane, and at a $10^{\circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{\circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{\circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.

무질저한 SMVQ 기반의 제로-워터마킹 (Zero-Watermarking based on Chaotic Side Match Vector Quantization)

  • 김형도;박찬권
    • 한국콘텐츠학회논문지
    • /
    • 제9권7호
    • /
    • pp.37-44
    • /
    • 2009
  • 디지털 워터마킹은 디지털 콘텐츠에 워터마크를 삽입함으로써 불법적인 복제를 방지하고, 지적재산권 및 저작권을 보호하며, 소유권을 주장할 수 있는 근거를 제시하는 기술이다. 일반적으로 워터마킹 기법에서는 워터마크를 삽입함으로써 데이터 왜곡과 품질 저하가 불가피하다는 단점이 있다. 이를 극복하기 위하여 원래 데이터를 변경하지 않는 제로-워터마킹 기법들이 최근 제시되고 있다. 이 논문에서는 VQ(Vector Quantization) 방식의 블록 효과를 줄이고, 압축 비율과 품질을 향상시킨 SMVQ(Side Match Vector Quantization) 방식에 대한 제로-워터마킹 체계인 CSMVQ(Chaotic SMVQ)를 제안한다. SMVQ 이미지 압축에서는 동일하게 두 이웃 블록의 접면 정보를 이용하기 위하여 좌측 상단에서 우측 하단으로 진행되므로, 임의의 순서로 블록을 선택하여 워터마크를 삽입할 수 없다. CSMVQ에서는 이전 에 부호화된 (1개에서 4개까지의) 이웃 블록들의 접면 정보를 동적으로 고려하여 부호화를 진행하므로, 무질서한 방식으로 워터마크가 삽입되도록 지원할 수 있다. 이 기법을 적용한 이미지의 품질이 SMVQ보다 우수하며, 샤프닝, 메디안 필터링 등을 이용한 공격에도 워터마크가 강인함을 보여준다.

Characteristic X-ray Spectrum Analysis of Micro-Sized SiC

  • Miyoshi, Noriko;Mao, Weiji;Era, Hidenori;Shimozaki, Toshitada;Shinozaki, Nobuya
    • Applied Microscopy
    • /
    • 제46권1호
    • /
    • pp.27-31
    • /
    • 2016
  • It has been investigated what kind of characteristic X-ray in electron probe micro-analyzer (EPMA) is effective for the determination of compounds of Si series materials. After comparing the characteristic X-rays among the primary and secondary lines in $K_{\alpha}$ and $K_{\beta}$ obtained from the Si series standard samples, it was found that the secondary line of $K_{\alpha}$ exhibited the most informative spectrum although the intensity was considerably weak. As a result of analyzing the spectrum shapes of the Si series standard samples, the spectrum shape of the secondary line of $K_{\alpha}$ for SiC was different from those for other Si compounds. To grasp the characteristics of the shape, a line was perpendicularly drawn from the peak top to base line in order to divide a spectrum into two areas. The area ratio of right to left was defined to call as the asymmetry index here. As a result, the asymmetry index value of the SiC was greater than one, while those of other Si compounds were less than one. It was found from the EPMA analysis that identification of SiC became successful to distinguish from other Si compounds and this method was applicable for micro-sized compounds in a practical composite material.

비스무스 차폐체의 유방 차폐율 분석 (Analysis of breast shielding rate of bismuth shield)

  • 김재석
    • 한국정보통신학회논문지
    • /
    • 제24권9호
    • /
    • pp.1132-1137
    • /
    • 2020
  • 유방 X선 촬영 장치를 이용한 유방 촬영을 실시할 때 발생되는 불필요한 피폭 선량을 경감시키기 위해 비스무스로 제작한 차폐체를 촬영 부위의 반대 측 유방에 적용했을 때 차폐율 분석을 실시하였다. 오른쪽, 왼쪽을 압박하였을 때 CC와 MLO 검사 시 압박되지 않는 유방의 산란 선량을 알아보기 위하여 비스무스를 차폐하지 않았을 때(Not used : NU그룹)와 차폐했을 때(Used : U그룹)로 구분하여 실험을 진행하였다. NU 그룹의 평균선량은 9.568μSv이었고, U그룹의 평균 선량은 1.038μSv이었다. 비스무스 차폐체 사용 전후의 평균 측정 선량은 89.15% 감소되었다. 유방 촬영용 비스무스 차폐체를 사용하면 산란 방사선을 차폐하여 방사선에 의한 노출을 최소한으로 유지할 수 있다.

Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs

  • Dalhae, Kim;Won-Gyun, Son;Donghwi, Shin;Jiyoung, Kim;Inhyung, Lee
    • Journal of Veterinary Science
    • /
    • 제23권6호
    • /
    • pp.68.1-68.8
    • /
    • 2022
  • Background: Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. Objectives: This study evaluated the influence of RR on PPV in mechanically ventilated healthy dogs after hemorrhage. Methods: Five healthy adult Beagle dogs were premedicated with intravenous (IV) acepromazine (0.01 mg/kg). Anesthesia was induced with alfaxalone (3 mg/kg IV) and maintained with isoflurane in 100% oxygen. The right dorsal pedal artery was cannulated with a 22-gauge catheter for blood removal, and the left dorsal pedal artery was cannulated and connected to a transducer system for arterial blood pressure monitoring. The PPV was automatically calculated using a multi-parameter monitor and recorded. Hemorrhage was induced by withdrawing 30% of blood (24 mL/kg) over 30 min. Mechanical ventilation was provided with a tidal volume of 10 mL/kg and a 1:2 inspiration-to-expiration ratio at an initial RR of 15 breaths/min (baseline). Thereafter, RR was changed to 20, 30, and 40 breaths/min according to the casting lots, and the PPV was recorded at each RR. After data collection, the blood was transfused at a rate of 10 mL/kg/h, and the PPV was recorded at the baseline ventilator setting. Results: The data of PPV were analyzed using the Friedman test followed by the Wilcoxon signed-rank test (p < 0.05). Hemorrhage significantly increased PPV from 11% to 25% at 15 breaths/min. An increase in RR significantly decreased PPV from 25 (baseline) to 17%, 10%, and 10% at 20, 30, and 40 breaths/min, respectively (all p < 0.05). Conclusions: The PPV is a dynamic parameter that can predict a dog's hemorrhagic condition, but PPV can be decreased in dogs under high RR. Therefore, careful interpretation may be required when using the PPV parameter particularly in the dogs with hyperventilation.

호흡기계 환자에 대한 양도락 ${\cdot}$ 맥진검사의 진단적 가치 (The Diagnostic Values of Ryodoraku and Pulse Analysis for Respiratory Disease Patients)

  • 황준호;정승연;정승기
    • 대한한방내과학회지
    • /
    • 제28권3호
    • /
    • pp.560-569
    • /
    • 2007
  • Objectives : Ryodoraku is a physiological function test using electric current, and is closely related to skin sympathetic tone. Pulse analysis is known to reflect cardiovascular reactivity. There has been no report on the correlation between ryodoraku and pulse analysis in respiratory diseases. The present study examined the diagnostic values of ryodoraku and pulse analysis for respiratory disease patients Methods : For this study, we conducted ryodoraku and pulse analysis in 103 people including 79 respiratory disease outpatients who visited the $5^{th}$ Internal Department of the Oriental Medicine Hospital of Kyung Hee University during the period from January 1, 2003 to July 25, 2006, and 24 volunteers who did not have any respiratory symptoms or disease history. The respiratory disease patients were divided into five sub-groups according to their symptom: cough-sputum group, wheezing-dyspnea group ' nasal symptoms group. cold-prone group, and fatigue prone group. We compared the disease groups with the control group in six items as follows : mean ryodoraku, mean H1, mean elastic index, the percentage of those with mean ryodoraku below $40{\mu}A$, the percentage of those with HI beyond the physiological range, and the ratio of left : right of elastic index Results and Conclusions : Ryodoraku and pulse analysis were found to have a high value as quantitative diagnosis tools reflecting individuals' weakness and firmness. The results of this research suggest that ryodoraku and pulse analysis have value as tools for diagnosing respiratory diseases.

  • PDF