Browse > Article

On the Leakage Analysis of a Full Containment Tank Using a FEM  

Kim, Chung-Kyun (Department of Mechanical and System Design Engineering, Hongik University)
Publication Information
KSTLE International Journal / v.7, no.2, 2006 , pp. 45-50 More about this Journal
Abstract
In this paper, the leakage safety of prestressed concrete structure including the insulation panels has been analyzed using a finite element analysis just after a collapse of 9% nickel inner tank. This FEM study shows that the outer tank may contain the leaked cryogenic liquid for the time being until the primary pump in the inner tank transports stored cryogenic liquids to the nearest LNG storage tank before the outer tank is demolished. This means that the total tank thickness from the insulation panel to the outer tank system safely may retain the leaked cryogenic fluids. The FE computed results indicate that the current structure in a full containment tank is obviously enough to securing the leak-proof safety of the tank system with two primary pumps.
Keywords
Leakage analysis FEM; inner tank; outer tank; insulation panel;
Citations & Related Records
연도 인용수 순위
  • Reference
1 BS 7777: Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Part 1, pp. 9, 1993
2 Technical development and investigation report for LNG storage tank. Japanese Natural Gas Import Committee, pp. 158-159, March 1990
3 MARC user's manual. Ver. 6.3, MARC Analysis Research Co., 1996