• Title/Summary/Keyword: Leakage Flow Rate

Search Result 269, Processing Time 0.047 seconds

Water Balance Analysis of Pumped-Storage Reservoir during Non-Irrigation Period for Recurrent Irrigation Water Management (순환형 농업용수관리를 위한 농업용 저수지의 비관개기 양수저류 추정)

  • Bang, Na-Kyoung;Nam, Won-Ho;Shin, Ji-Hyeon;Kim, Han-Joong;Kang, Ku;Baek, Seung-Chool;Lee, Kwang-Ya
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.1-12
    • /
    • 2020
  • The extreme 2017 spring drought affected a large portion of South Korea in the Southern Gyeonggi-do and Chungcheongnam-do districts. This drought event was one of the climatologically driest spring seasons over the 1961-2016 period of record. It was characterized by exceptionally low reservoir water levels, with the average water level being 36% lower over most of western South Korea. In this study, we consider drought response methods to alleviate the shortage of agricultural water in times of drought. It could be to store water from a stream into a reservoir. There is a cyclical method for reusing water supplied from a reservoir into streams through drainage. We intended to present a decision-making plan for water supply based on the calculation of the quantity of water supply and leakage. We compared the rainfall-runoff equation with the TANK model, which is a long-term run-off model. Estimations of reservoir inflow during non-irrigation seasons applied to the Madun, Daesa, and Pungjeon reservoirs. We applied the run-off flow to the last 30 years of rainfall data to estimate reservoir storage. We calculated the available water in the river during the non-irrigation season. The daily average inflow from 2003 to 2018 was calculated from October to April. Simulation results show that an average of 67,000 tons of water is obtained during the non-irrigation season. The report shows that about 53,000 tons of water are available except during the winter season from December to February. The Madun Reservoir began in early October with a 10 percent storage rate. In the starting ratio, a simulated rate of 4 K, 6 K, and 8 K tons is predicted to be 44%, 50%, and 60%. We can estimate the amount of water needed and the timing of water pump operations during the non-irrigation season that focuses on fresh water reservoirs and improve decision making for efficient water supplies.

Allyl-isothiocyanate Content and Physiological Responses of Wasabia japonica Matusum as Affected by Different EC Levels in Hydroponics (고추냉이 수경재배시 배양액의 EC 수준이 Allyl-isothiocyanate 함량과 생리적 반응에 미치는 영향)

  • Choi, Ki-Young;Lee, Yong-Beom;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.29 no.4
    • /
    • pp.311-316
    • /
    • 2011
  • This study aimed to determine the effect of EC (electrical conductivity) levels of nutrient solution in hydroponic culture on allyl-isothiocyanate (AITC) content within plant tissues, Vitamin C content and physiological responses in wasabi plant (Wasabia japonica M. 'Darma'). The 'Darma' was grown for 5 weeks with a deep flow technique (DFT) system controlled at 5 different EC levels, including 0.5, 1, 2, 3, and $5dS{\cdot}m^{-1}$. In result, the highest total content of AITC showed at EC level 5 and $3dS{\cdot}m^{-1}$ for 1 or 5- week, respectively. The total content of AITC increased about 1.2-1.4 times when the plants were grown in the EC levels between 0.5 and $2dS{\cdot}m^{-1}$, whereas the content decreased about 6 and 56 % in the EC level 3 and $5dS{\cdot}m^{-1}$, respectively. The content of AITC was relatively higher in petiole tissue, about 53 %, taken from 1 week-grown plants when the EC was controlled between 0.5 and $2dS{\cdot}m^{-1}$. Root tissue also had relatively higher content of AITC, about 45.1 %, when the EC was controlled at 3 and $5dS{\cdot}m^{-1}$. However, a 5-fold decrease in the AITC content was found in blade tissue and a 6.8-fold decrease in root when the EC was controlled at $5dS{\cdot}m^{-1}$ for 5 weeks. There was no significant difference in the vitamin C content in 1-week grown leaf tissues under the different EC level treatments; but, the content increased about 27% in 5-week grown plants at the EC level between 0.5 and $2dS{\cdot}m^{-1}$, compared to the 1 week-grown leaf tissue. Electrolyte leakage of leaf tissue taken from 3-week grown plant was 3-fold higher at the EC level $5dS{\cdot}m^{-1}$, compared to the EC level between 0.5 and $2dS{\cdot}m^{-1}$. Chlorophyll content, photosynthesis rate and transpiration rate were decreased when the EC was controlled at higher than $2dS{\cdot}m^{-1}$. Leaf water content, specific leaf area and growth were decreased when the EC was controlled at $5dS{\cdot}m^{-1}$ for 5 weeks. All the integrated results in this study suggest that the EC level of nutrient solution should be maintained at lower than $3dS{\cdot}m^{-1}$ in order to improve nutritional value and quantity required for hydroponically grown wasabi as functional vegetable.

The Electrochemical Characteristics of Hybrid Capacitor Prepared by Chemical Activation of NaOH (NaOH 화학적 활성화로 제조된 하이브리드 커패시터의 전기화학적 특성)

  • Choi, Jeong Eun;Bae, Ga Yeong;Yang, Jeong Min;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.308-312
    • /
    • 2013
  • Active carbons with high specific surface area and micro pore structure were prepared from the coconut shell char using the chemical activation method of NaOH. The preparation process has been optimized through the analysis of experimental variables such as activating chemical agents to char ratio and the flow rate of gas during carbonization. The active carbons with the surface area (2,481 $m^2/g$) and mean pore size (2.32 nm) were obtained by chemical activation with NaOH. The electrochemical performances of hybrid capacitor were investigated using $LiMn_2O_4$, $LiCoO_2$ as the positive electrode and prepared active carbon as the negative electrode. The electrochemical behaviors of hybrid capacitor using organic electrolytes ($LiPF_6$, $TEABF_4$) were characterized by constant current charge/discharge, cyclic voltammetry, cycle and leakage tests. The hybrid capacitor using $LiMn_2O_4$/AC electrodes had better capacitance than other hybrid systems and was able to deliver a specific energy as high as 131 Wh/kg at a specific power of 1,448 W/kg.

The Development of High Pressure Long Distance Fire-fighting Hose with Phosphorescent Performance (축광 성능을 갖는 고압용 장거리 호스 개발에 관한 연구)

  • Han, Yong-Taek;Na, Byung-Gyun;Choi, Jin-Seong;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.63-69
    • /
    • 2017
  • This study describes the development of a long-distance hose for ultra-high pressure operation, which can be used in conjunction with an ultra-high pressure pump and can be effectively applied to the fire suppression of high-rise buildings and a long, large tunnels. Also, it has phosphorescent properties, which can help to secure the withdrawal route of the fire-fighters when they are threatened by the fire. We developed an ultra-high pressure hose aiming at a pressure of 3 MPa and a flow rate of 2000 lpm and developed an ultra-high pressure fire hose that can withstand this very high pressure by using a double jacket, triple polyurethane coating and warf (Wp) of 52. In order to ensure the performance of the developed ultra-high pressure hose, its structure, appearance, leakage at high pressure, length and elongation were inspected by a certified certification agency, who also subjected it to a peeling test, friction test, breaking pressure test and free fall test. Also, it was studied in addition to the luminescent high-pressure hose for fire-fighting. In the phosphorescence test, the luminance measurement value was more than the reference value of the luminance test after 40 minutes, which confirmed that its performance was satisfactory for fire-fighting products. In the future, if such an ultra-high pressure fire hose were commercialized and applied in the field, it could contribute to securing improved fire suppression and safer exit from fires, as compared to the fire hoses currently used in the suppression of fires in skyscraper buildings and long tunnels.

Assessment of the level and identification of airborne molds by the type of water damage in housing in Korea (국내 주택에서 물 피해 유형에 따른 부유곰팡이 농도 수준 평가 및 동정 분석)

  • Lee, Ju Yeong;Hwang, Eun Seol;Lee, Jeong-Sub;Kwon, Myunghee;Chung, Hyen Mi;Seo, SungChul
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.355-361
    • /
    • 2018
  • Mold grows more easily when humidity is higher in indoor spaces, and as such is found more often on wetted areas in housing such as walls, toilets, kitchens, and poorly managed spaces. However, there have been few studies that have specifically assessed the level of mold in the indoor spaces of water-damaged housing in the Republic of Korea. We investigated the levels of airborne mold according to the characteristics of water damage types and explored the correlation between the distribution of mold genera and the characteristics of households. Samplings were performed from January 2016 to June 2018 in 97 housing units with water leakage or condensation, or a history of flooding, and in 61 general housing units in the metropolitan and Busan area, respectively. Airborne mold was collected on MEA (Malt extract agar) at flow rate of 100 L/min for 1 min. After collection, the samples were incubated at $25^{\circ}C$ for 120 hours. The cultured samples were counted and corrected using a positive hole conversion table. The samples were then analyzed by single colony culture, DNA extraction, gene amplification, and sequencing. By type of housing, concentrations of airborne mold were highest in flooded housing, followed by water-leaked or highly condensed housings, and then general housing. In more than 50% of water-damaged housing, the level of airborne mold exceeded the guideline of Korea's Ministry of Environment ($500CFU/m^3$). Of particular concern was the fact that the I/O ratio of water-damaged housing was greater than 1, which could indicate that mold damage may occur indoors. The distribution patterns of the fungal species were as follows: Penicillium spp., Cladosporium spp. (14%), Aspergillus spp. (13%) and Alternaria spp. (3%), but significant differences of their levels in indoor spaces were not found. Our findings indicate that high levels of mold damage were found in housing with water damage, and Aspergillus flavus and Penicillium brevicompactum were more dominant in housing with high water activity. Comprehensive management of flooded or water-damaged housing is necessary to reduce fungal exposure.

Effect of Viscosity and Clogging on Grout Penetration Characteristics (점도 변화와 폐색 현상을 고려한 그라우트재의 침투 특성)

  • Kim, Jong-Sun;Choi, Yong-Ki;Park, Jong-Ho;Woo, Sang-Baik;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.5-13
    • /
    • 2007
  • Many construction projects adopt grouting technology to prevent the leakage of groundwater or to improve the shear strength of the ground. Recognition as a feasible field procedure dates back to 1925. Since then, developments and field use have increased rapidly. According to improvement of grout materials, theoretical study on grout penetration characteristics is demanded. Fluid of grout always tends to flow from higher hydraulic potential to lower one and the motion of grout is also a function of formation permeability. Viscosity of pout is changed by chemical action while grout moves through pores. Due to the increment of viscosity, permeability is decreased. Permeability is also reduced by grout particle deposits to the soil aggregates. In this paper, characteristics of new cement grout material that has been developed recently are studied: injectable volume of new grout material is tested in two different grain sizes of sands; and the method to calculate injectable volume of grout Is suggested with consideration of change in viscosity and clogging phenomena. The calculated values are compared with injection test results. Viscosity of new grout material is found to increase as an exponential function of time. And lumped parameter $\delta$ of new grout material to be used for assessing deposition characteristics is estimated by comparing deposit theory with injection test results considering different soil types and different injection pressures. Injection test results show that grout penetration rate is decreased by the increase of grout viscosity and clogging phenomena.

Influences of Histamine on Permeability across Blood-brain Barrier (혈액-뇌장벽 투과성에 대한 히스타민의 영향)

  • Kim, Kee-Jin;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.33-43
    • /
    • 1968
  • Histamine, 0.5 mg as histamine base in 4 ml of normal saline solution, was injected into rabbits anesthetized with nembutal and the mean blood pressure was kept in the range of $52{\sim}80\;mmHg$ for over one hour by supplemental additions. Following the injection of the test substances, 300 mg of urea and 200 mg of antipyrine intravenously, serial blood samples were obtained from the femoral artery and the internal jugular vein at $0.5{\sim}3$ minutes interval. The decreasing patterns in the concentrations of arterial and venous blood plasma samples were compared with each other. The ratio of the concentration of brain tissue to that of the final arterial plasma was also studied. By these measures the degrees of penetration of the test substances in the brain in the control and in the histamine treated rabbits were observed. The concentrations of antipyrine and urea in the arterial blood plasma were decreasing exponentially with respect to the time elapsed. The venous concentrations were anticipated to increase initially and to cross the arterial concentration curve in the point of equlibrium between the plasma and the tissue. On the contrary to the expectation venous concentration also revealed the decreasing tendency similar to that of arterial plasma. The similarity between these two curves, arterial and venous, would be atributable to the fact that the cerebral blood flow rate was large enough and the rising phase in the venous concentration curve was instantly over before serial blood samples were taken. Inspite of some similarity in the decreasing tedency in both concentration curves there were appreciable discrepancies between the arterial and venous plasma which would reflect the situation far from the equlibria among several compartments in the brain. Changes in plasma potassium levels caused by the injection of histamine or bleeding were observed, too. Using 8 rabbits as the control and 12 rabbits for the histamine treated group following results were obtained: 1. Both of the concentration curves, arterial and venous, declined rapidly at_first and slowly later on and approached same equilibrium concentration with the passage of time after a single injection. The time at which attained the same concentration was $2.0{\pm}0.54\;min.$ in the control and $4.3{\pm}1.92\;min.$ in the histamine treated group with respect to antipyrine. On the other hand in the case of urea they were $2.4{\pm}0.59\;min.$ in the control and $4.4{\pm}1.31\;min.$ in the histamine group, respectively. In the histamine treated group enlarged spaces for distribution of test substances were postulated. 2. The concentration of antipyrine in the brain tissue water revealed no significant differences between the control and experimental groups, showing $212{\pm}40.2\;mg/l$ in the control and $206{\pm}64.1\;mg/l$ in the histamine treated group. On the other hand urea revealed higher value in the histamine treated group than in the control, showing an enhanced penetration of urea into the tissue after injection of histamine. Urea concentration in the brain water was $32.3{\pm}3.36\;mg%$ in the control and $39.2{\pm}4.25\;mg%$ in the histamine treated group. 3. The distribution ratio of antipyrine in the brain tissue was very close to unity in the histamine treated animals as well as in the control. 4. The average of the distribution ratio of urea in the control animals was 0.77 and it showed the presence of blood-brain barrier with regard to urea. However in the histamine treated animals the distribution ratios climbed up to 0.86 and they were closer to unity than in the control animals. Out of 12 cases 5 were greater than 0.9 and 8 exceeded 0.85. It appeared that histamine enhanced the penetration of urea through the barrier. 5. Histamine injection and or hemorrhage caused an elevation of the concentration of potassium in plasma. In the event that histamine and hemorrhage were applied together the elevation of potassium exceed the elevation seen at the histamine alone. There was no evidence that the leakage of potassium from the brain tissue was dominant in comparison with the general leakage from the whole body.

  • PDF

A Feasibility Study on GMC (Geo-Multicell-Composite) of the Leachate Collection System in Landfill (폐기물 매립시설의 배수층 및 보호층으로서의 Geo-Multicell-Composite(GMC)의 적합성에 관한 연구)

  • Jung, Sung-Hoon;Oh, Seungjin;Oh, Minah;Kim, Joonha;Lee, Jai-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.4
    • /
    • pp.67-76
    • /
    • 2013
  • Landfill require special care due to the dangers of nearby surface water and underground water pollution caused by leakage of leachate. The leachate does not leak due to the installation of the geomembrane but sharp wastes or landfill equipment can damage the geomembrane and therefore a means of protecting the geomembrane is required. In Korea, in accordance with the waste control act being modified in 1999, protecting the geosynthetics liner on top of the slope of landfill and installing a drainage layer to fluently drain leachate became mandatory, and technologies are being researched to both protect the geomembrane and quickly drain leachate simultaneously. Therefore, this research has its purpose in studying the drainage functions of leachate and protection functions of the geomembrane in order to examine the application possibilities of Geo-Multicell-Composite (GMC) as a Leachate Collection Removal and Protection System (LCRPs) at the slope on top of the geomembrane of landfill by observing methods of inserting filler with high-quality water permeability at the drainage net. GMC's horizontal permeability coefficient is $8.0{\times}10^{-4}m^2/s$ to legal standards satisfeid. Also crash gravel used as filler respected by vertical permeability is 5.0 cm/s, embroidering puncture strength 140.2 kgf. A result of storm drain using artificial rain in GMC model facility, maxinum flow rate of 1,120 L/hr even spray without surface runoff was about 92~97% penetration. Further study, instead of crash gravel used as a filler, such as using recycled aggregate utilization increases and the resulting construction cost is expected to savings.

Analysis on the Characteristics of Nonpoint sources during the Precipitation in Residential Area (강우 시 주거지역에서의 비점오염원 유출특성 분석)

  • Kwon, Heongak;Im, Toehyo;Na, Seungmin;Lee, Chunsik;Cheon, Seuk
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.391-401
    • /
    • 2015
  • In this study, divided into small category groups for the residential area it was carried out monitoring for the runoff during precipitation. Based on the results analyzed according to the nonpoint sources Housing leakage characteristics. Analysis of the rainfall runoff and concentration of each type of exclusive detached house with apartments, in the majority of precipitation types runoff concentrations were higher in early. In the case of a difference of two points per runoff rate rainfall it was largely investigation. The average runoff is estimated loadings of BOD $101.1kg/km^2$, SS $232.2kg/km^2$, T-N $18.2kg/km^2$, T-P $2.0kg/km^2$ detached house case, if the apartment was estimated at point BOD $108.82kg/km^2$, SS $329.18kg/km^2$, T-N $57.67kg/km^2$, T-P $4.21kg/km^2$. The average EMCs is BOD BOD 6.6 mg/L, SS 12.8 mg/L, T-N 1.518 mg/L, T-P 0.099 mg/L detached house case, if the apartment was estimated at point BOD 6.3 mg/L, COD 11.2mg/L, SS 14.5 mg/L, T-N 3.1 mg/L, T-P 0.2 mg/L. The initial 30 percentage calculated based on the initial results, the total flow of 30% if the outflow of detached house showed a net percentage difference to T-P 1.04 > T-N 0.97 > BOD 0.90 > SS 0.80. The apartment area showed the percentage difference in the water quality in the order of BOD 1.49 > T-P 1.40 > SS 1.30 > T-N 0.96 per item.