• 제목/요약/키워드: Leakage analysis FEM

검색결과 85건 처리시간 0.025초

토로이달 타입 플라이백 변압기의 누설 인덕턴스 해석 (Analysis of Leakage Inductance for Toroidal Type Flyback Transformer)

  • 박창수;강병극;신경구;정세교
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.164-172
    • /
    • 2014
  • This paper presents an analysis of a leakage inductance for a toroidal type flyback transformer. The equation to calculate the leakage inductance is derived using the MMF diagram of the transformer. The analysis for the different types of the cores and winding structures is also provided using the FEM simulation. The winding structures minimizing the leakage inductance are finally discussed from the simulation and experimental results.

On the Leakage Analysis of a Full Containment Tank Using a FEM

  • Kim, Chung-Kyun
    • KSTLE International Journal
    • /
    • 제7권2호
    • /
    • pp.45-50
    • /
    • 2006
  • In this paper, the leakage safety of prestressed concrete structure including the insulation panels has been analyzed using a finite element analysis just after a collapse of 9% nickel inner tank. This FEM study shows that the outer tank may contain the leaked cryogenic liquid for the time being until the primary pump in the inner tank transports stored cryogenic liquids to the nearest LNG storage tank before the outer tank is demolished. This means that the total tank thickness from the insulation panel to the outer tank system safely may retain the leaked cryogenic fluids. The FE computed results indicate that the current structure in a full containment tank is obviously enough to securing the leak-proof safety of the tank system with two primary pumps.

LPG 용기 밸브용 O-링의 누설안전성에 관한 해석적 연구 (Numerical Study on the Leakage Safety of O-rings for a LPG Cylinder Valve)

  • 김청균;김도현
    • 한국가스학회지
    • /
    • 제11권2호통권35호
    • /
    • pp.37-42
    • /
    • 2007
  • 본 논문에서는 밸브몸체와 밸브스템 사이의 사각그루브에 설치한 두 개의 O-링에 대한 누설 안전성을 해석한 결과를 제시하고 있다. O-링시일의 누설 안전성에 대한 해석은 압축률과 LPG 가스압력의 변동에 따라 발생되는 누설 안전성을 유한요소해석 프로그램 MARC로 계산하였다. FEM 해석결과에 따르면, LP가스 충전압력 $8kg/cm^2$에서 안전변의 안전한 작동압력 상한치 $24.8kg/cm^2$에 이르기까지 압력하중을 압력용기 안전기준에 의거 계산한 결과는 안전한 것으로 나타났다. 다만, 두 개의 O-링의 안전성을 충분하게 확보하기 위해서는 O-링소재의 시효경화 효과를 고려하는 것이 바람직하다.

  • PDF

소수력 터빈용 기계평면시일의 표면마찰형상에 따른 접촉특성 해석에관한 연구 (A Study on Contact Characteristics of Mechanical Face Seals for a Hydro-power Turbine Depending on the Rubbing Surface Geometry)

  • 김청균
    • Tribology and Lubricants
    • /
    • 제22권3호
    • /
    • pp.119-126
    • /
    • 2006
  • In this paper, the contact behavior characteristics of a primary sealing components such as a seal ring and a seal seat has been presented for a small hydro-power turbine. Using the non-linear FEM analysis, the maximum temperature, the axial displacement, radial differences between a seal ring and a seal seat, and maximum contact normal stress have been analyzed for three optimized sealing profiles in which are designed based on the FEM analysis and Taguchi's experimental method. The three primary sealing profiles between a seal ring and a seal seat are strongly related to a leakage of a water for a hydro-power turbine and wear of a primary sealing component. The computed results show that the contact rubbing area between a seal ring and a seal seat is very important for reducing a friction heating and wear in a sealing gap, and increasing a contact normal stress in primary sealing components. Based on the FEM computation, models II and III in which have a small rubbing surface of seal rings show low dilatation of primary sealing components, and high normal contact stress between a seal ring and a seal seat. Thus, the FEM computed results recommend a short contacting width of a primary sealing component for reducing a leakage and thermal distortions, and expanding a seal life. This means that a conventional primary sealing component may be switched to a reduced sealing face of seal rings.

손상된 흙댐 코어의 보수.보강을 위한 CGS 공법의 적용성 (Applicability of CGS for Remediation and Reinforcement of Damaged Earth Dam Core)

  • 천병식;최중근
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.325-334
    • /
    • 2003
  • 댐체 코어부에 발생한 수압파쇄와 이로 인한 유로의 발달 및 누수량 증대 등의 문제점을 구조적으로 차단하여 댐의 안정성을 확보하고, 장기적으로 댐을 유지관리 운영하는 데에 문제점이 없도록 댐 코어부를 보수.보강한다는 것은 쉬운 일이 아니다. 본 연구에서는 손상된 흙댐 코어의 보수.보강을 위한 CGS 공법(Compaction Grouting System)의 적용성을 천공과 주입과정에 대한 고찰과 그 결과에 대하여 검토하고, 현장에서의 계측치와 FEM 해석 결과의 비교.검토를 통하여 확인하였다. 현장 계측 결과, 공정이 진행되면서 선단 압력은 증가하고 주입량은 감소됨에 따라 느슨한 댐 코어의 공극이 채워진 것으로 나타났으며 동일 수위에 대하여 누수량 및 탁도는 보강 후의 누수량과 탁도가 모두 감소하였으며, FEM 해석 결과 역시 보강으로 인하여 투수계수가 감소하였다. 본 연구에서 CGS 공법을 통하여 기존 댐 코어재료 특성의 변화를 최소화하면서 느슨한 공극을 채워 투수계수와 누수량을 감소시켜서 댐 코어의 차수성을 향상시킬 수 있음을 확인하였다.

전차 선로용 폴리머 현수애자의 적용 기술 (Application Technologies of Polymer Suspended Insulators for the Electric Track Line)

  • 한세원;조한구;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.59-61
    • /
    • 2001
  • Polymeric suspended insulators for the electric track line have been developed. The main elements to design polymeric insulators are the insulation ability related with materials of FRP core and housing, and the optimal structure related with fitting parts and interface characteristics. To confirm the design fitness of insulator samples the electric field distribution by FEM and mechanical stress distribution by NASTRAN program was analysed with housing shed shapes and fitting structure. The leakage distance and breakage voltage properties which are core parameters to determine electric insulation ability are selected according to the requirement values of user specification, then the power frequency wet withstand voltage was specified above 22kV and the leakage distance was required above 290mm. The contamination condition of the electric track line was the heavy class according to IEC 815 in order to retain the enough safety margin against overvoltages.

  • PDF

누출사고 방지를 위한 위험물 탱크의 기초 안정성 분석 (Stability Analysis of the Foundation of Hazardous Material Storage Tank for Preventing Leakage Accidents)

  • 임종진;구재현
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.96-100
    • /
    • 2020
  • 산업단지내 위험물 저장탱크 기초의 결함으로 인한 위험물질의 유출사고는 인근 지역의 대형 인명사고 및 대형화재를 일으킬 수 있으므로 기초의 설계 및 시공단계에서 세심한 주의를 기울여야 한다. 본 연구에서는 기존 위험물탱크 단지가 건설된 대표지반을 선정하여 3차원 모델링에 의한 유한요소 수치해석을 수행하였으며, 위험물 저장탱크 기초의 안정성 평가를 위하여, 대표적인 탱크 기초 유형을 4종류로 분류하고 각 유형에 대한 해석을 수행하였다. 결과적으로, 탱크기초의 응력 및 침하량 크기와 분포 특성은 링월기초의 경우 옆판 직하부분이 탱크 중심부에 비해 40배 이상의 응력이 집중되는 경향을 보였으며, 침하영향범위는 수평방향으로 탱크 반경만큼, 수직방향으로 탱크 직경만큼으로 나타났다. 본 분석결과를 활용하여 각 기초 유형별로 위험물 저장탱크의 설계 및 품질관리 가이드라인을 제시하였다.

열저항 효과를 고려한 멤브레인식 LNG 저장탱크의 누설 안전성에 관한 연구 (On the Leakage Safety Analysis of Membrane LNG Storage Tank With Thermal Resistance Effects)

  • 김청균;조승현;서흥석;홍성호;이승림;김영규;권부길
    • 한국가스학회지
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2004
  • 본 연구에서는 멤브레인식 LNG 저장탱크의 누설 안전성을 목재와 PUF로 구성된 단열재 및 예응력 콘크리트(PC) 재질이 균일하다는 가정하에 열저항 평형온도 효과를 고려하여 유한요소법(FEM)으로 해석하였다. FEM 계산결과에 따르면, 목재와 PUF로 구성된 단열재 구조물은 누설 LNG에 의해 구조물 자체가 먼저 파손되므로 누설 안전성을 보장할 수 없다. 그러나, 내부탱크와 단열재가 동시에 파손되어도 외부탱크 PC 구조물은 강도 안전성을 확보하고 있으므로 누설 LNG를 최소 10일 정도는 안전하게 지연시킬 수 있어 멤브레인식 LNG 저장탱크 시스템의 누설 안전성은 확보될 수 있다.

  • PDF

FEM을 이용한 컨버터용 변압기 여자전류 및 와전류 손실해석 (Analysis of Converter Transformer Exiting Current and Eddy Loss by FEM)

  • 이정근;이곤;조익춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.750-751
    • /
    • 2008
  • 본 논문은 컨버터용 변압기의 여자전류 해석을 통해 DC 성분 유입시 자속밀도-여자전류 곡선 그래프를 도출하여 철심포화 여부를 확인하며, 철심 공극에 의해 발생되는 누설자속(Leakage Flux)으로 인한 철구조물(Lock Plate)의 와전류 손실을 계산하였다. 변압기 해석을 위해 상용 해석 소프트웨어인 Maxwell 3D를 이용하였고, 철심의 비선형성을 고려하여 해석하였다.

  • PDF

A COUPLED CFD-FEM ANALYSIS ON THE SAFETY INJECTION PIPING SUBJECTED TO THERMAL STRATIFICATION

  • Kim, Sun-Hye;Choi, Jae-Boong;Park, Jung-Soon;Choi, Young-Hwan;Lee, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.237-248
    • /
    • 2013
  • Thermal stratification has continuously caused several piping failures in nuclear power plants since the early 1980s. However, this critical thermal effect was not considered when the old nuclear power plants were designed. Therefore, it is urgent to evaluate this unexpected thermal effect on the structural integrity of piping systems. In this paper, the thermal effects of stratified flow in two different safety injection piping systems were investigated by using a coupled CFD-FE method. Since stratified flow is generally generated by turbulent penetration and/or valve leakage, thermal stress analyses as well as CFD analyses were carried out considering these two primary causes. Numerical results show that the most critical factor governing thermal stratification is valve leakage and that temperature distribution significantly changes according to the leakage path. In particular, in-leakage has a high possibility of causing considerable structural problems in RCS piping.