• Title/Summary/Keyword: Leakage analysis FEM

Search Result 85, Processing Time 0.026 seconds

Development of the Automobile Part for the Engine Oil Leakage Prevention by the Precise Cold Forging (정밀냉간단조에 의한 엔진오일 누수방지용 자동차부품 개발)

  • Kwon H. B.;Lee B. K.
    • Transactions of Materials Processing
    • /
    • v.14 no.8 s.80
    • /
    • pp.675-680
    • /
    • 2005
  • This study was aimed at the design of the dies for the automobile part for the engine oil leakage prevention using the computer simulation to shorten the period of production, on the basis of the process planning which was designed by the field experts. In the computer simulation,'eesy-2-form' of 2D FEM simulation package and 'eesy-DieOpt' have been used, which are the commercial process analysis and die design program. Through the simulation of 'eesy-2-form', we could know the propriety of the forming process, the inner pressure of the die and the suitable fitting pressure between the insert and the sleeve which was not showing any positive tangential stresses in the insert. Through the simulation of 'eesy-DieOpt', we could know the number of the stress ring, the diameter ratios, the stresses of the die, the shrink fitting tolerance and temperature in the condition of the already determined maximum outer die diameter of the multi-stage former. The validity of the die design using the computer simulation was analyzed by the experiments and the results were satisfactory. As the results of this study, the new and easy die design system for cold forging has been developed.

Parameter Design of The Magnet Gear with A Closed Magnetic Path (자기 폐회로를 갖는 마그네트 기어의 변수 설계)

  • Jung, Kwangsuk
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.2
    • /
    • pp.7-12
    • /
    • 2015
  • A novel topology for the magnet gear is proposed in this study. Differently from the existing methods, both sides of magnet array in this topology are used, resulting in increasing the efficiency of the mechanism. The closed magnetic path between the magnetic elements decreases the leakage flux, so the interlinking magnetic flux through the air-gap is focused and intensified. This paper discusses the dominant parameters of the proposed magnet gear influencing the resulting transmission torque. The parameters are designed from the sensitivity analysis using the commercial FEM analysis tool. And, the test setup for verifying the performance of the system is described.

FEM Analysis and Dynamic Characteristics of Hydraulic Pump Assembly Components for Aircraft (항공기용 유압 펌프 부품의 동적특성 및 유한 요소 분석)

  • Kim, H.E.;Han, S.G.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.5-11
    • /
    • 2012
  • In this paper, the numerical analysis is introduced to predict the dynamic characteristics of piston pump assembly components in hydraulic piston pump for aircraft. Rotating cylinder block and reciprocating pistons are modelled kinematically. Furthermore, leakage flow and torque losses between the boundary surfaces of components are analyzed. This analysis has been carried out through the commercial CASPAR program. The simulations for stress on pump assembly components using the dynamic analysis model are performed using the ANSYS 11 program. Such dynamic characteristics and stress simulation procedures will be carried out repeatedly for the optimized design.

Characteristic Analysis of a Linear Induction Motor for a Lightweight Train According to Various Secondary Schemes

  • Lee, Hyung-Woo;Lee, Sung-Gu;Park, Chan-Bae;Lee, Ju;Park, Hyun-June
    • International Journal of Railway
    • /
    • v.1 no.1
    • /
    • pp.6-11
    • /
    • 2008
  • This paper presents a performance characteristic analysis methodology for a linear induction motor used for a lightweight train. In general, an analytical method cannot provide accurate results in a linear motor because of large airgap, end effect, transverse edge effect, 3-dimensional configurations, large leakage, and so on. Besides, a numerical method requires lots of memory and solving time for transient analysis. However, the suggested methodology which is a kind of hybrid solution with an analytical method and a numerical method is very fast and accurate. Based on the methodology, 3-D FEM analyses for various design schemes of the secondary reaction plate have been done and from the analysis results, the best configuration for an urban railway transit is chosen.

  • PDF

A study on the safety improvement of above ground membrane LNG storage tank (상지상식 멤브레인 액화천연가스 저장탱크의 안전성 향상 방안)

  • Lee, Seung Rim;Kim, Han Sang
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.339-345
    • /
    • 2012
  • RMembrane LNG storage tanks have been recently investigated to replace full-containment LNG storage tanks because of safety and cost aspects. Quantitative Risk Analysis (QRA) and Finite Element Method (FEM) were used to evaluate safety of membrane LNG storage tanks. In this study, structural safety evaluation results via FEM analysis showed that both membrane type and full-containment type cryogenic LNG storage tanks with 140,000 $m^3$ capacity were equivalently safe in terms of strength safety and leakage safety of a storage tank system. Also, Fault Tree Analysis (FTA) was used to improve the safety of membrane LNG storage tanks and membrane LNG tanks were modified by adding three safety equipments: impact absorber structure for the low part of the membrane, the secondary barrier to diminish the thermal stress of the corner part of the outer tank, and a pump catcher in case of falling of a pump. Consequently, the safety of the modified membrane LNG storage tanks were proved to be equivalent to that of full-containment LNG storage tanks.

Thermo-hydraulic Numerical Analysis for the Leakage of Buried District Heating Pipe (열수송관의 누수에 대한 열-수리적 수치해석)

  • Shin, Hosung;Hong, Seung-Seo
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.3
    • /
    • pp.17-26
    • /
    • 2022
  • Domestic district heating system needs safety management guidelines using the change of surface temperature to detect damages to buried heat pipes. This paper performed numerical analyses on the temperature change of ground surface due to the burial and leakage of heat pipes. Temperature difference between the ground surface above the buried heat pipes and the surrounding surface rises to a crescendo between 3 am and 8 am. It is more significant in winter rather than in summer. Low groundwater level magnifies the temperature increase of the ground surface by the heat pipe, which is smaller in the asphalt pavement than in the bare soil. Without leakage of the buried heat pipe, the temperature increment on the ground surface by the heat pipe is within 3.0℃ in the bare soil and 3.5℃ in the asphalt pavement. Leakage of the supply heat pipe in the bare soil increases the temperature on the ground surface gradually in the summer but rapidly in the winter. Asphalt pavement shows a lower increment and increasing rate of the temperature on the ground surface due to pipe leakage than bare soil surface. And leakage on both sides of the supply pipe takes 1-2 days for the temperature difference from the surrounding soil surface to reach 10℃.

On the Contact Behavior Analysis of an O-ring Seal using NBR and FFKM (NBR and FFKM O-링시일의 접촉거동 해석에 관한 연구)

  • 고영배;황준태;조승현;김청균
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.194-200
    • /
    • 2000
  • The sealing performance of an elastomeric O-ring seal using NBR and FFKM has been analyzed for the contact stress behaviors that develop between the O-ring seal and the surfaces with which it comes into contact. The leakage of an O-ring seal will occur when the pressure differential across the seal just exceeds the initial (or static) peak contact stress. The contact stress behaviors that develop in compressed O-rings, in common case of restrained geometry(grooved), are investigated using the finite element method. The analysis includes material hyperelasticity and axisymmetry. The computed FEM results show that the contact stress behaviors are related to materials of NBR and FFKM and temperature of vaccum chamber.

  • PDF

A Numerical Study on the Contact Behavior Analysis of Double Layer O-rings (이중 O링의 접촉거동 해석에 관한 수치적 연구)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • v.19 no.1
    • /
    • pp.9-14
    • /
    • 2003
  • The sealing performance of an elastomeric O-ring using the double layered material has been analyzed fer the contact stress behaviors that develop between the O-ring seal and the surfaces with which it comes into contact. The leakage of an O-ring will occur when the pressure differential across the seal Just exceeds the initial (or static) peak contact stress. The contact stress behaviors that develop in compressed O-rings, in common case of dovetail grooved geometry, are investigated using the finite element method. The FE analysis includes material hyperelasticity and axisymmetry. The computed FEM results show that the contact stress behaviors are related to the ratio of diameter between the inner ring and the outer ring, and the temperature of vacuum chamber.

Characteristic Analysis of a Magnet for Magnetically Levitated Vehicle using FLUX3D (FLUX3D를 이용한 자기부상용 전자석의 특성 해석)

  • Lee, Jae-Kun;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.127-129
    • /
    • 1996
  • A 3-dimensional analysis is desired for a magnet of magnetically levitated vehicle because the geometrical shape of the magnet is complicated and nonsymmetric. A FEM package of FLUX3D is used to analyze the characteristic of the magnet. Various quantities could be observed like levitation force, flux density distribution along the air gap, edge and fringing effect, leakage flux pattern, etc. The simulation results from FLUX3D are compared with those of 2-D analysis and test results. There are a little difference between results due to the boundary conditions and magnetized B-H curve of the core.

  • PDF

Characteristics Analysis of IPM Motor Considering Magnetic Saturation of Electrical Steel (IPM 모터 철심의 포화를 고려한 특성 해석)

  • Ha, Kyung-Ho;Ahn, Young-Jun;Na, Min-Su
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1031-1032
    • /
    • 2011
  • This paper deals with the characteristics analysis of Interior Permanent Magnet Type Motor varying with magnetization curve of electrical steel interpolated with several method in the high field region. The data of magnetization curve of electrical steel given by the steel maker is not enough in order to analysis the characteristics by menas of FEM. Especially, the core in the bridge part have a severe saturation because the bridge width is narrow to reduce the flux leakage produced by the permanent magnet. This paper make the three kinds of magnetization curve by extrapolation and then the motor is analyzed by using these magnetization curve. The motor parameters are compared to explain the effects of magnetization curve.

  • PDF