• Title/Summary/Keyword: Leakage risk

Search Result 424, Processing Time 0.031 seconds

A Study on Risk Influence Factors of Ground Subsidence through Soil Investigation Analysis (지반조사 분석을 통한 지반함몰 위험영향인자 연구)

  • Joung, Ho Young;Lee, Gil Hwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.43-46
    • /
    • 2017
  • Recently, the development of underground space is being actively carried out in the urban area by saturation, and the excavation works are mainly carried out by various excavation methods by the structures adjacent to the ground and underground excavation. During such excavation work, ground subsidence accidents are occurring due to inattention construction, lack of construction technology, and leakage of ground water. For the prevention of ground subsidence we studied the method of risk influence factors by soil investigation. Analysis of 75 sites soil investigation by U.S.C.S (Unified Soil Classification System), construction method, depth of excavation and we studied the risk influence factors with ground subsidence.

A Study on the Electrical Fire Risk Assessment Methods of LED Lightings for Outdoor (옥외용 LED 조명의 전기화재 위험성 평가기법에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.674-679
    • /
    • 2011
  • In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts(connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.

Risk Factors of Recurrent Spontaneous Pneumothorax (자연기흉의 개발위험인자)

  • Hong, Eun-Pyo;Park, Lee-Tae;Han, Seung-Se
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.533-540
    • /
    • 1992
  • To evaluate the risk factors involving the recurrence of the spontaneous pneumothorax, 125 patients were reviewed. These patients were consecutively diagnosed and treated for the spontaneous pneumothorax at the Department of Thoracic and Cadiovascular Surgery, Yeungnam University Hospital, from Jun. 1986 to Apr. 1991. The patients were divided into two groups, control and recurrent. The control group, consisting of the 125 patients, did not have recurrences of the pneumothorax for a period of 2 years following the first attack. The recurrent group were the remaining 57 patients, who experienced at least one recurrence during the same period. The number of patients over the age of 50 was significantly higher in the recurrent group than the control group. Abnormal findings on chest X-ray[e.g., old tuberculous scar, emphysematous change, visible bullae of blebs] were observed more frepuently in the recurrent group. also, when the pneumothorax size was larger than 50%, and the air-leakage from the chest tube was longer than 3 days during the first attack the incidence of recurrence was significantly increased in the recurrent group. The recurrence occured more frequently in the afternoon, and in the same thoracic cavity. Exertion and smoking were not related to the risk factors in this clinical setting.

  • PDF

Treatment Outcomes of Traumatic Duodenal Injury (외상성 십이지장 손상의 치료 성적)

  • Yu, Byunghyuk;Cho, Jayun;Lim, Kyoung Hoon;Park, Jinyoung
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.129-133
    • /
    • 2015
  • Purpose: The purpose of this study is to evaluate the surgical outcome of duodenal injuries and to analyze the risk factors related to the leakage after surgical treatment. Methods: A retrospective review of 31 patients with duodenal injuries who managed by surgical treatment was conducted from December 2000 to May 2014. The demographic characteristics, injury mechanism, site of duodenal injury, association of intraabdominal organ injuries, injury severity score (ISS), abdominal abbreviated injury scale (AIS), injury-operation time lag, surgical treatment methods, complications, and mortality were reviewed. Results: Duodenal injury was more common in male. Twenty four (77.4%) patients were injured by blunt trauma. The most common injury site was in the second portion of the duodenum (n=19, 58.6%). Fourteen patients (45.2%) had other associated intraabdominal organ injuries. The mean ISS is $13.6{\pm}9.6$. The mean AIS is $8.9{\pm}6.5$. Eighteen patients (58.1%) were treated by primary closure. The remaining 13 patients underwent various operations, including exploratory laparotomy (n=4), pancreaticoduodenectomy (n=3), pyloric exclusion (n=3), Resection with end-to-end anastomosis (n=2), and duodenojejunostomy (n=1). Most common postoperative complications were intraabdominal abscess (n=9) and renal failure (n=9). Mortality rate was 9.7%. Conclusion: ISS, AIS>10, operative time, pancreaticoduodenectomy, sepsis, and renal failure are significant predictors of a postoperative leak after duodenal injury. Careful management is needed to prevent a potential leak in patient with these findings.

  • PDF

A Case of Balloon Kyphoplasty in High Risk under Cement Leakage -A case report- (시멘트 누출 위험성이 높은 환자에서의 풍선 척추몸통뼈 복원술 -증례보고-)

  • Choi, Yun Suk;Lee, Mi Geum;Lee, Hyo Min;Jo, Ji Yon;Jeong, Hee Jin;Lee, Chul Joong;Lee, Sang Chul;Kim, Yong Chul;Sim, Sung Eun
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.261-265
    • /
    • 2006
  • A vertebral compression fracture can cause chronic back pain, and may also result in progressive kyphosis. The traditional treatments of a vertebral compression fracture include bed rest, analgesics and bracing. Balloon kyphoplasty can restore the vertebral height and allow safe bone cement injection into the cavity made by the balloon, which significantly reduces the risk of cement leakage compared to vertebroplasty. An 82-year-old female patient suffered from severe low back pain. Due to the intractable pain and immobility, which could not be relieved by conventional care, as well as the empty vertebral body associated with communicated fractures of the vertebral surfaces, balloon kyphoplasty, with a thicker bone cement injection than usual with balloon kyphoplasty, was chosen. The preoperative intractable pain and immobility were dramatically relieved soon after the procedure, without any complications.

A Study on Removal Request of Exposed Personal Information (노출된 개인정보의 삭제 요청에 관한 연구)

  • Jung, Bo-Reum;Jang, Byeong-Wook;Kim, In-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.37-42
    • /
    • 2015
  • Although online search engine service provide a convenient means to search for information on the World Wide Web, it also poses a risk of disclosing privacy. Regardless of such risk, most of users are neither aware of their personal information being exposed on search results nor how to redress the issue by requesting removal of information. According to the 2015 parliamentary inspection of government offices, many government agencies were criticized for mishandling of personal information and its leakage on online search engine such as Google. Considering the fact that the personal information leakage via online search engine has drawn the attention at the government level, the online search engine and privacy issue needs to be rectified. This paper, by examining current online search engines, studies the degree of personal information exposure on online search results and its underlying issues. Lastly, based on research result, the paper provides a sound policy and direction to the removal of exposed personal information with respect to search engine service provider and user respectively.

A Study on Synthetic Data Generation Based Safe Differentially Private GAN (차분 프라이버시를 만족하는 안전한 GAN 기반 재현 데이터 생성 기술 연구)

  • Kang, Junyoung;Jeong, Sooyong;Hong, Dowon;Seo, Changho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.5
    • /
    • pp.945-956
    • /
    • 2020
  • The publication of data is essential in order to receive high quality services from many applications. However, if the original data is published as it is, there is a risk that sensitive information (political tendency, disease, ets.) may reveal. Therefore, many research have been proposed, not the original data but the synthetic data generating and publishing to privacy preserve. but, there is a risk of privacy leakage still even if simply generate and publish the synthetic data by various attacks (linkage attack, inference attack, etc.). In this paper, we propose a synthetic data generation algorithm in which privacy preserved by applying differential privacy the latest privacy protection technique to GAN, which is drawing attention as a synthetic data generative model in order to prevent the leakage of such sensitive information. The generative model used CGAN for efficient learning of labeled data, and applied Rényi differential privacy, which is relaxation of differential privacy, considering the utility aspects of the data. And validation of the utility of the generated data is conducted and compared through various classifiers.

A Study on Acceptance of Public Recording for SNS Post (SNS 게시물에 대한 공공기록화 수용에 관한 연구)

  • Yun, Sung-Uk;Chang, Jun-Gab;Kim, Geon
    • Journal of Digital Convergence
    • /
    • v.17 no.9
    • /
    • pp.1-12
    • /
    • 2019
  • This study explored the factors affecting the acceptance of public recording in SNS post. Using SPSS 21.0 program and AMOS 21.0 program, major results were derived through exploratory factor analysis, confirmatory factor analysis, correlation analysis, and path analysis. The results are as follows: First, the risk of personal information leakage on SNS posting has a significant negative impact on the attitude toward SNS posting. Second, the security of the SNS posting has a significant effect on the attitude toward the SNS posting. Third, the concern about privacy of SNS posting has a significant negative impact on the attitude toward SNS posting. Fourth, the attitude toward SNS posting has a significant effect on the intention to accept the SNS posting. The above results suggest that the SNS post recording should be able to collect opinions of SNS users from a long-term viewpoint.

Privacy Leakage Monitoring System Design for Privacy Protection (개인정보보호를 위한 개인정보 유출 모니터링 시스템의 설계)

  • Cho, Sung-Kyu;Jun, Moon-Seog
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.1
    • /
    • pp.99-106
    • /
    • 2012
  • Numerous private corporations and public institutions are collecting personal information through the diverse methods for the purpose of sales, promotion and civil services, and using personal information for the profits of the organizations and services. However, due to immaturity of the technical, managerial measures and internal control for the collected personal information, the misuse, abuse and the leaks of personal information are emerged as major social issues, and the government also is promoting implementation of the act on the privacy protection by recognizing the importance of the personal information protection. This research describes on the measures to detect the anomaly by analyzing personal information treatment patterns managed by the organizations, and on the measures to coup with the leaks, misuse, and abuse of personal information. Particularly, this research is intended to suggest privacy leakage monitoring system design, which can be managed by making the elements related to personal information leaks to numeric core risk indexes to be measured objectively.

A Comparison on Detected Concentrations of LPG Leakage Distribution through Actual Gas Release, CFD (FLACS) and Calculation of Hazardous Areas (가스 누출 실험, CFD 및 거리산출 비교를 통한 LP가스 누출 검지농도 분포에 대한 고찰)

  • Kim, Jeong Hwan;Lee, Min-Kyeong
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.102-109
    • /
    • 2021
  • Recently, an interest in risk calculation methods has been increasing in Korea due to the establishment of classification code for explosive hazardous area on gas facility (KGS CODE GC101), which is based on the international standard of classification of areas - explosive gas atmospheres (IEC 60079-10-1). However, experiments to check for leaks of combustible or toxic gases are very difficult. These experiments can lead to fire, explosion, and toxic poisoning. Therefore, even if someone tries to provide a laboratory for this experiment, it is difficult to install a gas leakage equipment. In this study we find out differences among actual experiments, CFD by using FLACS and calculation based on classification code for explosive hazardous area on gas facility (KGS CODE GC101) by comparing to each other. We develpoed KGS HAC (hazardous area classification) program which based on KGS GC101 for convenience and popularization. As a result, actual gas leak, CFD and KGS HAC are showing slightly different results. The results of dispersion of 1.8 to 2.7 m were shown in the actual experiment, and the CFD and KGS HAC showed a linear increase of about 0.4 to 1 m depending on the increase in a flow rate. In the actual experiment, the application of 3/8" tubes and orifice to take into account the momentum drop resulted in an increase in the hazardous distance of about 1.95 m. Comparing three methods was able to identify similarities between real and CFD, and also similarities and limitations of CFD and KGS HAC. We hope these results will provide a good basis for future experiments and risk calculations.