• Title/Summary/Keyword: Leaks

Search Result 438, Processing Time 0.024 seconds

Industrial Technology Leak Detection System on the Dark Web (다크웹 환경에서 산업기술 유출 탐지 시스템)

  • Young Jae, Kong;Hang Bae, Chang
    • Smart Media Journal
    • /
    • v.11 no.10
    • /
    • pp.46-53
    • /
    • 2022
  • Today, due to the 4th industrial revolution and extensive R&D funding, domestic companies have begun to possess world-class industrial technologies and have grown into important assets. The national government has designated it as a "national core technology" in order to protect companies' critical industrial technologies. Particularly, technology leaks in the shipbuilding, display, and semiconductor industries can result in a significant loss of competitiveness not only at the company level but also at the national level. Every year, there are more insider leaks, ransomware attacks, and attempts to steal industrial technology through industrial spy. The stolen industrial technology is then traded covertly on the dark web. In this paper, we propose a system for detecting industrial technology leaks in the dark web environment. The proposed model first builds a database through dark web crawling using information collected from the OSINT environment. Afterwards, keywords for industrial technology leakage are extracted using the KeyBERT model, and signs of industrial technology leakage in the dark web environment are proposed as quantitative figures. Finally, based on the identified industrial technology leakage sites in the dark web environment, the possibility of secondary leakage is detected through the PageRank algorithm. The proposed method accepted for the collection of 27,317 unique dark web domains and the extraction of 15,028 nuclear energy-related keywords from 100 nuclear power patents. 12 dark web sites identified as a result of detecting secondary leaks based on the highest nuclear leak dark web sites.

Acoustic Emission (AE) Technology-based Leak Detection System Using Macro-fiber Composite (MFC) Sensor (Macro fiber composite (MFC) 센서를 이용한 음향방출 기술 기반 배관 누수 감지 시스템)

  • Jaehyun Park;Si-Maek Lee;Beom-Joo Lee;Seon Ju Kim;Hyeong-Min Yoo
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.429-434
    • /
    • 2023
  • In this study, aimed at improving the existing acoustic emission sensor for real time monitoring, a macro-fiber composite (MFC) transducer was employed as the acoustic emission sensor in the gas leak detection system. Prior to implementation, structural analysis was conducted to optimize the MFC's design. Consequently, the flexibility of the MFC facilitated excellent adherence to curved pipes, enabling the reception of acoustic emission (AE) signals without complications. Analysis of AE signals revealed substantial variations in parameter values for both high-pressure and low-pressure leaks. Notably, in the parameters of the Fast Fourier Transform (FFT) graph, the change amounted to 120% to 626% for high-pressure leaks compared to the case without leaks, and approximately 9% to 22% for low-pressure leaks. Furthermore, depending on the distance from the leak site, the magnitude of change in parameters tended to decrease as the distance increased. As the results, in the future, not only will it be possible to detect a leak by detecting the amount of parameter change in the future, but it will also be possible to identify the location of the leak from the amount of change.

Cookies (쿠키)

  • Yeon, Jea-Young
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.567-571
    • /
    • 2008
  • As computer technology grows, the risk of personal information leak on the internet is also increasing. A so-called "cookie" is used as one of the ways personal information leaks. A cookie offers convenience on the internet but serves as a major reason for personal information leakage at the same time. In this paper, we discuss risks and potential managements of a cookie.

  • PDF

Treatment of the complications of the esophageal reconstructive procedures (식도 재건 수술후 발생한 합병증 치험)

  • Lee, Du-Yeon;Yun, Chi-Sun;Hong, Seung-Rok
    • Journal of Chest Surgery
    • /
    • v.24 no.5
    • /
    • pp.463-469
    • /
    • 1991
  • Post-anastomotic leakage and stenoses remain major complications and are still responsible for many mortalities after esophageal reconstructive procedures. If the hand-suture is used, anastomotic leaks developed frequently than stenoses. But post-anastomotic leakages are more critical than post-anastomotic stenoses. If the stapler is used, anastomotic stenoses will develop frequently and not critical than anastomotic leakages. The stapler suture method is easier and quicker than the hand suture method in the esophageal anastomotic procedures. But the disadvantages of the stapler suture method is that there is not reachable site with anastomotic stapler the thoracic inlet region and the cost is expensive. We have treated 44 cases of the surgical complications after esophageal reconstructive procedure with conservative and surgical treatment for 10 years from January, 1980 to December, 1989. The anastomotic site stenoses were 8 cases in the hand-suture methods and 4 cases in the stapler-suture methods. The anastomotic leaks were 8 cases in hand-suture methods and 5 cases in stapler-suture methods. There were one death in the surgical repair of four post-operative anastomotic stenoses and two deaths in the surgical repair of three post-operative anastomotic leakages. Ever though we consider that there is more anastomotic leakage than stenoses after the hand-suture methods in esophageal reconstructive procedures. the cost with long stay in the intensive care unit to treat anastomotic leakage after the hand-suture, would be more expensive than-the cost of the treatment of the anastomotic stenoses after auto-suture.

  • PDF

A Study on The Leak of Core Business Technologies Using Preventative Security Methods Such as Clustering (군집화를 이용한 기업 핵심기술 유출자 분류에 관한 연구)

  • Huh, Seung-Pyo;Lee, Dae-Sung;Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.10 no.3
    • /
    • pp.23-28
    • /
    • 2010
  • Recently, the leak of domestic core technology of major business in Korea and the subsequent damage, has been increasing every year. Financial losses due to this leak are estimated to be about 220 trillion, which is equivalent to the gross budget of Korea Besides, the majority of the leaks are caused by former and current staff members, cooperated businesses, scientists and invesment companies. This shows that the source of the leaks are internal personnel. In this manner, we can infer that the management and plan of personnel security has not implemented sound practices to prevent technology leak by people. Therefore, this thesis suggests classifying methods of technology leak through clustering, one of the data mining methods about the information of internal personnel to prevent core technology leak from businesses.

Characteristics of Water Leakage from Cooling Components in a Storage Ring (방사광 차단용 진공부품의 냉각수 누설 특성)

  • Park, C.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • We analyzed the characteristics of water leakage from cooling components of the storage ring in the Pohang Light Source. The water leaks led localized pressure bumps and abnormal pressure changes. The leakage also changed the residual gas compositions depending not only on the position between leakage place to gas analyzer but also on on/off switching of ion pump and electron beam. We found that the residual gas analysis of $CH_4$, CO, NO was useful in determining water leaks.

Nondestructive Testing and Applications for Integrity Assessment of Power Plant Facilities by Acoustic Emission Technology - Part 1 : The Theory of Acoustic Emission Technology(I) - (발전설비 건전성평가를 위한 음향방출 비파괴검사 적용기술 - 제1편 : 음향방출 비파괴검사기술 이론(I) -)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.5-13
    • /
    • 2005
  • Acoustic emission(AE) is defined as the transient elastic waves thar are generated by the rapid release of energy. The advantage of AE is that very early crack growth can be detected well before a highly stressed component may fail. At present, an exact diagnosis is the most reliable means for determining the soundness of structures during power plant operations. AE monitoring has been applied successfully in power plants to determine mechanical problems, pressure vessel integrity and external valves leaks, vacuum leaks, the onset of cavitation in pumps and valves, the presence of flow(or no flow) in piping and heat exchange equipment, etc. Acoustic emission(AE) technology has recently strengthened its application base, and practitioners' understanding of the technique's fundamentals. This paper introduces the methods of a survey and assessment on AE monitoring applications in nuclear, fossil and hydraulic power plant. The main objective of this paper was to obtain information on various applications of AE technology in power plant.

  • PDF

Key Management Server Design for Providing Cryptographic Service in Cloud Computing Environment (Services in a Cloud Environment)

  • Jung, Ki Hyun;Shin, Seung Jung
    • International journal of advanced smart convergence
    • /
    • v.5 no.4
    • /
    • pp.26-31
    • /
    • 2016
  • In a cloud computing environment, a cryptographic service allows an information owner to encrypt the information and send it to a cloud server as well as to receive and decode encrypted data from the server which guarantees the confidentiality of shared information. However, if an attacker gains a coded data and has access to an encryption key via cloud server, then the server will be unable to prevent data leaks by a cloud service provider. In this paper, we proposed a key management server which does not allow an attacker to access to a coded key of the owners and prevents data leaks by a cloud service provider. A key management server provides a service where a server receives a coded public key of an information user from an owner and delivers a coded key to a user. Using a key management server proposed in this paper, we validated that the server can secure the confidentiality of an encryption key of data owners and efficiently distribute keys to data users.

Esophageal Atresia with Tracheoesophageal Fistula : A 20 Year Experience of 51 Cases (식도기관루를 동반한 선천성 식도폐쇄 -20년간 51례 치료경험-)

  • Han, Jae-Hyun;Chung, Jae-Hee;Song, Young-Tack
    • Advances in pediatric surgery
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The aim of this study is to analyze the outcomes of the esophageal atresia with tracheoesophageal fistula over the last 2 decades. The records of 51 patients born between 1987 and 2006 were reviewed. Twenty-seven patients were male. Mean values of the age, gestational age and birth weight were 2.9 days, 296 days and 2.7kg, respectively. All patients had Gross type C anomalies. Thirty-one patients (60.7 %) had one or more associated congenital anomalies and the most common anomaly was cardiac malformation. In 48 cases, primary anastomosis was done and staged operation was done in one case. Circular myotomies in the proximal esophagus were performed in 9 cases. Postoperative complication developed in 26 cases (54 %): pulmonary complication in 12 cases, anastomotic leakage in 10 and anastomotic stricture in 10, recurrent trachoesophageal fistula in one and tracheomalasia in 2 cases. Reoperation was carried out in 2 patients with anastomotic leaks, the remaining leaks were managed non operatively. Three of the strictures were reoperated upon and the others were successfully managed by balloon dilatations. Overall mortality rate was 15.6 %. Mortality rate of the second 10 years (8 %) period decreased significantly compared to that of the first 10 years (23 %) period.

  • PDF

Endoscopic vacuum therapy for treatment of spontaneous and iatrogenic upper gastrointestinal defects

  • Kavea Panneerselvam;Jake S. Jacob;Ronald E. Samuel;Andy Tau;Gyanprakash A. Ketwaroo;Wasif M. Abidi;Robert J. Sealock
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.754-760
    • /
    • 2023
  • Background/Aims: Endoscopic vacuum therapy (EVT) can heal a variety of defects within the gastrointestinal (GI) tract via applying negative pressure, which reduces the defect size, aspirates the infected fluid, and promotes granulation tissue. Here we present our experience with EVT as it relates to both spontaneous and iatrogenic upper GI tract perforations, leaks, and fistulas. Methods: This retrospective study was conducted at four large hospital centers. All patients who underwent EVT between June 2018 and March 2021 were included. Data on multiple variables were collected, including demographics, defect size and location, number and intervals of EVT exchanges, technical success, and hospital length of stay. Student t-test and the chi-squared test were used to analyze the data. Results: Twenty patients underwent EVT. The most common defect cause was spontaneous esophageal perforation (50%). The most common defect location was the distal esophagus (55%). The success rate was 80%. Seven patients were treated with EVT as the primary closure method. The mean number of exchanges was five with a mean interval of 4.3 days between exchanges. The mean length of hospital stay was 55.8 days. Conclusions: EVT is a safe and effective initial management option for esophageal leaks and perforations.