• 제목/요약/키워드: Leakage Magnetic Flux Method

검색결과 90건 처리시간 0.023초

Optimum Design of a Non-Destructive Testing System to Maximize Magnetic Flux Leakage

  • Park, G.S;Jang, P.W;Rho, Y.W
    • Journal of Magnetics
    • /
    • 제6권1호
    • /
    • pp.31-35
    • /
    • 2001
  • This paper describes the design method of a magnetic system to maximize the magnetic flux leakage (MFL) in a non-destructive testing (NDT) system. The defect signals in a MFL type NDT system mainly depend on the change of the magnetic leakage flux in the region of a defect. The characteristics of the B-H curves are analysed and a design method to define the operating point on B-H curves for maximum leakage is performed. The computed MFL signal by a nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG, the traveling detector unit in gas pipe, in an 8 inch test tube with defects. The rhombic defects could be successfully identified from the defect signals.

  • PDF

Implementation of a Modified SQI for the Preprocessing of Magnetic Flux Leakage Signal

  • Oh, Bok-Jin;Choi, Doo-Hyun
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.357-360
    • /
    • 2013
  • A modified SQI method using magnetic leakage flux (MFL) signal for underground gas pipelines' defect detection and characterization is presented in this paper. Raw signals gathered using MFL signals include many unexpected noises and high frequency signals, uneven background signals, signals caused by real defects, etc. The MFL signals of defect free pipelines primarily consist of two kinds of signals, uneven low frequency signals and uncertain high frequency noises. Leakage flux signals caused by defects are added to the case of pipelines having defects. Even though the SQI (Self Quotient Image) is a useful tool to gradually remove the varying backgrounds as well as to characterize the defects, it uses the division and floating point operations. A modified SQI having low computational complexity without time-consuming division operations is presented in this paper. By using defects carved in real pipelines in the pipeline simulation facility (PSF) and real MFL data, the performance of the proposed method is compared with that of the original SQI.

Fatigue crack effect on magnetic flux leakage for A283 grade C steel

  • Ahmad, M.I.M.;Arifin, A.;Abdullah, S.;Jusoh, W.Z.W.;Singh, S.S.K.
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1549-1560
    • /
    • 2015
  • This paper presents the characterization of fatigue crack in the A283 Grade C steel using the MMM method by identifying the effects of magnetic flux leakage towards the crack growth rate, da/dN, and crack length. The previous and current research on the relation between MMM parameters and fatigue crack effect is still unclear and requires specific analysis to validate that. This method is considered to be a passive magnetic method among other Non-Destructive Testing (NDT) methods. The tension-tension fatigue test was conducted with a testing frequency of 10 Hz with 4 kN loaded, meanwhile the MMM response signals were captured using a MMM instrument. A correlation between the crack growth rate and magnetic flux leakage produces a sigmoid shape curve with a constant values which present the gradient, m value is in the ranges of 1.4357 to 4.0506, and the y-intercept, log C in the ranges of $4{\times}10^{-7}$ to 0.0303. Moreover, a linear relation was obtained between the crack length and magnetic flux leakage which present the R-Squared values is at 0.830 to 0.978. Therefore, MMM method has their own capability to investigate and characterize the fatigue crack effects as a main source of fracture mechanism for ferrous-based materials.

Optimum Design of the Non-Destructive Testing System to Maximize the Magnetic Flux Leakages

  • Park, G. S.;P. W. Jang;Park, Y. W.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2000년도 International Symposium on Magnetics The 2000 Fall Conference
    • /
    • pp.539-545
    • /
    • 2000
  • This paper describes the design method of the magnetic system to maximize the magnetic flux leakage (MFL) in non-destructive testing (NDT) system. The defect signals in MFL type NDT system mainly depends on the change of the magnetic leakage flux in the region of defect. The characteristics of the B-H curves are analyzed and the design method to define the operating point in B-H curves for the maximum leakage is performed. The computed MFL signal by nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG in the 8 inches test tube with defects. The rhombic defects could be successfully composed from the defect signals.

  • PDF

영구자석을 포함한 자기회로에서의 누설 자속 모델링 (Modeling of Flux Leakage in a Magnetic Circuit with Permanent Magnet)

  • 김승종;김우연;이종민;배용채
    • 한국소음진동공학회논문집
    • /
    • 제21권2호
    • /
    • pp.99-105
    • /
    • 2011
  • The magnetic circuit analysis excluding flux loss and fringing effect often gives a result with unignorable error, when compared with real system. But, it is not easy to make a complete magnetic circuit model with the loss effects. This paper introduces a relatively simple method to build the model including the flux loss and fringing effect, in which the paths of leaked flux are simplified in terms of circular arcs and straight lines. After modification of the model, the error of about 36 % in maximum between the magnetic circuit analysis and FEM analysis is reduced to about 7 %.

Design of Linear Transverse Flux Machine for Stelzer Machine using Equivalent Magnet Circuit and FEM

  • Jeong, Sung-In
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1596-1603
    • /
    • 2018
  • This paper presents the new design and validation process of the linear transverse flux machine of the stelzer machine for hybrid vehicle application. A linear transverse flux machine is a novel electric machine that has higher force density and power than conventional electric machine. The process concentrates on 2-dimensional and 3-dimensional analysis using equivalent magnetic circuit method considering leakage elements and it is verified by finite element analysis. Besides the force characteristics of all axis of each direction are analyzed. The study is considered by dividing the transverse flux electric excited type and the transverse flux permanent magnet excited type. Additionally three-dimensional analysis in this machine is accomplished due to asymmetric structure with another three axes. Finally, it suggests the new design and validation process of linear transverse flux machine for stelzer machine.

축방향 누설자속 측정에 의한 유도전동기의 회전자 결함검출에 관한 연구 (A Study of Rotor Fault Detection for the Induction Motor Using Axial Leakage Magnetic Flux)

  • 신대철;김영환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.132-137
    • /
    • 2006
  • 유도전동기에 대한 결함 검출의 도구로서 축방향 누설자속 측정 방법을 사용할 수 있는가를 평가하고 전동기고장 검출에 관한 진단 알고리즘을 개발하기 위한 회전자에 관한 2번째 논문이다. 결함 검출을 위해 운전 중인 전동기의 끝단에 설치된 자속코일 센서로 누설자속 신호를 수집하며 전동기의 각종 결함을 검출하기 위해 시간과 주파수 영역에서 신호를 분석하였다. 센서 신호 형상이 전동기 각각의 결함에 대해 시간과 주파수 영역에서 해석하였다. 전동기의 회전자 관련 격함인 회전자봉 파손, 단락환 파손 및 회전자 편심이 축방향에서 측정된 고해상도의 스펙트럼으로부터 검출할 수 있는 방법을 확인하였다. 누설자속 스펙트럼으로부터 특정 주파수와 회전자봉 통과주파수의 측파대를 분석함으로서 회전자 결함을 검출하는 방법을 알았다. 또 유도전동기에 대하여 축방향 누설자속 측정을 위한 최적의 자속코일센서 및 측정시스템을 검증하고 회전자 결함을 검출하기 위한 방법을 개발하였다.

Implementation of High Magnetization System for Performance Enhancement of Magnetic Flux Leakage Tool

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Kim, Dong-Ku;Park, Dae-Jin;Rho, Yong-Woo;Seo, Kang;Park, Gwan-Soo;Choi, Doo-Hyun;Song, Sung-Jin
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.199-203
    • /
    • 2010
  • This paper discusses the effectiveness of high magnetization saturation in ILI (In-Line Inspection) using an MFL (Magnetic Flux Leakage) tool, and introduces a practical method for improving the magnetization level together with the piggability. Thin steel plates, replacing the conventional wire brushes were used as conductors to transfer the magnetic flux to the pipe wall. The newly designed MFL tool was compared with the conventional version by means of FEM (Finite Element Method) analysis and full-scale experiments. In the results, the newly developed magnetization system obtained a stronger MFL signal amplitude, specially 2.7 times stronger, than that obtained by the conventional magnetization system for the same defect dimensions.

승강기 와이어로프 진단을 위한 누설자속기법 기반 국부손상 진단 (Magnetic Flux Leakage Method based Local Fault Detection for Inspection of Wire Rope)

  • 김주원;박주영;박승희
    • 한국전산구조공학회논문집
    • /
    • 제28권4호
    • /
    • pp.417-423
    • /
    • 2015
  • 본 연구에서는 와이어로프의 국부손상 검색을 위해 누설자속기법을 적용하였다. 와이어로프 구조물에 적용하기 위해 리프트오프의 발생을 최소화한 4채널 누설자속 센서헤드를 제작하였고, 이를 사용하여 와이어로프의 국부손상 검색실험을 수행하였다. 국부손상 검색실험을 위해 와이어로프를 준비하였고, 다양한 원주방향을 가지는 부분 단선 손상들을 발생시켰다. 제작된 자속누설 센서헤드를 이용하여 와이어로프 시편의 자속신호를 스캔하였고, 노이즈의 영향을 최소화하고 자속신호의 해상도를 향상시키고자 자속 신호를 미분하여 순간변화량을 손상 검색에 활용하였다. 객관적인 손상 판단을 위해 각 채널에서 계측된 자속신호를 GEV분포를 이용해 설정된 임계값과 비교하였다. 최종적으로 임계값을 초과한 부분의 길이방향 및 원주 방향 위치를 실제 손상과 비교함으로써 본 기법의 국부손상 검색 가능성을 살펴보았다.

강자성체 평판의 자속 누설 탐상 비파괴 실험 및 수치해석 (Non-destructive Testing and Numerical Analysis for Ferromagnetic Plates using Magnetic Flux Leakage Method)

  • 김신;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.126-128
    • /
    • 2001
  • In this paper, Magnetic Flux Leakage(MFL) method is used to detect surface defect in ferromagnetic plate. Surface defects are created on the SM 45C ferromagnetic plate and magnetizing equipment is composed to perform MFL nondestructive testing. The length and width of defect is twice the thickness of ferromagnetic plate, and defects with different depths are made artificially for the experiment. Also, NdFeB magnet in magnetizing equipment is used to make magnetic flux. This paper shows that it is possibile to detect 10% defect and to analyze numerically for any defect using MFL method.

  • PDF