• Title/Summary/Keyword: Left Ventricle Ejection Fraction

Search Result 65, Processing Time 0.073 seconds

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

Clinical Experience of Medtronic-Hall Valve (Medtronic-Hall 기계판막의 임상경험)

  • 김종원;정성운
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1031-1036
    • /
    • 1998
  • Background: Medtronic-Hall mechanical valve is a world widely using prosthesis. But, in Korea, the clinical result from Medtronic-Hall valve replacement is not frequenthy available. Materials and methods: From March 1986 to May 1990, 50 patients underwent valve replacement surgery with Medtronic-Hall valve at Pusan National University Hospital. Seventeen were male and thirty three were female and ra nging in age from 16 to 70 years of age(mean=35 years). Results: The causes of valvular lesion were rheumatic in 43 patients, bicuspid aortic valve in 3 patients, degenerative lesion in three patients and bacterial endocarditis in one patient. The operative procedures were mitral valve replacement(MVR) in 38, aortic valve replacement(AVR) in 5 and double valve replacement(DVR) in 7. The most commonly used valve size was 21mm in AVR, 29mm in MVR. Concomitant surgical procedures were performed in 15 patients; left atrial thrombectomy in 9, left atrial auricle obliteration in 6 and tricuspid annuloplasty in 5(Kay: 2, DeVega: 3). New York Heart Association functional class was mostly Class Ⅲ or Ⅳ(91.5%) preoperatively and ClassⅠor Ⅱ(87.2%) after operation. The findings of postoperative echocardiogram of LAD, LVESD, LVEDD were reduced compared with preoperative period and ejection fraction was increased compared with preoperative period. Postoperative complications were massive bleeding in three, low cardiac output syndrome in two, thromboembolism in one and fulminant hepatitis in one patient. There were three hospital deaths and their causes were low cardiac output syndrome in two and rupture of left ventricle in one patient. The 5 year survival rate was 93.65±0.71% and 10 year actuarial survival rate was 88.27±6.42%. Conclusions: Medtronic-Hall mechanical valve has low valve related complication rate. It's durability and hemodynamic performance is comparable to other mechanical valves.

  • PDF

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods (자동화 방식 모델 기반 좌심방 파라미터 측정법: 수동 및 반자동 방식과의 비교)

  • Chae, Seung Hoon;Lee, Whal;Park, Eun-Ah;Chung, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.200-206
    • /
    • 2013
  • Purpose : To assess the effect of applying an automated heart model based measurements of left ventricle (LV) and compare with manual and semi-automated measurements at Cardiovascular MR Imaging. Materials and Methods: Sixty-two patients who underwent cardiac 1.5T MR imaging were included. Steady state free precession cine images of 20 phases per cardiac cycle were obtained in short axis views and both 2-chamber and 4-chamber views. Epicardial and endocardial contours were drawn in manual, automated, and semi-automated ways. Based on these acquired contour sets, the end-diastolic (ED) and end-systolic (ES) volumes, ejection fraction (EF), systolic volume (SV) and LV mass were calculated and compared. Results: In EDV and ESV, the differences among three measurement methods were not statistically significant (P = .399 and .145, respectively). However, in EF, SV, and LV mass, the differences were statistically significant (P=.001, <001, <001, respectively) and the measured value from automated method tend to be consistently higher than the values from other two methods. Conclusion: An automatic heart model-based method grossly overestimate EF, SV and LV mass compared with manual or semi-automated methods. Even though the method saves a considerable amount of efforts, further manual adjustment should be considered in critical clinical cases.

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.

Studies for B-type Natriuretic Peptide Values and Its Association with Diastolic Echocardiographic Parameters (B-type Natriuretic Peptide 수치와 이완기 심초음파 파라미터와의 연관성 연구)

  • Bae, Seong-Jo;Kwon, Kisang;Lee, Eun Ryeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.394-400
    • /
    • 2016
  • The b-type natriuretic peptide (BNP) values and increase on functional disorder in the ventricle, and are used as an index to diagnose heart failure and predict the prognosis. BNP values is known to be relevant to dyssystole in congestive heart failure. This study aimed to identify correlation between the BNP values and the items that indicate the diastolic function in echocardiography. The research divided 188 patients who went through the BNP test and echocardiography in the hospital into the groups with the BNP values; <100, 100-300, 301-600, 601-900, and >901 pg/mL. As the BNP values increase, there was relevance with the echocardiography items of ejection fraction, size of left atrium, E velocity, A velocity, Deceleration time, E/A ratio, E', A', S' and E/E'. In comparison on the groups divided based on the BNP values, E/E' had the highest relevance. The research also categorized 67 patients who diagnosed with heart failure. In comparison on the groups of the heart failure patients, the BNP values of the three groups of Grade I: $623.0{\pm}459.7pg/mL$, Grade II: $1013.2{\pm}1155.1pg/mL$ and Grade III: $1693.4{\pm}1544.0pg/mL$, respectively (p<0.01). As the grade was higher, there was a higher relevance with the echocardiography items of ejection fraction, size of left atrium, E velocity, A velocity, Deceleration time, E/A ratio, E', A', S' and E/E' (p<0.001). Higher BNP values had a higher relevance with the items that indicate the diastolic function in echocardiography and the BNP values of the Restrictive physiology group were the highest in echocardiography. So the BNP values was thought to be valuable to predict diastolic function of heart.

Endoventricular Circular Patch Plasty (Dor Procedure) for Ischemic Left Ventricular Dysfunction (허혈성 좌심실 부전증에서의 좌심실내 원형 패취성형술)

  • Cho, Kwang-Ree;Lim, Cheong;Choi, Jae-Sung;Hong, Jang-Mee;Kim, Hyeong-Ryul;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.755-761
    • /
    • 2004
  • We evaluated the efficacy of Dor procedure in patients with ischemic left ventricular dysfunction. Material and Method: Between April 1998 and December 2002, 45 patients underwent the Dor procedure con-comitant with coronary artery bypass grafting (CABG). Left ventricular ejection fraction (LVEF) and left ventricular end-diastolic/end-systolic volumes (LVEDV/LVESV) were measured by echocardiography, myocardial SPECT, and cardiac catheterization and angiography performed at the sequence of preoperative, early postoperative, and one year postoperative stage. Result: Cardiopulmonary bypass and aortic clamp times were mean 141$\pm$64, 69$\pm$24 minutes, respectively. Intraaortic balloon pump (IABP) therapy was required in 19 patients (42%; 7 preoperatively, 9 intraoperatively, 3 postoperatively). Operative mortality rate was 2.2% (1/45). Postoperative morbidities were low cardiac output syndrome (12), atrial fibrillation (5), acute renal failure (4), and postoperative bleeding (4). Functional class (NYHA) was improved from classes 2.8 to 1.1 (p < 0,01). When we compared between the preoperative and early postoperative values, LVEF was improved from 32$\pm$9% to 52$\pm$11% (p<0.01). The asynergy portion decreased from 57$\pm$12% to 22$\pm$9%, and LVEDV/LVESV indexes improved from 125$\pm$39 mL/$m^2$, 85$\pm$30 mL/$m^2$ to 66$\pm$23 mL/$m^2$, 32$\pm$16 mL/$m^2$ (p<0.01). Although these changes in volumes were relatively preserved at postoperative one year, the left ventricular volumes showed a tendency to increase. Conclusion: After the Dor procedure for ischemic left ventricular dysfunction, LVEF improvement and left ventricular volume reduction were maintained till postoperative one year. The tendency for left ventricular volume to increase at postoperative one year suggested the requirement of strict medical management.

Phase Image Analysis in Conduction Disturbance Patients (심실내 전도장애 환자에서의 $^{99m}Tc$-RBC Gated Blood-Pool Scintigraphy을 통한 Phase Image Analysis)

  • Kwak, Byeng-Su;Choi, Si-Wan;Kang, Seung-Sik;Park, Ki-Nam;Lee, Kang-Wook;Jeon, Eun-Seok;Park, Chong-Hun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.44-51
    • /
    • 1994
  • It is known that the normal His-Purkinje system provides for nearly synchronous activation of right (RV) and left (LV) ventricles. When His-Purkinje conduction is abnormal, the resulting sequence of ventricular contraction must be correspondingly abnormal. These abnormal mechanical consequences were difficult to demonstrate because of the complexity and the rapidity of it's events. To determine the relationship of the phase changes and the abnormalities of ventricular conduction, we performed phase image analysis of $^{99m}Tc$-RBC gated blood pool scintigrams in patients with intraventricular conduction disturbances (24 complete left bundle branch block (C-LBBB), 15 complete right bundle branch block (C-RBBB), 13 Wolff-Parkinson-White syndrome (WPW), 10 controls). The results were as follows; 1) The ejection fraction (EF), peak ejection rate (PER), and peak filling rate (PFR) of LV in gated blood pool scintigraphy (GBPS) were significantly lower in patients with C-LBBB than in controls ($44.4{\pm}13.9%$ vs $69.9{\pm}4.2%,\;2.48{\pm}0.98$ vs $3.51{\pm}0.62,\;1.76{\pm}0.71$ vs $3.38{\pm}0.92$, respectively, p<0.05). 2) In the phase angle analysis of LV, Standard deviation (SD), width of half maximum of phase angle (FWHM), and range of phase angle were significantly increased in patients with C-LBBB than in controls ($20.6{\pm}18.1$ vs $8.6{\pm}1.8,\;22.5{\pm}9.2$ vs $16.0{\pm}3.9,\;95.7{\pm}31.7$ vs $51.3{\pm}5.4$, respectively, p<0.05). 3) There was no significant difference in EF, PER, PFR between patients with the Wolff-parkinson-White syndrome and controls. 4) Standard deviation and range of phase angle were significantly higher in patients with WPW syndrome than in controls ($10.6{\pm}2.6$ vs $8.6{\pm}1.8$, p<0.05, $69.8{\pm}11.7$ vs $51.3{\pm}5.4$, p<0.001, respectively), however, there was no difference between the two groups in full width of half maximum. 5) Phase image analysis revealed relatively uniform phase across the both ventricles in patients with normal conduction, but markedly delayed phase in the left ventricle of patients with LBBB. 6) In 13 cases of WPW syndrome, the site of preexcitation could be localized in 10 cases (77%) by phase image analysis. Therefore, it can be concluded that phase image analysis can provide an accurate noninvasive method to detect the mechanical consequences of a wide variety of abnormal electrical activation in ventricles.

  • PDF

Midterm Results of the Bioprosthesis in Mitral Position (조직판막을 이용한 승모판 치환술의 중기 성적)

  • Cho, Hyun-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.695-702
    • /
    • 2008
  • Background: The choice between a bioprosthetic and a mechanical valve is an important decision in cardiac valve surgery, and the durability of the tissue valve is a major decision factor. We retrospectively evaluated the midterm results of bioprosthetic valve replacement in the mitral position. Material and Method: The subjects were all patients who had undergone mitral bioprosthesis replacement between July 1989 and August 200.7. Among the 216 patients, there were 236 surgical cases. The mean age was $63{\pm}15$ years, and the male to female ratio was 1 : 3. We retrospectively analyzed hospital and outpatient records such that the total follow-up duration amounted to 760.2 patient-years, and the mean follow-up duration was $41.9{\pm}40.7$ months (range $0{\sim}212$ months). Result: Early death occurred in 18 patients (8.3%), and 13 of these underwent concomitant cardiac procedures. The survival rate after 5 years was $79.9{\pm}3.5%$, and the survival rate after 8 years was $65.5{\pm}5.5%$, while freedom from structural valve deterioration (SVD) was $96.2{\pm}2.2%$ at 5 years and $85.9{\pm}5.3%$ at 8 years. Freedom from reoperation was $90.6{\pm}1.7%$ at 5 years and $90.4{\pm}4.2%$ at 8 years, while freedom from reoperation for SVD was $98.1{\pm}1.2%$ at 5 years and $92.3{\pm}4.1%$ at 8 years. On multivariate analysis of preoperative risk factors, small valve size (between 25mm and 27mm) was a significant risk factor for reoperation, and low LV ejection fraction (<40%) was a significant risk factor for SVD and mortality. Conclusion: Survival and freedom from reoperation for SVD in mitral bioprosthesis replacement had acceptable midterm results, but freedom from SVD Was relatively low. In particular, since SVD increased sharply at the eighth postoperative year, frequent follow-up and echocardiograms around that time will be helpful for the early detection of SVD. It will be necessary to conduct further studies involving long-term follow-up and more patients.

Effect of Surgical Closure of Ventricular Septal Defect on Ventricular Systolic Time Intervals (심실중격결손 교정술 전후의 심실 수축기 시간 간격 (Ventricular Systolic Time Interval)의 변화)

  • 이현경;이영환;이장훈;김도형;백종현;이동협;이정철;한승세;정태은
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.511-516
    • /
    • 2002
  • Background: This study was undertaken in infant patients with isolated ventricular septal defect(VSD) to determine the effect of surgical closure on ventricular systolic time interval, as a parameter for ventricular performance, by echocardiography. Material and Method: Thirty patients were enrolled. Mean age of patients at operation was 6.5$\pm$3.2 months and all patients had non-restrictive VSD. We checked the left atrium/aorta(LA/Ao) ratio, left ventricle ejection fraction(EF), left ventricular systolic time interval(LVSTI), and right ventricular systolic time interval(RVSTI). Echocardiographic studies were done before surgical correction and postoperative periods(postopl: within 2 weeks, postop2: between 4 and 6 months, postop3: between 1 and 2 years). Result: LA/Ao ratio decreased significantly at immediate postoperative period compared to preoperative period and sustained during further follow-up period(from 1.74$\pm$0.37 to 1.36$\pm$0.24*, 1.32$\pm$0.22*, and 1.27$\pm$0.19*, p<0.01). LV EF had not changed during follow-up periods(from 65.1$\pm$7.0 to 62.3$\pm$9.5, 62.8$\pm$5.7, and 64.1$\pm$6.9). LVSTI decreased significantly at postop2 and sustained during further follow-up period (from 0.46$\pm$0.13 to 0.46$\pm$0.11, 0.37$\pm$0.08*, and 0.34$\pm$0.07*, p<0.01). RVSTI decreased significantly at postop3(0.33$\pm$0.08 to 0.32$\pm$0.08, 0.31$\pm$0.07, and 0.27$\pm$0.05*, p<0.01). Conclusion: We found that right and left ventricular systolic time intervals had decreased over the period of 1 year after surgical correction of VSD. Therefore, it is necessary to observe the change of ventricular function during that period.