• 제목/요약/키워드: Leakage Flow Characteristic

검색결과 46건 처리시간 0.022초

자성유체의 온도에 따른 점성 변화를 이용한 미소 유체 소자 (The Microfluidic Device using Viscosity Deviation of Magnetic Fluids Due to Temperature Changes)

  • 최범규;오재근;안정재
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.473-478
    • /
    • 2004
  • This study focused on the charateristic of magnetic fluids, the viscosity deviation of magnetic fluids due to temperature changes, and fabrication of a 'purely' liquid type microvalve. The viscosity of magnetic fluids decreases sharply during increasing of temperature. The viscosity of magnetic fluids is rated 1,000 cP at the room temperature and 25 cP when the temperature reaches $100^{\circ}C$. Briefly, it is remarkable that the fluid flow can be controlled by the temperature and this characteristic can be adopted to the microfluidics as a microvalve. The fabrication of a liquid type microvalve is more easy than solid state microvalves and which can increase an efficiency of the controlability with respect to the thermo-pneumatic micropump which is studied broadly for many years. When the magnetic fluid used as a sealant for high level sealing, the pressure leakage is less than solid state microvalve. The experimental results show that the pressure drop in microchannel, filled with the magnetic fluid, is significant in the temperature range of $20^{\circ}C{\sim}50^{\circ}C$ and this result explains why the use of magnetic fluids is possible as a microvalve searcher uses this characteristics. Well known thermo-pnumatic.

통계적 가설검정을 이용한 중심형 버터플라이 밸브의 신뢰성 평가 (Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test)

  • 장무성;최종식;최병오;김도식
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1305-1311
    • /
    • 2015
  • 버터플라이 밸브는 일반적으로 유량을 조절하기 위해 사되는 유량 제어 장치의 일종이다. 본 연구에서는 중심형 버터플라이 밸브의 개선 전후 제품에 대한 신뢰성 시험 데이터의 통계적 분석을 통하여 버터플라이 밸브에 대한 와이블 분포의 형상모수, 특성수명 및 $B_{10}$ 수명을 추정한다. 또한 통계적 가설검정을 이하여 개선 전후 제품의 형상모수와 척도모수에 대한 차이를 검토한다. 가설검정 결과로부터 개선 전후 제품의 형상모수는 유사하며, 척도모수는 증가함을 알 수 있었다. 이러한 분석결과는 향후 신뢰성 인증시험이나 제품에 대한 보증수명 설정에 유한 정보로 활용될 수 있다.

반야월층(半夜月層)의 지하수운동(地下水運動)에 관(關)한 연구(硏究) (A Studyon the Movment of Ground Water of Banayweol Formation)

  • 김영기
    • 자원환경지질
    • /
    • 제9권4호
    • /
    • pp.225-240
    • /
    • 1976
  • This study deals with the flow of bed rock ground water of Banyaweol Formation, which is presently cleared up as a laminar flow. The result obtained may be summarized as the following. 1) The Banyaweol Formation consists mainly of thin-bedded, green to blackish green shale, mudstone, and marl. The marl and mudstone alternatively occur with shale. The marl and mudstone form a aquifer of Banyaweol Formation. In this study, a group of aquifer is in convenience named as a aquifer zone. The aquifer occurs in lenticular form. The aquifer seems to be a type of artesian aquifer because it is covered with aquicludes, but it actually forms a unconfined aquifer because its piezometric surface stays under the lower aquiclude. The lowering of piezometric level is formed because of leakage of the ground water to the lower aquifer undersaturated. 2) The coefficient of permeability of Banyaweol Formation's ground water body (K) is derived by using Dupuit's equation as the following ${\log}K=\frac{CK^2-dK+f}{aK-b}\;\(M=1.365(2H-s)s\\M={\log}1.956s{\sqrt{H}}r\)$ here, $$a=\sum_{1}M_iG_i$$ $$b={\frac{1}{2}log{\sum_{i}}Q_i{^2}$$ $$c=2{\sum_{i}}M_i{^2}$$ $$d=loge{\sum_{i}}M_{i}Q_{i}+2{{\sum_{i}}N_{i}Q_{i}$$ $$f=loge{\sum_{i}}Q_i{^2}N_i$$ If the measured values substituted for the above equation, the coefficient of permeability of the aquifer is 4.1m/day. The coefficient of storge of the aquifer is $2.8{\times}10^{-4}$ if the measured values substituted for Theis's equation. Using the above constants, the filtration velocity of the aquifer is $2.1{\times}1O^{-1}m/day$and the daily flow quantity of the ground water is $847.38m^{3}/day$. 3) In order to understand the time necessary for a circulation of ground water body, the contents of tritum contained in the ground water are measured as 2.3 T.U. at the Korea Atomic Energy Research Institute. Before 1952, the average concentration of tritium per year in groundwater was reported as 10T. u., taking it as the standard, the groundwater of the present study 26.25 years old. Therofore, the groundwater of the Banyaweol Formation is judged as an relatively old groundwater. It is characteristic that the ground water of Banyawol Formation is laminar flow as well as unconfined aquifer and ground water flow of relatively long time. 4) The nature, means of flow, and circulation of Banyaweol Formation's ground water body make it possible set up this ground water body as a ground water system.

  • PDF

곡물냉각기를 이용한 철제 원형빈에서 벼 냉각 (Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler)

  • 김의웅;김동철
    • 한국식품저장유통학회지
    • /
    • 제11권2호
    • /
    • pp.263-268
    • /
    • 2004
  • 곡물냉각기를 이용하여 벼의 냉각특성을 구명하기 위하여 RPC의 원형빈에서 2회의 냉각실험을 실시하였다. 1차 냉각 실험은 하절기에 200 톤 규모의 원형빈에서, 2차 냉각실험은 수확기에 300 톤 규모의 원형빈에 저장된 벼를 대상으로 실시하였다. 그 결과를 요약하면 다음과 같다. 1차 냉각실험에서 초기곡온 23.6$^{\circ}C$, 함수율 19.3%인 벼180.3 톤을 14$^{\circ}C$까지 냉각시키는데 52.5시간이 소요되었으며, 냉각을 통해 함수율은 약 0.6% 감소하였다. 또한, 2차 냉각실험에서 초기곡온 16.1$^{\circ}C$, 함수율 19.2%인 벼 272.2 톤을 5.5$^{\circ}C$까지 냉각시키는데 78.0시간이 소요되었다. 1, 2차 냉각실험에서 냉각공기온도를 각각 8.0, 5.5$^{\circ}C$로 설정하였을 때, 곡물냉각기출구의 냉각공기온도는 각각 8.0$\pm$0.48$^{\circ}C$, 5.7$\pm$0.84$^{\circ}C$로서 정밀하게 제어되고 있음을 알 수 있었으며, 2차 냉각실험에서의 온도편차가 1차 냉각실험에서보다 높게 나타난 것은 냉각부하가 적었고, 외기조건이 급격하기 변화하여 압축기 무부하전자변, 재열기 및 증발기에 공급되는 고온고압 냉매가스량, 응축기 송풍기가 제어되었기 때문으로 판단되었다. 1차 냉각실험에서 곡물냉각기에서 냉각된 공기량은 평균77.5㎥/min인데 비해 곡물층을 통과한 냉각공기량은 42.5㎥/min에 불과해 약 45%의 냉각공기가 누설되어 이에 대한 방지책이 필요하였다. 냉각부하가 큰 하절기에 실시한 1차 냉각실험에서는 댐퍼만이 제어되었으며, 소요전력은 평균 22.1㎾를 나타낸 반면, 냉각부하가 적은 수확기에 실시한 2차 냉각실험에서는 압축기의 무부하전자변, 응축기 송풍기 등이 제어되었으며, 소요전력은 평균 17.4㎾로 나타나 하절기에 비하여 약 27%정도의 에너지가 절감된 것으로 나타났다.

누수대수층 지하수 양수에 관한 Hunt 해석해의 적용성 평가 (Evaluating Applicability of Hunt's Analytical Solution for Groundwater Pumping from a Leaky Aquifer)

  • 이정우;정일문
    • 대한토목학회논문집
    • /
    • 제40권6호
    • /
    • pp.555-561
    • /
    • 2020
  • 본 연구에서는 상, 하부 2개의 대수층이 연결된 누수대수층에 대해 상부 1층 지하수 양수로 인한 하천수 감소량을 산정하기 위해 개발된 Hunt 해석해의 적용성을 평가하였다. 두 대수층의 투수량계수 및 저류계수, 층간 누수계수, 하천-관정 이격거리, 하상의 수리전도도, 하폭 등 다양한 수리특성치 크기 조합에 따라 양수 후 5년 평균 하천수 감소량을 해석해로 산정하고, 범용적으로 사용되고 있는 MODFLOW 지하수유동모형으로 정교하게 모의된 수치해와의 비교를 통해 하폭을 점으로 간주하여 유도한 해석해 적용 결과가 정확한지를 평가하였다. 그 결과 하천-관정 이격거리가 하폭 이상되거나, 하천고갈인자(Stream Depletion Factor)가 약 3,000일 이어야 해석해로 산정한 하천수 감소비의 오차를 0.05 아래로 줄일 수 있는 것으로 분석되었다. 또한 하상수리전도성이 1 m/d 보다 작거나, 하부대수층의 수리확산계수가 100 ㎡/d 보다 작거나, 상부와 하부대수층의 수리확산계수비가 5 이상, 층간 누수계수가 0.0004 m/d 보다 작을 때 해석해가 수치해에 비해 전반적으로 과다하게 산정되는 것으로 분석되었다.

유속에 따른 ERW 탄소강관의 홈부식 특성에 관한 연구 (A study on the characteristic of the Groove corrosion of ERW carbon steel according to water speed)

  • 김재성;이영기;김용;이보영
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.82-82
    • /
    • 2009
  • 강관은 물, 유류, 천연 가스 등을 운송하는 배관용 및 건물의 골조, 유압 및 공압 실린더, 가이드 레일 등 의 기계적 부품으로도 널리 사용되기도 한다. 이렇게 사용되는 강관의 70% 이상은 고주파 전기저항용접(High Frequency Electrical Resistance Welding,이하 ERW)으로 제조되고 있다. 아파트 등 실제 현장에서 ERW 강관에 흐르는 유체는 비드가 제거된 내면 부위에서 와류 (vortex)를 일으켜 기계적 침식(erosion)을 수반할 가능성이 있으며, 수격현상으로 인해 부식 부위에서 반복피로 하중을 받아 부식의 전파속도가 증가되어 최종적 으로 파손되는 경우도 예상할 수 있다. 이에 본 연구에서는 입열량을 달리하여 제조된 ERW 강관을 대상으로 강관 내부에서의 유속에 따라 홈부식 감수성에 미치는 영향을 확인하고자 하였다. 이를 위해 실제 사용 환경을 모사할 수 있는 장치를 제작하고 경계 조건을 선정하여 실험을 실시하였다. ERW 강관의 내부에서 유속이 빨라질 경우 부식속도는 증가를 하였고, 입열을 많이 받은 강관의 경우 부식속도가 감소하는 경향을 가졌다. 이러한 결과를 바탕으로 하여 ERW 강관에서 발생하고 있는 결함발생에 의한 피해를 극소화시킴으로서 안전하고 효율적인 관리에 기여하고자 한다.

  • PDF