• Title/Summary/Keyword: Leakage water

Search Result 894, Processing Time 0.03 seconds

Analysis of temperature monitoring data for leakage detection of earth dam (흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Seo, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE (LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성)

  • 박영국;강성화;정수현;박철현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Differences of Germination Rate, Degree of Solute Leakage and Water Uptake Rate of Soybean Seeds in Two Storage Periods (저장기간에 따른 콩종실의 발아율이, 용출정도 및 수분흡수율의 차이)

  • 손범영;박금룡;김석동;김수희
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.1
    • /
    • pp.95-102
    • /
    • 1996
  • This investigation was conducted to investigate if germination rate, degree of solute leakage and water uptake rate of seeds are a meaningful information for the selection criteria among soybean genotypes and to find out their characteristics in the variable temperature and moisture conditions encounted during long-term warehouse storage. Germination rate in soybean sprouting box and petri dish differed largely among genotypes stored for twenty months but there was little difference when stored for eight months. Length of hypocotyl was shorter at twenty months of storage than at eight months. Degree of solute leakage of Paldalkong and Pulmuwon was twice higher than that of SS88038 lines at twenty months of storage. In 30 minutes after imbibition, water uptake rate in all genotypes stored for twenty months was faster than these stored for eight months, and water uptake rate in Paldalkong and Pulmuwon stored for eight months was 1.5 and 2 times faster than in SS88038 lines. In correlation coefficients, the germination ability and emergence exhibited significantly negative correlation with degree of solute leakage at twenty months of storage. Water uptake rate in soybean seeds stored for eight months had highly significant positive correlation with degree of solute leakage in 30 minutes and one hour after imbibition while for twenty months of storage, it had highly significant positive correlation with that in 30 minutes, one hour and three hours after imbibition. In eight months of storage, the number of open micropyle had positive correlation with water uptake rate at 30 minutes after imbibiton. But in seeds stored twenty months, it wasn't correlated with water uptake.

  • PDF

Analysis the influence of the exterior insulation deterioration and water leakage on the aging of concrete structure (건축 구조물 외단열 시스템의 열화 및 누수현상이 구조물 노후화에 미치는 영향 분석에 관한 연구 - 초고층 oo 아파트 외벽 누수 사례를 통하여 -)

  • Park, Yeun-Jin;Park, Jin-Sang;Seon, Yun-Suk;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.159-163
    • /
    • 2007
  • We studied the example of various side on effect the aging of exterior materials for concrete structure by analyzing the reason of water leakage in exist serviced skyscraper apartment. For this side, we would like to suggest the proper waterproofing materials and construction methods resulted in the mechanical performance test. So, it could be ensured the leakage safety for using residence facility and crowd utilization after repairing. It may maximize the durability for the concrete structure.

  • PDF

Quality control plan for water leaks through step-by-step review of modular housing (모듈러 주택 단계별 검토를 통한 누수하자 품질관리 방안)

  • Cho, In-Su;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.169-170
    • /
    • 2023
  • Leakage defects account for a significant proportion of defect cases in modular homes. There are factors that can cause leakage defects at each stage, and quality control measures are required to minimize them. An improvement plan to prevent leakage defects was applied from the design drawings to the site of a modular public rental apartment complex in Sejong City 6-3, and a quality control plan was proposed to minimize leakage defects in the remaining process processes.

  • PDF

Reduction Techniques of the Pipe Line net Using According to DVGW (DVGW이론에 따른 상수관망의 부식방지를 위한 정수처리방안)

  • Choo Tai-Ho;Kim Ha-Il
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.115-118
    • /
    • 2005
  • Leakage of waterworks pipe line net cause loss of water resources, additional foundation of pressurization facilities from pressure loss and soil weakening near leaked pipe line, etc. This is difficult to maintain and manage waterworks pipe line net and to cause serious economic loss. Rate of accounted water is better by monitoring always water pressure and flux, etc. from isolated region, positively dealing with leakage accident and preventing leakage from occurring. Actually after isolating region, average rate of accounted water in this region is 88.94% by continuously monitering control of water pressure and inflow rate. It is about 9.44% more than that of Busan metropolitan city in 2003, 79.5%.

  • PDF

Delineation of water seepage in a reservoir embankment from ground temperature measurements (지온탐사에 의한 저수지 제방의 누수 조사)

  • 박삼규
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.169-175
    • /
    • 1999
  • The water leakage of reservoir embankment usually occurs through water vein, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disater prevention and embankment protection. This paper presents survey results of one-meter-depth ground temperature and multi-point temperature logging in an embankment in Japan to delineate water veins and permeable formations. Four water veins have been predicted in the embankment by comparing measured one-meter-depth ground temperatures with the background ones which have no effect of water vein. The multi-point temperature logging was carried out in the borehole drilled at one of the predicted water veins. Depth and thickness of the permeable formation in the borehole can be determined from temperature restoration ratios with elapsed time. From these results we can find that the water leakage of reservoir embankment mainly occurs in sandy soil formation in the embankment.

  • PDF

A Study on Anti-Pollutions Characteristics of RTV Silicone Rubber (RTV 실리콘 고무의 내오손 특성에 관한 연구)

  • Huh, Chang-Su;Lee, Sang-Youb;Youn, Bok-Hee;Hwang, Myung-Kun;Lee, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1651-1653
    • /
    • 1999
  • Room Temperature Vulcanizing (RTV) Silicone Rubber has been widely used to coat porcelain insulator to prevent formation water filming on insulator surface. and RTV silicone rubber has water repellency to suppress leakage current and consequent flashover. RTV silicone rubber's surface has been degradated by outdoor condition such as dust, salt, and water. etc. ESDD(Equivalent Salt Deposit Density) and leakage currents are increased by polymer surface toughness and degradation. In this paper, we investigated relations of surface toughness, ESDD, and leakage currents.

  • PDF