• 제목/요약/키워드: Left hand

검색결과 762건 처리시간 0.027초

Fully Automatic Coronary Calcium Score Software Empowered by Artificial Intelligence Technology: Validation Study Using Three CT Cohorts

  • June-Goo Lee;HeeSoo Kim;Heejun Kang;Hyun Jung Koo;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1764-1776
    • /
    • 2021
  • Objective: This study aimed to validate a deep learning-based fully automatic calcium scoring (coronary artery calcium [CAC]_auto) system using previously published cardiac computed tomography (CT) cohort data with the manually segmented coronary calcium scoring (CAC_hand) system as the reference standard. Materials and Methods: We developed the CAC_auto system using 100 co-registered, non-enhanced and contrast-enhanced CT scans. For the validation of the CAC_auto system, three previously published CT cohorts (n = 2985) were chosen to represent different clinical scenarios (i.e., 2647 asymptomatic, 220 symptomatic, 118 valve disease) and four CT models. The performance of the CAC_auto system in detecting coronary calcium was determined. The reliability of the system in measuring the Agatston score as compared with CAC_hand was also evaluated per vessel and per patient using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The agreement between CAC_auto and CAC_hand based on the cardiovascular risk stratification categories (Agatston score: 0, 1-10, 11-100, 101-400, > 400) was evaluated. Results: In 2985 patients, 6218 coronary calcium lesions were identified using CAC_hand. The per-lesion sensitivity and false-positive rate of the CAC_auto system in detecting coronary calcium were 93.3% (5800 of 6218) and 0.11 false-positive lesions per patient, respectively. The CAC_auto system, in measuring the Agatston score, yielded ICCs of 0.99 for all the vessels (left main 0.91, left anterior descending 0.99, left circumflex 0.96, right coronary 0.99). The limits of agreement between CAC_auto and CAC_hand were 1.6 ± 52.2. The linearly weighted kappa value for the Agatston score categorization was 0.94. The main causes of false-positive results were image noise (29.1%, 97/333 lesions), aortic wall calcification (25.5%, 85/333 lesions), and pericardial calcification (24.3%, 81/333 lesions). Conclusion: The atlas-based CAC_auto empowered by deep learning provided accurate calcium score measurement as compared with manual method and risk category classification, which could potentially streamline CAC imaging workflows.

임피던스 혈량측정법을 이용한 손가락 혈류량의 측정 (Development of Impedance Plethysmography and Measurement of Digital blood Flow)

  • 김덕원;송철규;김원기;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 춘계학술대회
    • /
    • pp.71-73
    • /
    • 1991
  • In this study electrical impedance plethysmograph was developed and each ten digital blood flow was measured for eight normal males and a patint with digital arterial reconstruction surgery. Blood flow of the digit with surgery was approximately fourty percent compared to that of the other normal digit. For the normal subjects, right-handed subjects generally have larger blood flow in right fingers than that in left fingers while it was reverse for the left-handed subjects. The relative average magnitude of the digital blood flow is the third, first, second, fourth, and fifth digit in descending order for the left and right hand, respectively. Blood flow of the fifth digit for all subjects except one was the smallest among the five digits.

  • PDF

Pulmonary Vein Wedge Angiography 의 임상적 이용 (Clinical Application of Pulmonary Vein Wedge Angiography)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.544-547
    • /
    • 1987
  • Pulmonary vein wedge angiography was applied to two patients of 2 years old TOF with PFO. Left pulmonary artery was not visualized by standard right ventriculogram and catheter was not entered into main pulmonary artery. Through PFO and left atrium, pulmonary vein wedge angiography at left lower pulmonary vein was done. The ipsilateral pulmonary artery & its trees in both cases and the contralateral pulmonary artery in one case were well visualized. Dangerous complication, such as massive bronchoconstriction due to extravasation of contrast material into the bronchus, was not developed. Mild coughing was occurred, but well tolerable in both cases. We recommended a dose of 0.8 mL/Kg of contrast material at a rate of 2 to 3 mL/sec and 1 to 2 mL/Kg of flush solution at the same rate by the hand, and routine use of pulmonary vein wedge angiography in cyanotic patients whose pulmonary artery was not visualized by the standard angiography.

  • PDF

임피던스 혈류량측정기의 개발 및 손가락 혈류량의 측정 (Development of Impedance Plethysmograph and Measurement of Digital Blood Flow)

  • 김덕원;송철규
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권1호
    • /
    • pp.23-28
    • /
    • 1991
  • In this study electrical impedance plethysmograph was developed and each ten digital blood flow was measured for eight nomal males and a patient tvith digital arterial reconstruction surgery. Blood flow of the digit with surgery was approximately fourty percent compared to that of the other normal digit. For the normal subjects, right - handed subjects generally have larger blood flow in right fingers than that in left fingers while it was reverse for the left - handed subjects. The relative average magnitude of the digltal blood flow Is the third, first, second, fourth, and fifth digit in descending order for the left and rich hand, respectively. Blood flow of the fifth digit for all subjec!s except one was the smallest among the five digits.

  • PDF

폐쇄성 혈관 질환의 치료를 위한 Bier Block중에 발생한 Prostaglandin E1의 혈관의 유출 (Extravasation of Prostaglandin E1 during Bier Block for the Treatment of Occlusive Arterial Disease)

  • 최훈;이용태;김동찬;한영진
    • The Korean Journal of Pain
    • /
    • 제7권2호
    • /
    • pp.299-302
    • /
    • 1994
  • Prostaglandin E1(PGE1) is a potent vasodilator and is a useful drug for the treatment of occlusive peripheral vascular disease. It has been used systemically via intravenous route or regionally via intraarterial route. We tried intravenous regional administration of PGE1 for the treatment of a patient with occlusive arterial disease involving left fingers. During the 13th injection, the patient complained of severe pain at the injection site during the drug administration. Thereafter, the patient developed painful and severe swelling with blebs on his left hand. Systemic antibiotics were given together with stellate ganglion block of the affected left side. PGE1 was substituted to reserpine, which is subcutaneously injectable, for the second term treatment.

  • PDF

비신호교차로에서의 교통류특성 및 접근지체모형 개발 -상충지역 통행속도 이용- (Traffic Flow Characteristics and Approach Delay Models of Unsignalized Intersections Based on the Travel Speed)

  • 박용진
    • 대한교통학회지
    • /
    • 제12권2호
    • /
    • pp.47-63
    • /
    • 1994
  • The purposes of this study are to identify Traffic Flow characteristics and to develop approach delay model of unsignalized intersection based on the travel speed in the conflicting area. The results of this study are as following ; 1. The cumulative frequency distributions of Left-turning speed show a few differences among approaches and they are distributed to lower range of speeds. On the other hand, those of through speed show obvious differences among bounds. The similar results also show in the analysis of Percentile speed. 2. The effectiveness of conflicting movements to travel speed in the conflicting area are analyzed using regression analysis. Left-turning speed model shows that Left-and Right-Conflicting speed. Through-speed model is also developed, when approaching through volume is less than 420vph. 3. Since the lost time due to the acceleration stop, and decelerlation is occured in the conflicting area, approach delay model is delivered using the travel speed models under the condition of small queuing delay.

  • PDF

경추 굴곡근과 신전근 및 외측굴곡근의 등척성 근력평가 (Isometric Evaluation of the Flexors, Extensors and Lateral Flexors of the Cervical)

  • 정낙수;최규환
    • 대한물리치료과학회지
    • /
    • 제1권2호
    • /
    • pp.215-222
    • /
    • 1994
  • The aim of this study was to determine the normative strength value for cervical flexors, extensors and right lateral flexors, left lateral flexors to provide a guideline for rehabilitation of cervical radiculopathy patients. The isometric evaluation of cervical flexors, extensors and lateral flexors by using the Hand-held dynamometer was performed on 50 males and 50 females. The result were as follows. The average cervical muscle strength were 5.7 kg in flexor. 10.5 kg in extensors, and 6.6 kg in right lateral flexor, 6.5 kg in left lateral flexor. There was statistically significant difference between the cervical flexors and extensors(p<0.01) but no significant difference between right lateral flexor and left lateral flexor. There was statistically significant difference between male and female(p<0.01). When one of cervical muscle was strong, also the others did in subjects(p<0.01) and the body weight was significantly releated to the cervical muscle strength(p<0.01).

  • PDF

국소한냉자극이 전신 및 국소혈액순환에 미치는 영향 -제 2 보 : 동계 및 하계의 계절변화에 따른 한냉반응- (Cold Pressor Response to Seasonal Variation in Winter and Summer)

  • 박원균;채의업
    • The Korean Journal of Physiology
    • /
    • 제17권2호
    • /
    • pp.93-101
    • /
    • 1983
  • 국소한냉자극이 전신 및 국소혈액순환에 미치는 영향과 동계에 있어서 한냉에 대한 적응을 관찰하기 위하여 동계 및 하계에 편균연령 21세의 남녀 대학생 각 60명 및 50명을 대상으로 $5^{\circ}C$의 냉수에 일측 손을 담구어 3분간 국소한냉자극을 가하였다. 침수 1, 2, 3분과 회복기 1, 3, 5분에 침수한 측과 침수 반대측에서 평균혈압, 분시심박수, 광전 모세혈관 맥박의 파고, 피부전기저항을 관찰하여 다음과 같은 결과를 얻었다. 국소한냉자극시 혈압은 증가하였고 하계에서 동계보다 더 큰 증가를 보였다. 회복기에 동계는 서서히 대조치로 회복되나 하계에는 대조치보다 유의하게 감소하였다. 분시심박수는 침수시 증가하며 하계에서 동계보다 더 증가하였고 회복기에는 동계 및 하계 모두 대조치보다 감소하였다. 광전 모세혈관 맥박의 파고는 동계에는 침수 및 침수 반대측 모두 감소하였으나 침수한 측에서 더 크게 감소하였으며 이는 침수한 측에 있어서 한냉의 국소효과에 기인한 것으로 보인다. 하계에는 동계보다 작은 감소를 보였으며 회복기에는 더 빠른 회복을 보여 대조치보다 증가하였다. 피부전기저항은 침수시 침수 반대측에서는 감소하나 침수한 측에서는 유의하게 증가하였다가 회복기에 서서히 감소하였다. 침수 반대측의 감소는 동통에 의한 반응이 한냉에 의한 반응에 첨가되어 나타난 것으로 보이며, 침수한 측은 한냉에 의한 국소효과가 크기 때문인 것으로 보인다. 이상으로 $5^{\circ}C$의 국소한냉자극시 전신적 반응은 한냉자극에 의한 동통성 stress에 기인한 반응이 우세한 것으로 생각되며 김 등$^{39)}$의 보고와는 달리 동계 및 하계의 반응의 차이는 계절에 따른 한냉자극에 대한 주관적 감각의 차이에 의한 것으로 동계에서 한냉기후에 의한 국소한냉자극의 적응현상은 나타나지 않는 것으로 사료된다.

  • PDF

광주·전남지역 치과위생사의 수근관증후근에 대한 연구 (The study on the Carpal Tunnel Syndrome by dental hygienists at Gwangju·Jeonnam Area)

  • 심형순
    • 한국치위생학회지
    • /
    • 제4권2호
    • /
    • pp.225-236
    • /
    • 2004
  • It has been suggested in research results thai dental hygienists have high risk of carpal tunnel syndrome, mainly caused by the repeated motion of extensor and flexor or the use of vibration tools, compared to other occupations. To find out the situation of the carpal tunnel syndrome of dental hygienists, who are exposed to work-related musculoskeletal disorders, this study used 132 questionnaires given on May 22, 2004, the period of continuing education of the first half year in the Gwangju Jeonnam area, and obtained the following results. 1. Subjects worked at a dental ciinic(32.6%), a hospital(31.8%), and a public health center(35.6%). Age by work was under 24 in a clinic(17.4%) and a hospital(15.9%), and over 30 in a public health center(35.6%). 2. In practice conducted over one time a day, a scaling accounted for 90.7% in a doctor's office; 595% in a hospital; and 3.0% in a public health center, suggesting significant difference(p<0.01). Pit and fissure sealant accounted for 53.5% in a clinic; 53.2% in a hospital; and 95% in a public health center, also suggesting significant difference(p0.01). 3. Symptoms of carpal tunnel syndrome appeared in a wrist(12.1%), a right hand(14.4%), and a left hand(5.3%). 4. In case of temporary crown practice, symptoms appeared in a wrist(22.0%), a right hand(14.0%), and a left hand(4.0%), suggesting significant difference(p<0.01). The above results showed that 12.1% of dental hygienists was exposed to carpal tunnel syndrome. Thus, it is considered very important that dental hygienists should be given education of the danger of continuous work in certain motions and prevention education of improving repeated position, and make efforts to reinforce self-control ability.

  • PDF

정상인의 12경맥 측정전위에 대한 유의성 분석 - 고전경락이론의 수족 . 음양 . 장부의 표리와 오행 . 육기의 표리와 오행을 중심으로 - (Significance Test for Electric Potential of Meridian System - Between hand and foot meridian, yin and yang meridian, exterior and interior of the body, and among the five elements -)

  • 최환수;남봉현
    • 한국한의학연구원논문집
    • /
    • 제6권1호
    • /
    • pp.69-80
    • /
    • 2000
  • Objectives : Assuming that the characteristic of meridian system has been similar to this of electric potentials in human body and that measurements of electric potential at well(井穴) and sea(合穴) points in branches of the twelves meridians will be representative of measurements of the twelve meridians, to measure the electric potentials in twenty healthy volunteers when they were sleeping or waking respectively, to do significance test for electric potential of meridian system between hand and foot meridian, yin and yang meridian, exterior and interior of the body, and among the five elements. Methods : When twenty healthy volunteers were sleeping, their electric potentials of well and sea points in branches of the twelve meridians were simultaneously measured by physiograph. After a minute we measured them again, totally 5 times. And then when they were waking, their electric potentials were measured 5 times by the above method. Results : Measurements were analyzed by statistical t-test, we obtained that the left side electric potential of hand or yin meridian was significantly different from that of foot or yang meridian both sleeping and waking. The right side of electric potential was the same result as the left side's. Most of the t-test was significant between exterior and interior of the body, and among the five elements. That meaned that it was partly possible to apply the ancient theory of meridians to the study of electric potential at well and sea points in branches of the twelves meridians.

  • PDF