• 제목/요약/키워드: Lee Sang Hyuk

Search Result 1,644, Processing Time 0.031 seconds

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

A Clinical Observation of Children with Urachal Anomalies (요막관 기형의 임상적 고찰)

  • Lee, Sang-Bae;Jung, Chang-Hyun;Kim, Kang-Sung;Ryu, Min-Hyuk;Lee, Dong-Jin
    • Childhood Kidney Diseases
    • /
    • v.9 no.2
    • /
    • pp.213-221
    • /
    • 2005
  • Purpose : Urachal anomalies are rare but are known to develop several complications, especially infection. Moreover, uniform guidelines for management have not been presented because of the variable clinical characteristics of these anomalies. The purpose of this report is to review our experience with urachal anomalies and attempt to determine the optimal management. Methods : We retrospectively reviewed the records of fourteen children with a variety of urachal anomalies who had been treated from January 1996 to June 2005 at Dong Kang General Hospital. Results : The age distribution of the patients(mean age; 3.8 years) was six neonates, one infant, five preschool-age and two school-age children. The male to female ratio was 1:1. Six cases of urachal cyst, four cases of patent urachus, two cases of urachal sinus and two cases of urachal diverticulum were found. Three patients with patent urachus and one with urachal cyst had hydronephrosis. Other associated anomalies included an inguinal hernia in one patient with urachal sinus and a vesicoureteral reflux in one patient with urachal diver ticulum. As a first-line diagnostic tool, high-resolution ultrasound examination was performed in thirteen cases and computed tomography in one case. Surgical excision was performed in nine patients with urachal anomaly. Five cases out of six neonatal cases experienced spontaneous improvement during a three-month follow up period. Due to frequent infection of the umbilicus, surgical excision was performed on one neonate with urachal sinus. Conclusion : All patients with urachal anomalies should undergo investigation for associated anomalies. The neonate with urachal anomalies, especially patent urachus, do not require surgical excision unless the patient has multiple episodes of recurrent infection. (J Korean Soc Pediatr Nephrol 2005;9:213-221)

  • PDF

Characteristics of Low Density Fiberboards Bonded with Different Adhesives for Thermal Insulation (II) - Formaldehyde·Total Volatile Organic Compounds Emission Properties and Combustion Shapes - (다양한 접착제로 제조한 단열재용 저밀도섬유판의 특성(II) - 폼알데하이드·총휘발성유기화합물 방출 특성 및 연소 형상 -)

  • Jang, Jae-Hyuk;Lee, Min;Kang, Eun-Chang;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.580-587
    • /
    • 2017
  • Woodfiber insulation board can be considered as a one of the key material for low energy consumption, comfortable and safety construction of residential space because of its eco-friendly and high thermal insulation performance. This study was carried out to investigate the formaldehyde (HCHO) total volatile organic compounds (TVOC) emission properties and combustion shapes by flame test of low density fiberboards (LDFs) prepared with different adhesives. HCHO TVOC emission and combustion properties of LDFs prepared by melamine urea formaldehyde (MUF), phenol formaldehyde (PF), emulsified methylene diphenyl diisocyanate (eMDI) and latex resin adhesives were measured by desiccator method, 20 L chamber method, and flame test, respectively. As results, LDFs manufactured by MUF, eMDI and latex resin adhesives satisfied the Super $E_0$ grade of HCHO emission performance except PF resin. Furthermore, TVOC emission of all LDFs were satisfied the Korean indoor air quality standard (below $400{\mu}g/m^2{\cdot}h$). Especially, LDF with eMDI resin adhesive showed the lowest HCHO and TVOC emissivity, that $0.14mg/{\ell}$, $12{\mu}g/m^2{\cdot}h$, respectively. However, eMDI emitted the small amount ($3{\mu}g/m^2{\cdot}h$) of toluene in VOC components. In the flame test, LDF with MUF resin adhesives showed the most favorable shape after flame test compare to LDFs prepared other adhesives. Based on HCHO and TVOC emission, and combustion shapes, MUF resin adhesive may be recommended to prepare LDF for insulation purpose.

Effects of Brewers Grain, Soybean Curd and Rice Straw as an Ingredient of TMR on Growth Performance, Serum Parameters and Carcass Characteristics of Hanwoo Steers (섬유질 배합사료 원료로서 맥주박, 비지박 및 볏짚이 한우 거세우의 사양성적, 혈액성상 및 도체특성에 미치는 영향)

  • Chang, Sun Sik;Kwon, Hyuk Jin;Lee, Sang Min;Cho, Young Moo;Chung, Ki Yong;Choi, Nag Jin;Lee, Sung Sill
    • Journal of Animal Science and Technology
    • /
    • v.55 no.1
    • /
    • pp.51-59
    • /
    • 2013
  • This study was conducted to investigate the dietary effect of total mixed rations (TMR) containing brewers grain, soybean curd and rice straw, respectively, on growth performance and carcass characteristics of Hanwoo steers. Twenty four Hanwoo steers (average body weight 168 kg) in 6 months age were randomly allocated to 4 experimental groups, which contained 6 animals per group during 22-months feeding trial. The treatment was composed of the group fed concentrate and rice straw separately (T1), the group fed TMR containing brewers grain (T2), the group fed TMR containing soybean curd (T3) and the group fed TMR containing rice straw (T4). Body weight (BW) was not different among treatment groups during the growing and middle fattening period. However, it was significantly greater in T4 group than in T2 group on the final BW (p<0.05). Average daily gain was significantly greater in TMR groups compared to T1 group on the growing and late fattening (p<0.05). However, it was not different in total average. Dry matter intake tended to be increased in TMR groups. The feed conversion ratio was significantly lower in T4 group compare to T2 group (p<0.05). According to the yield traits, carcass weight of T1, T2, T3 and T4 were 389.0, 368.4, 387.5 and 384.3 kg, respectively. The back fat thickness, rib-eye area, and yield index were not different among the groups. Meat color, fat color, texture and maturity were not significantly different among groups. However, marbling score and appearance rate of meat quality grade of over $1^+$ were greater in T2 and T3 groups compare to other groups. Therefore, these results indicated that TMR with brewers grain and soybean curd may be ameliorated the growth performance and carcass characteristics of Hanwoo steers.

The Clinicopathologic Characteristics of Patients with Gastric Carcinoid Tumor (위 유암종의 임상병리학적 특징에 대한 후향적 연구)

  • Jang, Jeong-Moon;Kong, Seong-Ho;Yoon, Hong-Man;Ahn, Hye-Seong;Lee, Hyuk-Joon;Yoon, Won-Jae;Kim, Sang-Kyoon;Yang, Han-Kwang;Lee, Kuhn-Uk
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.262-268
    • /
    • 2009
  • Purpose: We wanted to analyze the clinicopathologic characteristics of patients with gastric carcinoid tumor, which is a rare gastric tumor (less than 2% of all gastric tumors). Materials and Methods: We reviewed all the carcinoid patients who were treated from 1996 to 2006. The clinicopathologic characteristics, the treatment modalities and the survival rates were retrospectively analysed. Results: There were 8 type I patients and 10 type III patients, but there were no type II patients. The mean age of onset for type I was 47.75 years and that for type III was 57.90 years. More type III patients were female, but the gender ratio of type I patients was equal at a ratio of 1:1. There were 4 cases of solitary tumor, which were all T1 except for one case, and there was neither distant metastasis nor lymph node involvement for the type T1 cases. In the 13 patients who had no metastasis, 5 underwent endoscopic mucosal resection and 8 underwent surgery, and their combined 5 year survival rate was 92.3%. For the 5 cases who had metastastses, their mean survival was 22 months and especially, 3 of them underwent palliative surgery and their median survival were 24 months (95%, ${\pm}6.52$). Conclusion: Higher incidence of type III gastric carcinoid tumor and less multiplicity in type I gastric tumor were identified in our study compared with previous reports. For the type III cases, there were some noteable differences compared with the Western country's survival rate for the patients who underwent palliative surgery, so physicians must pay close attention to the definite clinicopathologic characteristics of gastric carcinoid patients.

  • PDF

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.

Antioxidant, Antiaging and Antimicrobial Effects of Ethanolic Extract and Ethyl Acetate Fraction from Eclipta prostrata (한련초 에탄올 추출물과 에틸아세테이트 분획물의 항산화, 항노화 및 항균 효과)

  • Lee, Sang Lae;Song, Ba Reum;Shin, Hyuk Soo;Lee, Yun Ju;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.3
    • /
    • pp.349-362
    • /
    • 2018
  • An annual plant, Eclipta prostrata (Linn) is a member of the Asteraceae plant family and inhabited in tropical or subtropical regions of the world. Through many previous researches, E. prostrata has been extensively studied for its hepatoprotective effect, antivenom potential against viper venom, antioxidant, hair-growth, wound-healing efficacy and so on. In this study, for better understanding of the potential of E. prostrata as skin protectant, we conducted the experiments evaluating the antioxidant and antiaging efficacy. To this end, 50% ethanolic extract of E. prostrata and its ethyl acetate fraction were prepared and investigated. For the evaluation of antioxidant capacity of the samples, $FSC_{50}$ and $OSC_{50}$ were estimated. As a result, $OSC_{50}$ of ethyl acetate fraction was 2.7 times superior to $OSC_{50}$ of L-ascorbic acid, a well known antioxidant agent. Futhermore E. prostrata showed notable reactive oxygen species (ROS) scavenging effect and protective effect against $H_2O_2$ in the celluar level as well. Especially, in the $^1O_2$ induced hemolysis test, $64{\mu}g/mL$ of ethyl acetate fraction showed greater than 6 times increased retardation effect compare to control which means E. prostrata has remarkable antioxidant capacity. To validate the antiaging effect of the samples, we conducted elastase inhibition assay using elastase solution extracted from human skin fibroblasts, Hs68. As a result, $16{\mu}g/mL$ of each sample showed 6.8% and 14.0% of elastase inhibition respectively. Finally, antimicrobial activity of E. prostrata was assessed to validate the possibility as alternative preservative. From the result, ethyl acetate fraction showed oustanding antimicrobial activity as of methyl paraben, a well known chemical preservative. In conclusion, these results suggest that E. prostrata can be used as natural skin protectant or preservative as natural ingredient in food or cosmetics industry.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

Correction of Artifacts due to Patient Arm Motion in PET/CT: Scatter-Limit Correction (PET/CT 검사에서 움직임에 의한 인공물의 산란제한보정법 적용 영상 평가)

  • Bahn, Young Kag;Lee, Seung Jae;Kim, Jung Yul;Oh, Sin Hyun;Nam-Koong, Hyuk;Park, Hoon-Hee;Kang, Chun Koo;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.44-48
    • /
    • 2012
  • Purpose : Arm motion can give rise to striking cold artifact on PET/CT. We investigated that evaluation of scatter-limit correction and correct the patient arm motion artifact in Discovery 600 PET/CT. Materials and Methods : To evaluate a radioactivity uptake (Bq/ml) and a standard uptake value (SUV), the scatter limit correction and scatter correction were compared using 1994 NEMA Phantom$^{TM}$ in Discovery 600 PET/CT (GE Healthcare, Mi, We). Arm motion phantom study was involved a central 20 cm diameter cylinder simulating the neck and 2 peripheral 10 cm diameter cylinders simulating arms. The positions of the arms were altered so as to introduce different amounts of misalignment. The evaluation of arm motion phantom study used the radioactivity uptake and SUV in scatter correction and scatter limit correction. Results : The statistical significance of radioactivity uptake and SUV did not show the differences in comparisons of the scatter limit correction and the scatter correction that not show (p<0.05). Radioactivity uptake of the scatter correction was up to 3.1 kBq/ml in the 0.04 kBq/ml. It was approximately 98.7% undervalued in the arm motion phantom study. However, Radioactivity uptake of the scatter limit correction was up to 3.0 kBq/ml in the 2.11 kBq/ml. It was approximately 30% undervalued in arm motion phantom study. SUV of the scatter correction was 1.05 to 0.006 and underestimated about 98%. However, an applying SUV of the scatter limit correction changed the value as 0.67 which is underestimated about 25%. Radioactivity uptake and SUV of the scatter limit correction was increased approximately 60%, or more than the scatter correction. Conclusion : It is considered that if the patient arm motion artifact was occurred the scatter limit correction will be applicable to give an accurate diagnosis.

  • PDF

The immunogenicity and reactogenicity of Td booster vaccination in Korean preadolescents, aged with 11-12 years old (국내 11-12세 소아에서 Td 백신 추가접종의 면역원성과 안전성 평가)

  • Lee, Soo Young;Kwak, Ga Young;Mok, Hye Rin;Kim, Jong Hyun;Hur, Jae Kyun;Lee, Kyung Il;Park, Joon Su;Ma, Sang Hyuk;Kim, Hwang Min;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1185-1190
    • /
    • 2008
  • Purpose : This study was undertaken to evaluate the immunogenicity and reactogenicity of Td booster immunization in early preadolescents of Korea. Methods : Healthy preadolescents, who had been vaccinated with 4 or 5 doses of DTaP vaccines until 6 years old age, were enrolled in this study from August 2006 to April 2007. Diphtheria and tetanus anti-toxoid antibodies in sera were measured by ELISA just before vaccination and 4 weeks after vaccination to evaluate immunogenicity. Local and systemic adverse reactions observed for 4 weeks after vaccination to access reactogenicity. Results : 183 preadolescents were enrolled and mean age was $11.40{\pm}0.51$ years old. All subjects achieved seroprotective diphtheria and tetanus anti-toxoid antibodies (titers ${\geq}0.1IU/mL$) after Td booster vaccination. Among 183 vaccinees, 73.8% showed local adverse reactions and 37.2% systemic adverse reactions. Pain at injection site (66.1%) was the most common local reaction, and the most commonly shown systemic reaction was myalgia (17.5%). The adverse reactions were spontaneously relieved within three days after vaccination. Conclusion : Td vaccine in this study was high immunogenic and showed an acceptable tolerance in Korean preadolescents. Td booster vaccination at 11-12 years old is the most effective method to increase compliance of the vaccination and to decrease the incidence of diphtheria and tetanus.