유한요소 LES법에 의한 축류 회전차 팁 틈새의 유동해석 (Flow Analysis in the Tip Clearance of Axial Flow Rotor Using Finite-Element Large-Eddy Simulation Method)

  • 이명호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.686-695
    • /
    • 2009
  • Flow characteristics in linear axial cascade have been studied using large eddy simulation(LES) based on finite element method(FEM) to investigate details of the leakage flow in the tip clearance of axial flow rotor. STAR-CD(FVM) and PAT-Flow(FEM) have been adopted to solve the Navier-Stokes equations for the simulation of the unsteady turbulent flow. Numerical results from the present study have been compared with the existing experimental results to investigate a tip clearance effect on velocity profile and static pressure distribution on blade surface at various spanwise positions. Both simulation results agree well with the experimental data. However, it has been shown that the results of finite-element large-eddy simulation agree better with experimental data than $k-{\varepsilon}$ turbulent model based on finite volume method regarding the tip vortex geometry and static pressure distribution at the center of the tip vortex core. As a result of this study, it is shown that finite-element large-eddy simulation method can predict more exactly on the tip leakage vortex flow and behind flow field.

누설자속탐상의 수치해석 (Numerical Analysis of Magnetic Flux Leakage Inspection)

  • 이향범;김신
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.485-492
    • /
    • 2001
  • 본 논문에서는 누설자속탐상에 대한 전자기 수치해석을 수행하였다. 수치해석방법으로 2차원 유한요소법을 이용하였다. 자기벡터포텐셜을 미지수호 사용하였으며, 자기비선형(磁氣非線型)을 고려한 자장해석을 수행하여 자기포화에 의한 영향을 고려하였다. 수치해석 결과를 검증하기 위하여 실험장치를 자체 제작하여 실험을 수행하였다 시료로는 SM 45C 탄소강을 사용하였으며, 표면에 몇 가지 결함을 생성하였다. 시편과 실험장치를 이용하여 결함을 검출하는 비파괴검사를 수행하였다. 결함의 깊이 변화 및 결함의 형상변화에 대하여 결과를 비교 검토하였다. 수치해석 및 실험에서 유사한 결과를 얻었으며, 수치해석을 통하여 누설자속탐상의 시뮬레이션이 가능함을 보였다.

  • PDF

소수력 터빈용 복수 기계평면시일의 접촉거동에 관한 유한요소해석 (Finite Element Analysis for the Contact Behavior in Double-Type Mechanical Face Seals Used for Small Hydro Power Turbine)

  • 김청균;강현준
    • Tribology and Lubricants
    • /
    • 제21권5호
    • /
    • pp.201-208
    • /
    • 2005
  • This paper presents the FEM analysis on the contact behavior characteristics of mechanical face seals in a small hydro-power turbine. Especially, the axial displacement and contact normal stress between a seal ring and a seal seat of a primary sealing unit have been analyzed as functions of rotating speed of a hydro-turbine, sealing gap, water and cooling fluid temperature. Those are strongly related to a leakage of water and wear between a seal ring and a seal seat. The FEM computed results present that the rotating speed of a hydro-turbine may be kept less than 800 rpm, and the sealing gap in a primary sealing unit is restricted $0.5\~5$. The coolant temperature in which is most influential parameter to the contact behaviors of a sealing unit may be kept less than $15^{\circ}C$ for a safe operation of a sealing unit without a leakage and wear.

제어-영구자석형 자기부상열차의 특성해석에 관한 연구 (The Study on the Characteristic Analysis of Controlled-PM LSM for Maglev Vehicle)

  • 이주;전연도;이관섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.450-457
    • /
    • 1998
  • Abstract - Linear Synchronous Motor has a large airgap comparing with rotary-type motor and especially, Permanent Magnet Linear Synchronous Motor(PM-LSM) which uses permanent magnet as a magnetic field, has a very large effective magnet airgap owing to permanent magnet structure. Accordingly, in case of 2-D analysis of the motor, the analysis error becomes large because leakage flux by which normal direction of the analysis region can not be considered, In this paper, the characteristic of PM-LSM for Maglev vehicle is analyzed exactly by 3-D Finite Element Method(3-D FEM). As the result, the effect of lateral-direction airgap magnetic flux density distribution on the analysis precision has been investigated and the motor characteristics according to primary motor parameter have been also made clear quantitatively. The accuracy of 3-D FEM has been confirmed by comparing the calculated results with the experimental results.

  • PDF

Design of Linear Transverse Flux Machine for Stelzer Machine using Equivalent Magnet Circuit and FEM

  • Jeong, Sung-In
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1596-1603
    • /
    • 2018
  • This paper presents the new design and validation process of the linear transverse flux machine of the stelzer machine for hybrid vehicle application. A linear transverse flux machine is a novel electric machine that has higher force density and power than conventional electric machine. The process concentrates on 2-dimensional and 3-dimensional analysis using equivalent magnetic circuit method considering leakage elements and it is verified by finite element analysis. Besides the force characteristics of all axis of each direction are analyzed. The study is considered by dividing the transverse flux electric excited type and the transverse flux permanent magnet excited type. Additionally three-dimensional analysis in this machine is accomplished due to asymmetric structure with another three axes. Finally, it suggests the new design and validation process of linear transverse flux machine for stelzer machine.

보정된 2차원 모델에 의한 초전도 교류 발전기의 과도특성 해석 (Analysis of Transient Characteristics in Superconducting AC Generator Using the Compensated 2-D Model)

  • 이형우;전연도;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.103-105
    • /
    • 1998
  • This paper presents the compensated 2-D magnetic fields analysis of superconducting AC generator(SCG) by using efficient 2-D model. 3-D analysis is necessary for the accurate analysis because SCG has a large leakage flux owing to the air cored winding and end ring structure. However, in 3-D FEM, considering the movement of rotor is difficult, so efficient 2-D model which can compensate the leakage flux has been proposed and the movement of rotor is easily considered. The characteristics in transient state of SCG and the prime role of damper also have been evaluated.

  • PDF

캘러킨 유한요소법을 이용한 미케니컬 페이스 시일의 윤활성능해석 (Lubrication Analysis of Mechanical Seal using Galerkin Finite Element Method)

  • 최병렬;이안성;최동훈
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.197-202
    • /
    • 1999
  • A mechanical face seal is a tribe-element intended to control the leakage of working fluid at the interface of a rotating shaft and its housing. The leakage of working fluid decreases as the seal surfaces get closer each other. But a very small seal clearance results in a drastic reduction of seal life because of high wear and heat generation. Therefore, in the design of mechanical face seals the compromise between low leakage and acceptable life is important and presents a difficult design problem. And the gap geometry of seal clearance affects seal performance very much and becomes an important design variable. In this study the Reynolds equation for the sealing dam of mechanical face seals is numerically analyzed using the Galerkin Finite Element Method, which can be readily applied to various seal geometries. The film pressures of the sealing dam are analyzed, including the effects of the seal face coning and tilt. Then, opening forces, restoring moments, leakages, and dynamic coefficients are calculated.

  • PDF

영구자석을 포함한 자기회로에서의 누설 자속 모델링 (Modeling of Flux Leakage in a Magnetic Circuit with Permanent Magnet)

  • 김승종;김우연;이종민;배용채
    • 한국소음진동공학회논문집
    • /
    • 제21권2호
    • /
    • pp.99-105
    • /
    • 2011
  • The magnetic circuit analysis excluding flux loss and fringing effect often gives a result with unignorable error, when compared with real system. But, it is not easy to make a complete magnetic circuit model with the loss effects. This paper introduces a relatively simple method to build the model including the flux loss and fringing effect, in which the paths of leaked flux are simplified in terms of circular arcs and straight lines. After modification of the model, the error of about 36 % in maximum between the magnetic circuit analysis and FEM analysis is reduced to about 7 %.

LPG 용기용 밸브의 체결안전성에 관한 유한요소해석 (FE Analysis on the Screwed Safety of a Valve for a LPG Bombe)

  • 김청균;오경석
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.79-84
    • /
    • 2007
  • LPG 용기에 장착된 네크링의 암나사와 개폐밸브의 수나사 사이에서 발생되는 접촉법선응력과 von Mises 응력을 유한요소법으로 해석하여 밸브나사의 체결안전성에 관련된 강도 및 가스누출 안전성에 대해 고찰하였다. LPG 봄베의 가스충전압력 $8{\sim}9kg/cm^2$은 밸브와 LP가스 용기의 체결작용과 밀봉작용을 담당하는 나사부에 가압된다. 나사 선단부에서 발생한 스크래치 마모나 칩핑 손상은 나사의 접촉높이를 실질적으로 낮추게 되어 나선부의 강도를 떨어뜨리고, LP가스의 누설을 조장하게 된다. 체결 나선부의 손상은 밸브 나사부의 이빨 강도를 약화시키고, LP가스의 누출에 영향을 미친다. FEM 해석결과에 의하면, 나사 선단부의 마모 및 칩핑에 의한 높이 손상은 이론적으로 볼 때 LP가스의 누출과 밸브의 강도에 영향을 미치지 못하는 것으로 나타났다. 그러나 황동밸브 나사 높이의 손상정도가 밸브의 임계강도를 넘어서게 되면, 나사는 밸브와 LP가스 봄베를 더 이상 체결하지 못하게 되어 압력용기는 갑자기 파손될 수도 있다.

  • PDF

과전류에 의한 TFR-8 케이블의 과도상태 특성에 관한 연구 (A Study on the Transient State Characteristics of TFR-8 Cable caused by Over Current)

  • 김병조;김재호
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.57-63
    • /
    • 2015
  • The incidence of fires caused by electrical factors has increased with the growth in domestic electrical consumption. According to the national fire data system of national emergency management agency, electrical fires accounted for 20% of all domestic fires in the last 10 years. Electrical fires are mainly caused by short circuit, leakage current, defect in an electrical equipment, over load, utility fault, etc. The fault current can be several times larger than the nominal current, thereby exceeding the rated current of cable. Consequently, the cable conductor, typically copper wire, heats up to a temperature that ignites surrounding combustibles. This paper describes the transient characteristics of the 0.6/1kV, TFR-8 cable have been investigated, and analyzed under the over current conditions for reduce the risk of electrical fire by experimental and FEM analysis. The experimental and FEM(Finite Element Method) analysis results of temperature and resistance variation according to the over current in copper wires were analyzed. The experimental results coincide well with the FEM analysis.