• Title/Summary/Keyword: Leakage characteristics

Search Result 1,665, Processing Time 0.024 seconds

The Method of Certificating Waterproof Effect for Consecutive Column-Wall Mass in Underground (주열식 지중연속벽체의 차수효과 확인 방안)

  • Koh, Yong-IL
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.9
    • /
    • pp.5-9
    • /
    • 2017
  • On the flow of groundwater, the effect of consecutive column-wall in underground as a hydraulic barrier could be identified by conventional geotechnical methods ((1)visualiy identification of wall mass after underground excavating, (2)uniaxial compressive strength test for core of wall mass in underground, (3)in-situ permeability test in the hole after coring wall mass). However, for the cut off the leakage or infiltration of very high concentrated leachate from the waste landfill or the contaminated groundwater, the waterproof effect of consecutive column-wall in underground should be verified more objectively, by in-situ measuring of pH, temperature and salinity. and by evaluating of their consistency and similarity throughout analyzing the characteristics of basic components and their profiles through the series of chemical experiments. Furthermore, its waterproof effect could be verified additionally throughout deciding the similarity more simply by comparing the general distribution patterns including the difference of high and low peaks from the chromatograms using GC-MS for surrounding groundwater.

Influence of Dy2O3 Addition on Microstructure and Electrical Properties of Pr6O11 Varistor Ceramics (Pr6O11계 ZnO 바리스터 세라믹스의 미세구조 및 전기적 특성에 미치는 Dy2O3첨가의 영향)

  • Nahm, Choon-Woo;Park, Jong-Ah
    • Korean Journal of Materials Research
    • /
    • v.13 no.10
    • /
    • pp.645-650
    • /
    • 2003
  • The microstructure and electrical characteristics of $Pr_{6}$ $O_{11}$ -based ZnO varistor ceramics composed of $ZnO-Pr_{6}$ $O_{ 11}$/$-CoO-Cr_2$$O_3$-$Dy_2$$O_3$-based ceramics were investigated with $Dy_2$$O_3$content in the range of 0.0∼2.0 mol%. As $Dy_2$$O_3$content was increased, the average grain size was decreased in the range of 18.6∼4.7 $\mu\textrm{m}$ and the density of the ceramic was decreased in the range of 5.53∼4.34 g/㎤. While, the varistor voltage was increased in the range of 39.4∼436.6 V/mm and the nonlinear exponent was in the range of 4.5∼66.6 with increasing $Dy_2$$O_3$content. The addition of $Dy_2$$O_3$highly enhanced the nonlinear properties of varistors, compared with the varistor without $Dy_2$$O_3$. In particular, the varistor with $Dy_2$$O_3$ content of 0.5 mol% exhibited the highest nonlinearity, in which the nonlinear exponent is 66.6 and the leakage current is 1.2 $\mu\textrm{A}$. The donor concentration and the density of interface states were decreased in the range of $(4.19∼0.33) ${\times}$10^{18}$ //㎤ and $(5.38∼1.74) ${\times}$10^{12}$ $\textrm{cm}^2$, respectively, with increasing $Dy_2$$O_3$content. The minimum dissipation factor of 0.0302 was obtained from 0.5mol% $Dy_2$$O_3$.

Preparation of Shape Stabilized PCM Using Porous Materials for Application to Buildings (건축적용을 위한 다공성 물질을 이용한 상안정 PCM 제조)

  • Jeong, Su-Gwang;Yu, Seulgi;Jang, Seulae;Park, Jin-Sung;Kim, Taehyun;Lee, Jeong-Hun;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.432-437
    • /
    • 2013
  • The increase of greenhouse gas emission and decrease of fossil fuel are being caused by the indiscreet consumption of energy by people. Recently, green policy has been globally implemented to reduce energy consumption. This paper studied the research to reduce the energy consumption in buildings, by using the heat storage properties of PCM. PCM has to prevent leakage from the liquid state. Therefore, we prepared form stable PCM, by using the vacuum impregnation method. Three kinds of organic PCMs were impregnated into the structure of porous material. The characteristics of the composites were determined by using SEM, DSC, FTIR and TGA. SEM morphology showed the micro structure of silica fume/PCM. Also, thermal properties were examined by DSC and TGA analyses; and the chemical bonding of the composite was determined by FTIR analysis.

Analysis of Thermomechanical Properties Considering the Thermal Expansion Anisotropy of Membrane-Type Fiber-Reinforced Composite Material (멤브레인 형 섬유강화 복합재료의 열팽창 이방성을 고려한 열 기계적 특성 분석)

  • Jeong, Yeon-Jae;Kim, Hee-Tae;Kim, Jeong-Dae;Oh, Hoon-Gyu;Kim, Yong-Tai;Park, Seong-Bo;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • The membrane-type Liquefied Natural Gas (LNG) cargo tank is equipped with a double barrier to seal the LNG, of which the secondary barrier serves to prevent LNG leakage and mainly uses fiber-reinforced composite materials. However, the composite materials have thermal expansion anisotropy, which deteriorates shape distortion and mechanical performance due to repeated thermal loads caused by temperature changes between cryogenic and ambient during the unloading of LNG. Therefore, in this study, the longitudinal thermal expansion characteristics of the composite materials were obtained using a vertical thermo-mechanical analyzer, and the elastic modulus was obtained through the tensile test for each temperature to perform thermal load analysis for each direction. This is considered that it is useful to secure reliability from the viewpoint of the design of materials for a LNG cargo hold.

Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance (제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가)

  • Lee, Yeon-Gun;Heo, Jaehyeok;Lee, Dong-Won;Hyun, Myung-Taek
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.70-79
    • /
    • 2018
  • A heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO was constructed with the capacity of 300 RT to supply cool or hot water to greenhouse facilities located 3 km from the power station. The way of transporting heat from the thermal effluent to greenhouses at a long distance was optimized, and a monitoring system to measure the water temperature and detect a leakage in a pipe conduit was also installed. This paper presents the system configuration of the constructed heat pump system for air conditioning and heating of greenhouse facilities in Jeju, and the characteristics of major components deployed in the system. The preoperational tests of the heat pump system were conducted during the summer season in 2018 for evaluation of its cooling performance. The operational stability and cooling performance of the heat pump system were confirmed by investigating the measured fluid temperature and flow rate, and COP of the heat pump in a cooling mode.

A study on working out arc detector related regulations (아크 검출기 관련 규정 마련에 관한 연구)

  • Park, Yong-Seo
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.115-122
    • /
    • 2018
  • More than 70% of the electric fire cases happen in this country are caused by arc. This paper aims to prepare measures of preventing electric fires resulted from arc by analyzing the technical standards and related regulations on the existing circuit breaker. Based on the study, we concluded that the technical and legal standards of the arc detector should be separately regulated from those of existing circuit breaker, considering the characteristics of arc detectors. Accordingly, we suggested in this paper that the arc detector related regulations should either be added to the existing circuit breaker related regulations, or to be handled separately. For effective prevention of electric fires caused by arc, it is urgently required to install arc detector and it is, therefore, appropriate to make it mandatory to install an arc detector. Under the given circumstance, it is suggested that the arc detector related regulations should be added to the existing regulations for the circuit breaker. The technical standards of arc detectors should reflect the arc judgement specification, breaking threshold of arc and the range of unnecessary signal that breaker should not react to respond.

A Novel Technique of Hand-Sewn Purse-String Suturing by Double Ligation Method (DLM) for Intracorporeal Circular Esophagojejunostomy

  • Takayama, Yuichi;Kaneoka, Yuji;Maeda, Atsuyuki;Fukami, Yasuyuki;Takahashi, Takamasa;Uji, Masahito
    • Journal of Gastric Cancer
    • /
    • v.19 no.3
    • /
    • pp.290-300
    • /
    • 2019
  • Purpose: The optimal method for intracorporeal esophagojejunostomy remains unclear because a purse-string suture for fixing the anvil into the esophagus is difficult to perform with a laparoscopic approach. Therefore, this study aimed to evaluate our novel technique to fix the anvil into the esophagus. Materials and Methods: This retrospective study included 202 patients who were treated at our institution with an intracorporeal circular esophagojejunostomy in a laparoscopy-assisted total gastrectomy with a Roux-en-Y reconstruction (166 cases) or a laparoscopy-assisted proximal gastrectomy with jejunal interposition (36 cases). After incising 3/4 of the esophageal wall, a hand-sewn purse-string suture was placed on the esophagus. Next, the anvil head of a circular stapler was introduced into the esophagus. Finally, the circular esophagojejunostomy was performed laparoscopically. The clinical characteristics and surgical outcomes were evaluated and compared with those of other methods. Results: The average operation time was 200.3 minutes. The average hand-sewn purse-string suturing time was 6.4 minutes. The overall incidence of postoperative complications (Clavien-Dindo classification grade ${\geq}II$) was 26%. The number of patients with an anastomotic leakage and stenosis at the esophagojejunostomy site were 4 (2.0%) and 12 (6.0%), respectively. All patients with stenosis were successfully treated by endoscopic balloon dilatation. There was no mortality. Regarding the materials and devices for anvil fixation, only 1 absorbable thread was needed. Conclusions: Our procedure for hand-sewn purse-string suturing with the double ligation method is simple and safe.

Tag Identification Time Reduction Scheme of Back-End Server for Secure RFID Privacy Protection Protocol (안전한 RFID 프라이버시 보호 프로토콜을 위한 백엔드 서버의 태그 판별 시간 절감 기법)

  • Yeo Sang-Soo;Kim Soon-Seok;Kim Sung-Kwon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.4
    • /
    • pp.13-26
    • /
    • 2006
  • RFID technology is evaluated as one of core technologies for ubiquitous environment, because of its various characteristics which barcode systems don't have. However, RFID systems have consumer's privacy infringement problems, such like information leakage and location tracing. We need RFID privacy protection protocols, that satisfy three essential security requirements; confidentiality, indistinguishability and forward security, in order to protect consumer's privacy perfectly. The most secure protocol, that satisfies all of the three essential security requirements, among existing protocols, is the hash-chain based protocol that Ohkubo proposed. Unfortunately this protocol has a big disadvantage that it takes very long time to identify a tag in the back-end server. In this paper, we propose a scheme to keep security just as it is and to reduce computation time for identifying a tag in back-end server. The proposed scheme shows the results that the identification time in back-end server is reduced considerably compared to the original scheme of Ohkubo protocol.

Unplanned Reoperation Rate at a Government-Designated Regional Trauma Center in Gangwon Province

  • Kim, Minju;Kim, Seongyup
    • Journal of Trauma and Injury
    • /
    • v.34 no.1
    • /
    • pp.39-43
    • /
    • 2021
  • Purpose: Determining appropriate ways to assess health care quality within the National Health Insurance System is of interest to both the Korean government and the medical community. However, in the trauma field, the number of indicators used to evaluate surgical quality is limited. Using data collected over 5 years at Wonju Severance Christian Hospital Trauma Center in Korea, this study aimed to determine whether the unplanned reoperation rate in the field of trauma surgery could be used to assess the quality of an institution's surgical care. Methods: In total, 665 general surgical procedures were performed at the Trauma Center in 453 patients with abdominopelvic injuries from January 2015 to December 2019. Data were collected from the Trauma Center's data registry and medical records, and included information regarding patients' demographic characteristics, the type of index operation, and the reason for unplanned reoperations. Results: A total of 453 index operations were evaluated. The proportion of patients with an Injury Severity Score (ISS) >15 was 48-70% over the 5-year period, with an unplanned reoperation rate of 2.1-9.3%. Patients had an average ISS score of 17.5, while the average Abbreviated Injury Scale Score was 2.87. Unplanned reoperations were required in about 7% of patients. The most common complications requiring reoperation were recurrent bleeding (26.9%), wound problems (26.9%), intestinal infarction (15.4%), and anastomosis site leakage (7.7%). The procedures most frequently requiring unplanned reoperations were bowel surgery (segmental resection, primary repair, enterostomy, etc.) (24.5%) and preperitoneal pelvic packing (10.6%). Conclusions: The proportion of reoperations was confirmed to be affected by injury severity.

Impact of Esophagojejunal Reconstruction without Division of the Mesentery for Total Laparoscopic Total Gastrectomy

  • Ko, Chang Seok;Jheong, Jin Ho;Lee, In-Seob;Kim, Beom Su;Kim, Min-Ju;Yoo, Moon-Won
    • Journal of Gastric Cancer
    • /
    • v.21 no.1
    • /
    • pp.63-73
    • /
    • 2021
  • Purpose: This study aimed to compare the surgical outcomes of total laparoscopic total gastrectomy without mesentery division (LTG without MD) and conventional total laparoscopic total gastrectomy (CLTG), as well as evaluate the appropriate method for esophagojejunostomy (EJ) reconstruction after total laparoscopic total gastrectomy (TLTG). Materials and Methods: We retrospectively analyzed data from 301 consecutive patients who underwent TLTG for upper or middle third gastric cancer between January 2016 and May 2019. After propensity score matching, 95 patients who underwent LTG without MD and 95 who underwent CLTG were assessed. Data on clinical characteristics and surgical outcomes, including operation time, length of postoperative hospital stay, pathological findings, and postoperative complications were analyzed. Results: The LTG without MD group showed a shorter time to first flatus (3.26±0.80 vs. 3.62±0.81 days, P=0.003) and a shorter time to soft diet (2.80±2.09 vs. 3.52±2.20 days, P=0.002). The total EJ-related complications in the LTG without MD group were comparable to those in the CLTG group (9.47% vs. 3.16%, P=0.083). EJ-related leakage (6.32% vs. 3.16%, P=0.317) and EJ-related stricture (3.16% vs. 1.05%, P=0.317) rates were not significantly different between the LTG without MD and CLTG groups. No significant differences were found between the two groups in terms of other early surgical outcomes such as early complications, late complications, hospital stay, and readmission rate. Conclusions: LTG without MD is a safe surgical treatment for upper or middle third gastric cancer. LTG without MD may be an alternative procedure for EJ anastomosis during TLTG.