• Title/Summary/Keyword: Leakage risk

Search Result 424, Processing Time 0.028 seconds

A CFD Study on the Hydrogen Leakage for Residential Fuel cell System (가정용 연료전지 시스템 내부의 수소 누출에 관한 전산해석)

  • Ahn, Jae-Uk;Chung, Tae-Yong;Shin, Dong-Hoon;Nam, Jin-Hyun;Kim, Young-Gyu;Park, Ju-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2026-2031
    • /
    • 2007
  • Hydrogen is receiving much research attention as an alternative substitute for hydrocarbon fuels these days due to its cleanliness and renewability. However, hydrogen should be used with caution because of its high propensity for leak and wide flammable range. This study deals with a situation that hydrogen leaks and then forms a flammable mixture inside 1kW class residential fuel cell. The residential fuel cell was modeled as a box-shaped chamber with vent openings at the top and bottom, filled with various components such as reformer, desulfurizer, fuel cell stack and humidifier. Computational fluid dynamics (CFD) was used to simulate the diffusion, buoyant flow and accumulation of leaked hydrogen in the modeled chamber. From the simulation, the risk region vulnerable to flame was identified and the methods to minimize such hazardous region was discussed. When the vent openings are 1% of the total surface, as the quantity of hydrogen leakage increases the risk regions increases accordingly. As the vent openings of the total surface increased from 1% to 2.3%, averaged hydrogen mole fraction is under 1% in the system.

  • PDF

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

Scheme on Environmental Risk Assessment and Management for Carbon Dioxide Sequestration in Sub-seabed Geological Structures in Korea (이산화탄소 해양 지중저장사업의 환경위해성평가관리 방안)

  • Choi, Tae-Seob;Lee, Jung-Suk;Lee, Kyu-Tae;Park, Young-Gyu;Hwang, Jin-Hwan;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2009
  • Carbon dioxide capture and storage (CCS) technology has been regarded as one of the most possible and practical option to reduce the emission of carbon dioxide ($CO_2$) and consequently to mitigate the climate change. Korean government also have started a 10-year R&D project on $CO_2$ storage in sea-bed geological structure including gas field and deep saline aquifer since 2005. Various relevant researches are carried out to cover the initial survey of suitable geological structure storage site, monitoring of the stored $CO_2$ behavior, basic design of $CO_2$ transport and storage process and the risk assessment and management related to $CO_2$ leakage from engineered and geological processes. Leakage of $CO_2$ to the marine environment can change the chemistry of seawater including the pH and carbonate composition and also influence adversely on the diverse living organisms in ecosystems. Recently, IMO (International Maritime Organization) have developed the risk assessment and management framework for the $CO_2$ sequestration in sub-seabed geological structures (CS-SSGS) and considered the sequestration as a waste management option to mitigate greenhouse gas emissions. This framework for CS-SSGS aims to provide generic guidance to the Contracting Parties to the London Convention and Protocol, in order to characterize the risks to the marine environment from CS-SSGS on a site-specific basis and also to collect the necessary information to develop a management strategy to address uncertainties and any residual risks. The environmental risk assessment (ERA) plan for $CO_2$ storage work should include site selection and characterization, exposure assessment with probable leak scenario, risk assessment from direct and in-direct impact to the living organisms and risk management strategy. Domestic trial of the $CO_2$ capture and sequestration in to the marine geologic formation also should be accomplished through risk management with specified ERA approaches based on the IMO framework. The risk assessment procedure for $CO_2$ marine storage should contain the following components; 1) prediction of leakage probabilities with the reliable leakage scenarios from both engineered and geological part, 2) understanding on physio-chemical fate of $CO_2$ in marine environment especially for the candidate sites, 3) exposure assessment methods for various receptors in marine environments, 4) database production on the toxic effect of $CO_2$ to the ecologically and economically important species, and finally 5) development of surveillance procedures on the environmental changes with adequate monitoring techniques.

  • PDF

Acidic Pelvic Drainage as a Predictive Factor For Anastomotic Leakage after Surgery for Patients with Rectal Cancer

  • Yang, Liu;Huang, Xin-En;Xu, Lin;Zhou, Xin;Zhou, Jian-Nong;Yu, Dong-Sheng;Li, Dong-Zheng;Guan, Xin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5441-5447
    • /
    • 2013
  • Purpose: To demonstrate the value of sequential determinations of pelvic drainage in the identification of increased risk of anastomotic leakage (AL) after anterior resection for rectal cancer with a double stapling technique. Patients and Methods: Between January 2004 and December 2011, data for the daily postoperative pH of pelvic drainage fluid in 753 consecutive patients with rectal cancer who initially underwent anterior resection with a double stapling technique were reviewed. All patients experienced a total mesorectal excision. Patients with anastomotic leakage (Group AL, n=57) were compared to patients without leakage (Group nAL, n=696). Patients with perioperatively abdominopelvic implants that were likely to affect pH value (determined at $25^{\circ}C$) other than leakage were excluded. Mean postoperative values were compared. Results: Anastomotic leakage was noted in 57 (7.6%) of 753 patients with rectal cancer. The diagnosis of AL was made between the $6^{th}$ and $12^{th}$ postoperative day (POD; mean $8^{th}$ POD). There was no significance of the daily average values of pH on POD1 & 2 in group AL while a significantly sharp declining mean pH value reached its diagnostic point of AL (p<0.001) on POD3. A cut-off value of 6.978 on the $3^{rd}$ POD maximized the sensitivity (98.7.0%) and specificity (94.7%) in assessing the risk of leakage. Conclusion: According to these results, an early and persistent declining of pH value of pelvic drainage fluid after rectal surgery with anastomosis, is a marker of AL. A cut-off value of 6.798 determined at $25^{\circ}C$ on POD3 maximizes sensitivity and specificity.

Fire Safety Assessment Based on FSA and Risk Reduction of Machinery System Considering Functional Safety (기능적 안전을 고려한 FSA기반 기관 구역 화재 안전성 평가 및 개선)

  • Suh, Sung-Won;Yang, Young-Soon;Chung, So-Yeon;Ryu, Won-Sun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.3
    • /
    • pp.239-246
    • /
    • 2012
  • It is the well-known fact that most part of goods transported are moved on the unfavorable ocean and even a small amount of accident on sea is extremely dangerous for human lives, financial losses, and social responsibility. Among the several causes of accidents, those by fire have occurred frequently and their damage has been highly serious. The aim of this paper is to assess the risk of fires due to oil leakage in the machinery space. To define the possible fire scenario, our team has performed the search of casualty database and reviewed the previous and various studies in the field. As a result, it is noted that the quantitative risk of the fire scenario have been evaluated on the ground of the FSA risk model. The expected frequency of a fire amounts to incidents during the life of a ship, and the expected financial damage amounts to 5,654 USD per a ship. By adopting Safety Instrumented System (SIS) introduced in IEC 61508 and IEC 61511, SIS model is designed to prevent oil leakage fire as a risk reduction method. It is concluded that System Integrity Level (SIL) 1 seems to be appropriate level of SIS.

Comparison of Early Clinical Results of Transcatheter versus Surgical Aortic Valve Replacement in Symptomatic High Risk Severe Aortic Stenosis Patients

  • Yu, Woo Sik;Chang, Byung-Chul;Joo, Hyun Chel;Ko, Young-Guk;Lee, Sak
    • Journal of Chest Surgery
    • /
    • v.46 no.5
    • /
    • pp.346-352
    • /
    • 2013
  • Background: Transcatheter aortic valve implantation (TAVI) has been an alternative to conventional aortic valve replacement (AVR) in old and high risk patients. The goal of this study is to compare the early outcomes of conventional AVR vs. TAVI in high risk severe AS patients. Methods: From January 2008 to July 2012, 44 high risk severe aortic stenosis patients underwent conventional AVR, and 15 patients underwent TAVI. We compared echocardiographic data, periprocedural complication, and survival. The mean follow-up duration was $14.5{\pm}10$ months (AVR), and $6.8{\pm}3.5$ months (TAVI), respectively. Results: AVR group was younger ($78.2{\pm}2.4$ years vs. $82.2{\pm}3.0$ years, p<0.001) and had lower operative risk (Euroscore: $9.4{\pm}2.7$ vs. $11.0{\pm}2.0$, p=0.044) than TAVI group. There was no significant difference in early mortality (11.4% vs. 13.3%, p=0.839), and 1 year survival ($87.4%{\pm}5.3%$ vs. $83.1%{\pm}1.1%$, p=0.805). There was no significant difference in postoperative functional class. There was no significant difference in periprocedural complication except vascular complication (0% [AVR] vs. 13.3% [TAVI], p=0.014). TAVI group had more moderate and severe paravalvular leakage. Conclusion: In this study, both groups had similar periprocedural morbidity, and mortality. However, TAVI group had more greater than moderate paravalvular leakage, which can influence long-term outcome. Since more patients are treated with TAVI even in moderate risk, careful selection of the patients and appropriate guideline need to be established.

SIS Design for Fuel Gas Supply System of Dual Fuel Engine based on Safety Integrity Level(SIL) (이중연료엔진의 연료가스공급시스템에 대한 안전무결도 기반 안전계장시스템 설계)

  • Kang, Nak-Won;Park, Jae-Hong;Choung, Choung-Ho;Na, Seong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.447-460
    • /
    • 2012
  • In this study, the shutdown system of the fuel gas supply system is designed based on the Safety Integrity Level of IEC 61508 and IEC 61511. First of all, the individual risk($10^{-4}$/year) and the risk matrix which are the risk acceptance criteria are set up for the qualitative risk assessment such as the HAZOP study. The natural gas leakage at the gas supply pipe is identified as the highest risk among the hazards identified through the HAZOP study and as a safety instrumented function the shutdown function for leakage was defined. SIL 2 and PFD($2.5{\cdot}10^{-3}$) for the shutdown function are determined by the layer of protection analysis(LOPA). The shutdown system(SIS) carrying out the shutdown function(SIF) is verified and designed according to qualitative and quantitative requirements of IEC 61508 and IEC 61511. As a result of SIL verification and SIS conceptual design, the shutdown system is composed of two gas detectors voted 1oo2, one programmable logic solver, and two shutdown valve voted 1oo2.

FTA of Leakage Path in Subsea X-mas Tree System (해저 유정 제어 시스템에서의 누수 경로 FTA 분석)

  • Yoo, Won-Woo;Park, Min-Sun;Yang, Young-Soon;Ruy, Won-Sun;Jang, Beom-Seon
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.85-90
    • /
    • 2013
  • The growing need for energy (oil and gas) has led to offshore resource development. As a reflection of this trend, there have been many advances in the technologies used for the subsea production systems that make offshore resource development possible. As the technologies for subsea production systems continue to grow, a subsea X-mas tree, the core equipment in a subsea production system, is required to have more functions than before. Generally, these complex functions lead to a change in its configuration. Therefore, this paper investigates a change in a subsea X-mas tree system to enhance system understanding, and conducts a leakage path analysis of a subsea X-mas tree system. Utilizing the recent configuration of the subsea X-mas tree, an identification of the leakage path and a quantitative risk analysis for the leakage using an FTA (fault tree analysis) are conducted.

Damage Effects Modeling by Chlorine Leaks of Chemical Plants (화학공장의 염소 누출에 의한 피해 영향 모델링)

  • Jeong, Gyeong-Sam;Baik, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.76-87
    • /
    • 2018
  • This study describes the damage effects modeling for a quantitative prediction about the hazardous distances from pressurized chlorine saturated liquid tank, which has two-phase leakage. The heavy gas, chlorine is an accidental substance that is used as a raw material and intermediate in chemical plants. Based on the evaluation method for damage prediction and accident effects assessment models, the operating conditions were set as the standard conditions to reveal the optimal variables on an accident due to the leakage of a liquid chlorine storage vessel. A model of the atmospheric diffusion model, ALOHA (V5.4.4) developed by USEPA and NOAA, which is used for a risk assessment of Off-site Risk Assessment (ORA), was used. The Yeosu National Industrial Complex is designated as a model site, which manufactures and handles large quantities of chemical substances. Weather-related variables and process variables for each scenario need to be modelled to derive the characteristics of leakage accidents. The estimated levels of concern (LOC) were calculated based on the Gaussian diffusion model. As a result of ALOHA modeling, the hazardous distance due to chlorine diffusion increased with increasing air temperature and the wind speed decreased and the atmospheric stability was stabilized.

Implementation of ELB Leakage Current Control System based on ZigBee Communication (ZigBee통신 기반 ELB 누전전류 제어시스템 구현)

  • Ju, Jae-Han
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.52-57
    • /
    • 2012
  • Social development as well as the development of consumer electronic devices due to leakage, electric shock or fire, and many are exposed to the risk of leakage currents. Premises in the control cabinet, but the circuit breaker is installed, the existing circuit breaker shuts off when a short circuit in the control cabinet, installed only have the capability. Also connected to the outlet is installed byeokmada family of devices is not easy thing to check individually. In this paper, circuit breakers and circuit analysis and circuit performance, ZigBee-based premises of consumer electronics devices using sensors to monitor the health of the leakage can be presented on how. Performance analysis, the proposed ELB leakage current control system is built into the appliance leakage circuit breaker for each household appliances because the application can check the status of a short circuit, short circuit, over the existing system can be monitored easily.