• Title/Summary/Keyword: Leakage signal

Search Result 342, Processing Time 0.022 seconds

The Implementation of Active Leakage Current Detecting Algorithm based on 16 bit Signal Processor (16비트 신호처리 프로세서 기반 유효성분 누설전류 감지 알고리즘 구현)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2016
  • The ELCB(: Earth Leakage Circuit Breaker) is the only way being used to prevent accidents from happening caused by electrical disaster. However, the existing ELCB has a limit to prevent damages to life and property due to a electric fire and a human body electric shock caused by the resistive leakage current, because of detecting the total leakage current in the block range of 15mA~30mA. It also has problems such as reduced productivity and reliability due to malfunctions by capacitive leakage currents. In this study, we have implemented the algorithm for the resistive leakage current detection technique and developed the resistive leakage current detection module based on a MSP430 processor, 16bit signal processor and this module can be operated in a desired block threshold within 0.03 seconds as specified in KS C 4613.

A Study on the Signal Correction for Multiple Defects in MFL Type Nondestructive Testing System (MFL 비파괴 검사 시스템에서 다중 결함에 의한 신호 왜곡과 신호 보정에 관한 연구)

  • Park, Jeng Hoon;Kim, Hui Min;Park, Gwan Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.24-30
    • /
    • 2016
  • MFL (Magnetic flux leakage) type nondestructive testing has been used for inspection of underground gas pipelines to find metal defects by detecting magnetic leakage signal. Because the underground gas pipeline is exposed by environment such as high pressure with great humidity, external defects are easily formed on the surface of pipelines and they are being grouped respectively. These adjacent defects cause the signal distortion of leakage flux so that it is hard to estimate the shape information of defects. In this paper, we performed to study of the signal distortion and compensating method for multiple defects in MFL type nondestructive testing system by using 3D FEM simulation. This paper proposes the basic algorithm of defect signal analysis on multiple defects on the surface of 30 inch diameter pipeline.

Analysis of the Electromagnetic Leakage from Liquid Crystal Display Monitors (LCD 모니터의 누설 전자파에 대한 분석)

  • Lee, Ho seong;Sim, Kyuhong;Oh, Seungsub;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.9
    • /
    • pp.844-853
    • /
    • 2016
  • Generally, the compromising electromagnetic emanations are generated from LCD(Liquid Crystal Display) monitor which is typical output component of computer. Because display information transmitted to LCD monitor is included in these emanations, there are risks about information leakage of monitor by eavesdropping of leaked signal. So, analysis about possibility of information leakage is necessary because electromagnetic security through the electromagnetic emanations is being at issue. In this paper, the possibility of display information leakage are demonstrated by analyzing the electromagnetic emanations from desktop and laptop monitors. The characteristics of leaked signal from LCD monitor is verified by analyzing display mechanism and the electromagnetic emanations are measured in the long distance by eavesdropping experiment. Also, threat of information leakage is confirmed by recovering display information with several signal processing technique and comprising with target display.

Improvement of MFL sensing-based damage detection and quantification for steel bar NDE

  • Kim, Ju-Won;Park, Minsu;Kim, Junkyeong;Park, Seunghee
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.239-247
    • /
    • 2018
  • A magnetic flux leakage (MFL) method was applied to detect and quantify defects in a steel bar. A multi-channel MFL sensor head was fabricated using Hall sensors and magnetization yokes with permanent magnets. The MFL sensor head scanned a damaged specimen with five levels of defects to measure the magnetic flux density. A series of signal processing procedures, including an enveloping process based on the Hilbert transform, was performed to clarify the flux leakage signal. The objective damage detection of the enveloped signals was then analyzed by comparing them to a threshold value. To quantitatively analyze the MFL signal according to the damage level, five kinds of damage indices based on the relationship between the enveloped MFL signal and the threshold value were applied. Using the proposed damage indices and the general damage index for the MFL method, the detected MFL signals were quantified and analyzed relative to the magnitude of the damage increase.

Water Leakage Detection Monitoring Simulation using Power Spectrum Analysis (파워스펙트럼 분석을 이용한 누수탐지 모니터링 시뮬레이션)

  • Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.1
    • /
    • pp.48-54
    • /
    • 2013
  • With the development of IT convergence technology and the construction of infrastructure for water leakage detection, the detection technology of damaged pileline's location and size is being spotlighted. The exhaustion of water resource due to the leakage of water supply facilities renders it urgent to detect water leakage effectively. In this paper, we proposed the water leakage detection monitoring simulation using the power spectrum analysis. We measured the reflected wave signal by the proposed water leakage detection monitoring simulation. The rate variability is calculated form the acquired reflected wave signal. And the power spectrum analysis using the Fast Fourier Transform is evaluated the correlation between the water leakage's size and the reflected wave. Ultimately, this paper suggests empirical simulation to verify the adequacy and the validity. Accordingly, the satisfaction and the quality of services will be improved the efficient management by supporting the real-time water leakage detection.

A Basic Study on the Improvement of Leakage Error of the Acoustic Intensity (음향 인텐시티의 누설오차 개선에 관한 기초적 연구)

  • 정의봉;정호경;안세진;윤상돈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.345-350
    • /
    • 2003
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidably have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed data of a harmonic signal with a single frequency is formulated when there is leakage error. The method to eliminate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

A Novel Method to Reduce Local Oscillator Leakage (국부발진기에서의 누설신호의 새로운 제거방식)

  • 이병제;강기조
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.294-301
    • /
    • 2000
  • One of the most important design parameters in a microwave radio transmitting system is to reduce spurious response from the output spectrum of the transmitting system. A Local oscillator (LO) is seldom totally pure and at the least contain some LO harmonic signals. A LO or any oscillator is a transmitter if provided with a suitable radiator, conduction, or leakage path. Where mixer is employed in the output of the LO mixer generated spurs can be increased by RF amplifier. To reduce LO leakage, notch filter or band pass filter has been conventionally used. In this paper, the leakage reduction(LR) signal, which has the same magnitude and the opposite phase with respect to LO leakage signal, is added to the output of mixer of the wireless LAN system. The LO leakage is reduced by 30 dB more than the conventional methods do. The proposed method is potentially suitable for low-cost, reliable, and simple application of monolithic microwave integrated circuits (MMICs)

  • PDF

A Study on Determining the Shape of Small Axial Cracks by using Magnetic Flux Leakage in NDT System for Underground Pipe (배관용 자기누설 비파괴 검사에서 축방향 미소결함의 형상 판정에 관한 연구)

  • Kim, Hui Min;Park, Gwan Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.1
    • /
    • pp.18-25
    • /
    • 2013
  • MFL PIG (Magnetic Flux Leakage Pipeline Inspection Gauge) is called the system which detects the defect for underground pipelines by using magnetic flux leakage method in nondestructive testing. This method is very suitable for testing pipelines because pipeline has high magnetic permeability. MFL PIG generates the magnetic fields to the pipe axially oriented, and detect the signal of leakage flux by using hall sensor. However, MFL PIG is hard to detect the axially oriented crack with small size because the magnetic flux leakage is not enough to be occurred. To detect the small size and axially oriented crack, the circumferential MFL (CMFL) PIG is being proposed and it can maximize the leakage flux for the axial crack by performing magnetic fields circumferentially on the pipe. In this paper, CMFL PIG is applied to detect the axially oriented crack with small size and the analysis for the distribution and the amplitude of the leakage flux signal is performed by using three dimensional finite element method. From sensing signals, the method how to determine the shape of axially oriented cracks is proposed and verified with experiment.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

Model-Based Detection of Pipe Leakage at Joints (모델 기반 파이프 연결부 누수 감지 시스템)

  • Kim, Taejin;Youn, Byeng D.;Woo, Sihyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.347-352
    • /
    • 2015
  • Time domain reflectometry (TDR) is widely used for wire failure detection. It transmits a pulse that is reflected at the boundaries of different characteristic impedances. By analyzing the reflected signal, TDR makes it possible to locate the failure. In this study, TDR was used to detect the water leakage at a pipe joint. A wire attached to the pipe surface was soaked by water when a leak occurred, which affected the characteristic impedance of the wet part, resulting in a change in the reflected signal. To infer the leakage from the TDR signal, we first developed a finite difference time domain-based forward model that provided the output of the TDR signal given the configuration of the transmission line. Then, by solving the inverse problem, the locations of the leaks were found.