• 제목/요약/키워드: Leakage Loss

검색결과 619건 처리시간 0.034초

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

DNN기반 상수도시스템 누수시나리오에 따른 누수탐지성능 평가 (Evaluation of leakage detection performance according to leakage scenarios of water distribution systems based on deep neural networks)

  • 김률;최영환
    • 한국수자원학회논문집
    • /
    • 제56권5호
    • /
    • pp.347-356
    • /
    • 2023
  • 상수도시스템에서는 적수 및 누수와 같은 다양한 수리 및 수질적 비정상상황이 발생한다. 이를 방지하거나 빠르게 복구하기 위하여 다양한 계측기에서 얻어지는 데이터를 통해 사고를 예상하고 탐지한다. 하지만 대표적인 수리학적 비정상상황인 누수의 경우 직접적인 탐사를 수행하지 않는다면 발견되기 어렵다. 그 중 미신고 파열누수의 경우 육안식별이 어렵기 때문에 가장 많은 누수를 차지하게 되며 이는 곧 큰 경제적 손실로 이어진다. 직접적인 탐사의 경우 전문인력 확보 등 현장의 여건 등 여러 한계점이 존재한다. 이를 해결하기 위해 본 연구에서는 검보정이 완료된 상수도관망 수리모형(EPANET)의 수리해석결과 데이터를 학습데이터로 사용하고 Deep neural network 알고리즘을 활용하여 누수규모 및 누수위치에 대한 누수탐사를 수행하였다. 누수탐사 수행을 위해 모의 누수 사고데이터를 생성하였으며 누수규모, 위치 등 다양한 시나리오를 고려하였다. 또한, 최적의 누수 탐지 성능을 위해 관망의 크기, 계측기의 종류, 개수, 위치에 따른 탐지성능을 분석하였다.

ZnO 피뢰기 소자에 흐르는 누설전류의 주파수의존성 (Frequency Dependences of leakage currents flowing through ZnO surge arrester block)

  • 이복희;이봉;강성만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.303-306
    • /
    • 2005
  • This paper presents the frequency-dependent characteristics of leakage currents flowing through ZnO surge arrester block. The leakage current-voltage (I-V) characteristic curves of the commercial ZnO surge arrester blocks were measured. The resistive leakage current was found to increase with increasing frequency in the low conduction region. The capacitance of ZnO block was independent of the magnitude and frequency of the applied voltage. The power losses of ZnO block increase as the frequency of applied voltage increases, because of the dielectric loss related to the frequency of the test voltage.

  • PDF

고주파 유도가열용 전원장치의 개발에 관한 연구 (A Study on Development of Power Supply for High Frequency Induction Heating)

  • 이봉섭
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.179-186
    • /
    • 2002
  • This paper proposed LC resonant current fed high frequency inverter for high frequency induction heating using leakage inductance of transformer and, its described operating principle. The analysis of circuit presented by using normalized parameter in considering leakage inductance of transformer and, discussed characteristic evaluation of inverter circuit in detail. The proposed inverter is operating ZVS to reduce turn-on and turn-off loss of switching devices so, raised an efficiency. And, the experimental apparatus was made on base characteristic evaluation of theoretical analysis to discuss possibility on high frequency source and confirmed a rightfulness theoretical analysis. A result of study, the proposed inverter is higher utilizing factor using on leakage inductance of transformer and show possibility, which is application on high frequency power system.

  • PDF

임베디드 시스템을 이용한 빌딩 누전감시 시스템 (A Leakage Current Supervising Control and Data Acquision in the Building based on Embedded System)

  • 신승우;유종일;장경배;심일주;박귀태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2457-2460
    • /
    • 2004
  • As the usage of electron electricity is rapidly increasing, corresponding accidents also take place proportionately. Although various losses occur very often because of senility of system and maintenance, only a earth leakage current breaker by a leakage current alert is used. That means it is always fraught with dander. This paper, we propose to measure and cut a leakage current and method of taking a measurement current short circuit. Besides, through keeping watch communication with server, prevent electric loss and mishap in advance.

  • PDF

ZnO 바리스터에 흐르는 누설전류의 주파수 의존성 (Frequency dependences of leakage currents flowing through ZnO varistor)

  • 이복희;이봉;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2166-2168
    • /
    • 2005
  • This paper presents the frequency - dependent characteristics of leakage currents flowing through ZnO varistor. The leakage current - voltage (V-I) characteristic curves of the commercial ZnO varistor were measured. The resistive leakage current was increased with increasing the magnitude and frequency of the applied voltage in the low conduction region. The power losses of ZnO varistor increase as the frequency of applied voltage increases, because of the dielectric loss related to the frequency of the test voltage.

  • PDF

상수도 관망의 유수율 제고 기술의 적용 및 분석 (Technical Application and Analysis for Reduction of Water Loss in Water Distribution Systems)

  • 김주환;이두진;배철호;우형민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.260-266
    • /
    • 2009
  • 본 연구는 지방상수도 배급수 관망의 유수율을 향상시키기 위하여 수량관리를 위한 블록시스템 구축을 통한 구역화 계량, 누수의 정량화를 위한 야간최소유량 측정을 통한 누수평가지표 및 국제 누수지수ILI(Infrastructure Leakage Index)의 도입, 압력제어를 통한 누수저감 효과분석, 장기적인 계획수립을 위하여 노후수도관의 잔존수명 예측 등 누수를 평가 관리할 수 있는 기술을 개발, 제안하였다. N시 야간최소유량 측정을 통하여 주거지역과 상업지역에서 정량적인 누수평가지표로 관길이당, 급수전당의 허용기준누수량을 산정하였다. 이는 관망정비가 완료된 주거, 상업지역을 각각 대상으로 UK water industry에서 제안한 방법을 이용하여 실측을 통한 야간최소유량을 분석함으로써 유수율을 대신할 수 있는 허용누수량 산정식을 개발하였다. 압력제어를 통한 누수저감효과는 감압변의 설치를 통하여 수행되는데, 사천시 우티 배수구역을 대상으로 압력관리 구역을 4개로 분할하고 감압밸브 3개소, 가압펌프 1개소를 설치하여 압력을 조절한 결과 약 $466\;m^3/day$의 누수를 저감시킬 수 있을 것으로 나타나 압력관리를 통하여 연간 113백만의 비용절감효과가 기대되었다. 노후 상수관로의 부식속도 및 잔존수명 예측 연구에서는 매설년도, 토양 또는 수질특성에 따른 관체의 부식속도를 평가함으로써 잔존두께를 예측할 수 있는 모델을 개발하였으며 또한 부식으로 인한 공식특성에 따른 잔존강도 등을 평가할 수 있는 비선형회귀 모형을 개발, 수도관의 잔존수명예측에 활용하여 장단기 노후관 개대체 계획수립에 활용할 수 있도록 제안하였다. 본 연구의 결과들은 지방상수도의 유수율 제고 및 관망정비사업에 적극적으로 활용할 수 있는 누수평가 및 관리기법을 제안할 수 있을 것으로 기대된다.

  • PDF

개인정보유출 2차 피해로 인한 스마트폰 Smishing 해킹과 Forensic 연구 (A Study on SmartPhone Hacking and Forensic of Secondary Damage caused by Leakage of Personal Information)

  • 박인우;박대우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.273-276
    • /
    • 2014
  • 2014년 카드3사의 개인정보유출로 약 1건의 고객정보가 유출되었다. 카드사는 개인정보유출로 인한 2차 피해는 없다고 단정지었지만, 실제로 개인정보유출 2차 피해가 발생하고 있다. 특히 스마트폰에서 Smishing은 유출된 개인정보를 이용하여 지인을 가장한 송금과 소치올림픽 김모양 소송, 차량단속대상적발 등 개인정보 유출로 인한 2차피해가 스마트폰에서 Smishing사고가 발생하고 있다. 본 논문에서는 스마트폰 Smishing사고에 대한 개인정보유출에 대한 Forensic 하고 스미싱 사고로 인한 금융피해에 대한 Forensic을 분석 하고자 한다.

  • PDF

내부정보유출방지를 위한 DLP시스템 연구 (A Study on DLP System for Preventing Internal Information Leakage)

  • 유승재
    • 융합보안논문지
    • /
    • 제18권5_1호
    • /
    • pp.121-126
    • /
    • 2018
  • 현대의 정보통신 기술과 네트워크 기술이 발달은 기업의 운영환경을 스마트하게 변화시켰으며, 그 가운데서 수많은 데이터들이 생성되고 저장되고 사용되고 있다. 기업경영의 에너지원이 되는 중요한 정보는 경제적인 이윤과 가치를 생성하고 또한 강력한 영향력의 근거로 활용된다. 따라서 주요정보는 그 가용성과 편의성을 확보해야 함과 동시에 기밀성과 무결성을 담보해야 하는 것이며 이것이 바로 정보보호의 기본목표가 된다고 할 수 있다. 그러나 대부분의 기업들은 중요한 내부정보가 유출되어 심각한 피해를 야기하는 사고가 증가하고 있다. 이에 본 연구에서는 내부정보유출을 방지하고 안정적인 데이터보안 및 정보보호관리 구축을 위한 DLP(Data Loss Prevention) 기술과 솔루션에 대해 살펴본다.

  • PDF

고주파 트랜스포머의 권선배열에 기법 따른 손실해석 (Power Loss Analysis according to Winding Array Method of High Frequency Transformer)

  • 윤신용;김일남
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.