• Title/Summary/Keyword: Leakage Flux

Search Result 313, Processing Time 0.038 seconds

Numerical Analysis of Magnetic Flux Leakage Inspection (누설자속탐상의 수치해석)

  • Lee, Hyang-Beom;Kim, Sean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.485-492
    • /
    • 2001
  • In this paper, electro-magnetic numerical analysis of MFL(magnetic flux leakage) method is presented. For the electromagnetic numerical analysis, 2-D FEM(finite element method) is used. The magnetic vector potential is used as a variable. The analysis of the magnetic field considering the magnetic nonlinearity is performed for the effect of the magnetic salutation. For the verification of the validity of the numerical simulation results, by using the lab-made experimental setup, non-destructive inspection is performed. The SM 45C carbon steel is used as a specimen and the artificial defects are made on the specimen. The non-destructive testing for the detection of the defect is performed. The results according to the variation oi the defect depth and the defect shape are obtained. The experimental results are compared to the numerical ones, and we conclude that the numerical results are similar to the experimental ones. So the possibility of simulation of the MFL by using the numerical analysis is shown in this paper.

  • PDF

Research on MFL PIG Design for caustic and defect the Inspection of Underground Gas Pipeline (지하매설 가스관의 부식 및 결함 탐지를 위한 비파괴 누설 탐상시스템 개발에 관한 연구)

  • Park, Sang-Ho;Park, Gwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.11-20
    • /
    • 2002
  • This paper describes the magnetic flux leakage(MFL) type non-destructive testing(NDT) system to detect the 3D defects on underground gas pipe. Magnetic systems with permanent magnets and yokes are analyzed by 3D non-lineal finite element method(FEM) with optimum design. In case of under-saturation of gas pipe, sensing signals are too weak to detect. In case of over-saturation, the changes of the sensing signals are too low to detect the defects sensitively. So, the operating points of the magnetic system are optimized to increase the changes of the MFL signals. The effects of the depth and size of the defects on the sensing signals are analyzed to define the range and resolution of the MFL sensors. To increase the sensor's sensitivity, the back-yoke sensors are introduced and tested.

  • PDF

Development of On line Diagnosis System for Generator (발전기 운전중 종합 진단시스템 개발)

  • Lee, Young-Jun;Kong, Tae-Sik;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.975-977
    • /
    • 2005
  • The generator on-line diagnosis system has been developed. This system monitor the insulation condition of stator winding by on-line measurements of partial discharge and the shorted-turn condition of rotor winding by on-line measurements of slot leakage flux. Sensor, such as SSC(Stator Slot Coupler) and flux probe are used for generator on-line diagnosis.

  • PDF

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF MARGINAL LEAKAGE USING A RADIOACTIVITY (충전후 방사능에 의한 변연누출 측정에 관한 실험적 연구)

  • Kim, Mi-Ja;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.69-78
    • /
    • 1988
  • The study was designed to establish a more nearly quantitative method for assessing the marginal leakage of dental restorations. 27 Class V cavities with $45^{\circ}$ bevel joint were prepared and classified into 2 groups. One group was filled with Scotchbond and silux. The other group was filled with glass ionomer cement, Scotchbond and silux. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ water-bath. They were soaked in a samarium nitrate solution for 3 hours, irradiated with flux of $6{\times}10^{12}$ neutrons/$cm^2$/sec for 11 hours, cooled for 200 hours, counted with the HPGE detector and the tracer uptake was determined by comparison with a standard of samarium (10 ${\mu}g$). The following results were obtained. 1. Both of the two groups showed a considerable amounts of marginal leakage. 2. The group filled without glass ionomer cement base showed more marginal leakage than the group filled with glass ionomer cement base. 3. Neutron Activation Analysis produced a good quantitative method to measure the marginal leakage and samarium was appropriate to measure the marginal leakage of resin restorations using neutron activation analysis.

  • PDF

On-Line Detection of Shorted Turn in Generator Rotor Windings (발전기 회전자 권선의 운전중 층간단락 탐지)

  • Kim, Hui-Dong;Lee, Yeong-Jun;Park, Jong-Jeong;Ju, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.192-199
    • /
    • 1999
  • During start up and shut down, the generator is rotating at a low speed and copper dusts cause arcing between the turns in the slot. Shorted turns occurred primarily by the movement of these copper dusts between individual windings in the generator rotor. Detection of shorted turns was performed in five gas turbine generators in two combined cycle power plants. Two types of permanent and temporary flux probes were used in this paper. These flux probes have been used to develop a methodology for detecting shorted turns in an operating generator's rotor. The flux probes sense the rotor winding slot leakage flux and produce a voltage proportional to the rate of change of the flux. This pattern of flux variation is the signature unique to each rotor winding. An appropriate waveform analysis technique canidentify the pole location, the slot number, and the number of shorted turns within each slot. Shorted turns in field winding of gas turbine generator(125.7 MVA) were detected to twelve turns on al total 190 turns.

  • PDF

An Approximate Determination of the Adjoint Flux by the Borresen's Coarse-Mesh Method (Borresen의 소격해법에 의한Adjoint속의 근사적 결정)

  • Kim, Chang-Hyo
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.56-61
    • /
    • 1989
  • A simple, approximate method for determining the two-group adjoint flux based on the Borresen's coarse-mesh 1.5 group diffusion theory scheme is proposed. With the principle of the 1.5 group diffusion theory scheme, the method describes the thermal leakage term of the adjoint flux approximately by the geomerical buckling determined from the fast adjoint flux. The accuracy of the adjoint flux is investigated tv the comparison of the adjoint flux constructed from this method with a fine-mesh finite-difference KIDD computations. It is shown that the proposed method can predict the adjoint flux as good as the KIDD results. Possible applications of the present method are then suggested in conjunction with the application of the perturbation theory.

  • PDF

A Study on Transverse Edge Effect in Linear Induction Motor With Sheet Rotor (Sheet Rotor를 가진 직선형 유도전동기의 Transverse Edge Effect에 관한 연구)

  • Yun Jong Lee;Dal Ho Im;Soo Hyun Baek
    • 전기의세계
    • /
    • v.23 no.4
    • /
    • pp.39-45
    • /
    • 1974
  • In most previous research work, the transverse edge effect has been allowed for only by use of a relativity-increase factor. This paper gives a more exact treatment. A two-dimensional-field analysis is presented for the problem of sheet rotor linear induction motor with finite width the method used takes account of flux leakage in the space between the stator and secondary sheet rotor as well as in the secondary itself. Equations are derived for the flux density distribution in the air gap and for the starting face, in each case as a function of stator current. The cross gap flux density peaks towards athe edge of the stator. This phenomena is known as the transverse edge effect. Measurements of the flux density in the air gap and starting force on a linear induction motor with sheet rotor of different width showed a reasonable agreement,suggest that it would be desirable to take into account also, at least for this motor in which severe redistribution occurs.

  • PDF

Srability Analysis Of High-Tc Superconducting Tape Through Magnetic Field Analysis Of The High-Tc Superconducting synchronous Motor (고온초전도동기모터의 자계분포해석에 따른 테이프선재의 안정도해석)

  • 송명곤;윤용수;홍계원;이산진;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.25-29
    • /
    • 1999
  • The purpose of this paper is to find the magnetic filed distribution inside the motor in order to find out if the high-Tc superconducting tapes operate stably in actual motor operation in a detailed model of the actual motor was analyzed through F.E.M.(finite Element Method). As a result, it has been proved that the high-Tc superconducting tapes can with-stand 4 A of current with staility. 4 A was the amount of current with stability. 4 A was the amount of current needed to achieve 600 A·turns which is required by the previous simulation aimed at developing this the flux damper reduces armature reactance during the motor operation. But it was observed that the flux damper generates loss by means of leakage flux and this decreases the output of the motor by about 5%.

  • PDF

A Study on the Iron Loss and Demagnetization Characteristics of an Inset-type Flux-Reversal Machine

  • Kim, Tae Heoung
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.297-301
    • /
    • 2013
  • Flux-reversal machine (FRM) is cost effective and suitable for mass production due to its simple structure. However, there is a notable permanent magnet flux leakage which deteriorates the performance. To compensate this drawback with a design method, an Inset-Permanent-Magnet-Type FRM (ITFRM) has been proposed. The ITFRM has permanent magnets perpendicular to the stator teeth surface, and thus, is much more difficult to demagnetize. In this paper, we deal with the iron losses and irreversible permanent magnet demagnetization characteristics of the ITFRM according to various design variables and driving conditions. To analyze the characteristics, a two-dimensional finite-element method (2D-FEM) considering nonlinear analysis of permanent magnets is used. As a result, we propose the design variables that have the largest effects on the iron losses and irreversible magnet demagnetization.

Analysis on the Levitation Force Characteristics of Longitudinal Flux Type Levitation Magnet using Equivalent Magnetic Circuit Model (등가자기회로 모델을 이용한 종자속형 자기부상 전자석의 부상력 특성 해석)

  • Cho, Han-Wook;Kim, Chang-Hyun;Lee, Jong-Min;Han, Hyung-Suk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2236-2245
    • /
    • 2011
  • This paper deals with the levitation force characteristics of electromagnet for MAGLEV vehicle application. The magnetic flux density distribution and levitation force characteristics of the electromagnet are investigated by means of equivalent magnetic circuit model. Firstly, we defined the aligned and unaligned electromagnet module for the full-electromagnet, and magnetic flux paths are represented for each model including leakage and fringing flux paths. Because of the analysis model contains both the permanent magnet and electromagnet coil, we calculated the airgap magnetic flux density and levitation forces using flux superposition in electromagnetic circuit. The results are validated extensively by comparison with finite element analysis. Moreover, the 1/4 scaled magnetic levitation and propulsion test vehicle has been manufactured and tested in order to verify these predictions. The experimental results confirms the validity of the analytical prediction with equivalent magnetic circuit model for the description of a electromagnet.