• Title/Summary/Keyword: Leakage Defects

Search Result 178, Processing Time 0.023 seconds

A study on Monitoring the Inner Structure of Dam Body Using High Resolution Seismic Reflection Method (고분해능 탄성파 반사법을 이용한 댐체 내부구조 모니터링 연구)

  • Kim, Jung-Yul;Kim, Hyoung-Soo;Oh, Seok-Hoon;Kim, Yoo-Sung
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • Defects of dam body which can be induced in seepage or leakage procedure can directly affect dam safety. Therefore, a proper inspection method should be carried out in the first place to find out their positions and sizes. After that, some reinforcement works such as grouting and the corresponding assessment could be taken in a proper way. The dam(center core type earth dam) issued in this study has been in need for intensive diagnosis and reinforcement work, because a lot of slumps similar to cracks, seepage and some boggy area have been observed on the downstream slope. High resolution seismic reflection method was performed on the crest profile twice before and after grouting work(Aug. 2001 and Nov. 2004) aimed at the dam inspection and the assessment of grouting efficiency as well. To enhance the data resolution, P-beam energy radiation technique which can reduce the surface waves and hence to reinforce the reflection events was used. Strong reflection events were recognized in the stack section before grouting work, It seems that the events would be caused by e.g. horizontal cracks with a considerable aperture. Meanwhile such strong reflection events were not observed in the section after grouting. That is, the grouting work was dear able to reinforce the defects of dam body. Hence, the section showed an well arranged picture of dam inner structure. In this sense, seismic reflection method will be a desirable technique for dam inspection and for monitoring dam inner structure as well.

  • PDF

Maxillofacial rehabilitation of hemi-maxillectomy patient using a closed hollow bulb obturator fabricated by one-step polymerization technique: a clinical report (상악골 부분절제술 시행 환자에서 one-step 중합 기술로 만든 hollow bulb 폐색장치를 이용한 악안면 수복 증례)

  • Sim, Jae-Hyuk;Kim, Min-Kyoo;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.35-40
    • /
    • 2016
  • The maxillary defects lead to anatomical and functional deformity of the maxillofacial region. As far as functions are concerned, such defects can produce difficulty in speech, mastication, and deglutition. Obturator prostheses play a very important role in functional recovery for post-maxillectomy patients. To achieve rigidity of the obturator, appropriate retention should be given, and the weight of the prosthesis be reduced. There are two types of hollow bulb obturator: open and closed. A closed type has many advantages. Nevertheless, some problems, including complexity of fabrication and water leakage into the bulb, have the closed hollow obturator not be widely used. The one-step polymerization technique described in this case overcomes the shortcomings by easily constructing a small hollow bulb with two thermoplastic resin sheets.

Characteristics of defect on segmental lining of TBM tunnel in operational subway (운용중인 국내 지하철 TBM터널의 세그먼트라이닝 결함특성 분석)

  • Choo, Jinho;Lee, DongHun;Noh, EunChul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.109-128
    • /
    • 2022
  • The precise inspection for safety and diagnosis (PISD) of tunnel has been conducted by the special act on safety control of public structures. However, the present assessment for the segmental lining of TBM tunnel has limitation such as: NDTs for integrity, segmental configuration for field inspection, and consideration for jacking system. Even if the number of TBM tunnel is less than 1% of enrolled facility in FMS, more attention to maintenance should be necessary due to its usage such as multi-use facility and national important facility. Compared to NATM tunnel, excavated by drilling and blasting and then installed lining by cast-in-place within 6~12 m, TBM tunnel is cut out ground by disk and cutter-bit and then assembled 7 pieces of precast segment, 1.2~1.4 m wide. Different features of design, construction, and maintenance should be considered to be more exact evaluation of TBM tunnel. The characteristics of defect is categorized and analyzed with 11 operational TBM tunnels in domestic subway. To be more comprehend various particular defects, foreign studies have been also adapted. Crack and leakage are categorized in 7 patterns. Breakage/spalling and corrosion are also grouped into 3 patterns. Patterned defects or damages are fed back in design, construction, and are useful guidelines for maintenance stage in future.

Effects of transition layer in SiO2/SiC by the plasma-assisted oxidation

  • Kim, Dae-Gyeong;Gang, Yu-Seon;Gang, Hang-Gyu;Baek, Min;O, Seung-Hun;Jo, Sang-Wan;Jo, Man-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.193.2-193.2
    • /
    • 2016
  • We evaluate the change in defects in the oxidized SiO2 grown on 4H-SiC (0001) by plasma assisted oxidation, by comparing with that of conventional thermal oxide. In order to investigate the changes in the electronic structure and electrical characteristics of the interfacial reaction between the thin SiO2 and SiC, x-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XAS), DFT calculation and electrical measurements were carried out. We observed that the direct plasma oxide grown at the room temperature and rapid processing time (300 s) has enhanced electrical characteristics (frequency dispersion, hysteresis and interface trap density) than conventional thermal oxide and suppressed interfacial defect state. The decrease in defect state in conduction band edge and stress-induced leakage current (SILC) clearly indicate that plasma oxidation process improves SiO2 quality due to the reduced transition layer and energetically most stable interfacial state between SiO2/SiC controlled by the interstitial C.

  • PDF

(A Study on the Annealing Methods for the Formation of Shallow Junctions) (박막 접합 형성을 위한 열처리 방법에 관한 연구)

  • 한명석;김재영;이충근;홍신남
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Low energy boron ions were implanted into the preamorphized and crystalline silicon substrates to form 0.2${\mu}m$ $p^+-n$ junctions. The rapid thermal annealing(RTA) was used to annihilate the crystal defects due to implantation and to activate the implanted boron ions, and the furnace annealing was employed to reflow the BPSG(bolo-phosphosilicate glass). The implantation conditions for Gepreamorphization were the energy of 45keV and the dose of 3$\times$1014cm-2. BF2 ions employed as a p-type dopant were implanted with the energy of 20keV and the dose of 2$\times$1015cm-2. The thermal conditions of RTA and furnace annealing were $1000^{\circ}C$/10sec and $850^{\circ}C$/40min, respectively. The junction depths were measured by SIMS and ASR techniques, and the 4-point probe was used to measure the sheet resistances. The electrical characteristics were analyzed via the leakage currents of the fabricated diodes. The single thermal processing with RTA produced shallow junctions of good qualities, and the thermal treatment sequence of furnace anneal and RTA yielded better junction characteristics than that of RTA and furnace anneal.

Complications after Senning Operation for TGA with and Wothout VSD (대혈관전위증에서 Senning수술후 합병증에 관한 임상적 고찰)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.595-603
    • /
    • 1993
  • We analysed 60 consecutive patients who got Senning operation for transposition of the great arteries [TGA] with or without ventricular septal defects [VSD]. There were 41 simple TGA [group I] and 19 TGA with VSD [Group II], the operative mortality was 20 % [in group I 4.9 %, group II 52.6 %]. Among the survivors [n=48], the mean follow-up period was 7 years [range, 1 year to 13.5 years] and the actuarial survival rate at 13 years were 95 % in group I and 42 % in group II. Preoperative high left ventricular pressure and high pulmonary arterial pressure affected the surviving [p<0.01]. There occurred various type of arrhythmia like junctional rhythm, first degree atrioventricular [AV] block, sick sinus syndrome and complete AV block, and we inserted 2 permanent pacemakers for these patients. The incidence of arrhythmia were 28.2 % [11/39] in group I and 55.6 % [5/9] in group II, and the actuarial freedom from arrhythmia at 13 years after operation was 66 % [71 % in group I, 44 % in group II]. Increased aortic cross clamping time had affected the development of arrhythmia [p<0.05] which meant the complexity of the operation. The total incidence of left ventricular outflow tract obstruction [LVOTO] was 31.3 % [15/48], but only 3 patients [6.25 %] showed the significant gradient requiring reoperation. The pulmonary venous pathway obstruction [PVO] were found in 3 patients, all in group I, and among them only one required the reoperation. The estimated freedom from PVO was 89 % at 13 years [87 % in group I, 100 % in group II], but we couldn`t find any significant systemic venous obstruction in our series. There occurred 27.1 % [13/48] mild degree tricuspid valve regurgitation without necessary surgical correction. We experienced 14.6 % [7/48] reoperation rate: 3 residual VSD, 3 LVOTO, 1 PVO, 3 atrial baffle leakage. For this high incidence of complication rate after Senning operation and high mortality in TGA with VSD, We do not use this kind of surgical modality any more and do the Jatene operation for all the TGA patients since several years ago.

  • PDF

Application of a New NDI Method using Magneto-Optical Film for Inspection of Micro-Cracks (미소균열 탐상을 위한 자기광학소자를 이용한 비파괴탐상법의 제안과 적용)

  • Lee, Hyoung-No;Park, Han-Ju;Shoji, Tetsuo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.197-203
    • /
    • 2001
  • Micro-defects induced by design and production failure or working environments are known as the cause of SCC(Stress Corrosion Cracking) in aged structures. Therefore, the evaluation of structural integrity based on micro-cracks is required not only a manufacturing step but also in-service term. So we introduce a new nondestructive inspection method using the magneto-optical film to detect micro-cracks. The method has some advantage such as high testing speed, real time data acquistion and the possibility of remote sensing by using of a magneto-optical film that takes advantage of the change of magnetic domains and domain walls. This paper introduces the concept of the new nondestructive inspection method using the magneto-optical film, also proves the possibility of this method as a remote testing system under oscillating load considering application on real fields by applying the method to four types of specimens.

  • PDF

Blood-Brain Barrier Experiments with Clinical Magnetic Resonance Imaging and an Immunohistochemical Study

  • Park, Jun-Woo;Kim, Hak-Jin;Song, Geun-Sung;Han, Hyung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.203-209
    • /
    • 2010
  • Objective : The purpose of study was to evaluate the feasibility of brain magnetic resonance (MR) images of the rat obtained using a 1.5T MR machine in several blood-brain barrier (BBB) experiments. Methods : Male Sprague-Dawley rats were used. MR images were obtained using a clinical 1.5T MR machine. A microcatheter was introduced via the femoral artery to the carotid artery. Normal saline (group 1, n = 4), clotted autologous blood (group 2, n = 4), triolein emulsion (group 3, n = 4), and oleic acid emulsion (group 4, n = 4) were infused into the carotid artery through a microcatheter. Conventional and diffusion-weighted images, the apparent coefficient map, perfusion-weighted images, and contrast-enhanced MR images were obtained. Brain tissue was obtained and triphenyltetrazolium chloride (TTC) staining was performed in group 2. Fluorescein isothiocyanate (FITC)-labeled dextran images and endothelial barrier antigen (EBA) studies were performed in group 4. Results : The MR images in group 1 were of good quality. The MR images in group 2 revealed typical findings of acute cerebral infarction. Perfusion defects were noted on the perfusion-weighted images. The MR images in group 3 showed vasogenic edema and contrast enhancement, representing vascular damage. The rats in group 4 had vasogenic edema on the MR images and leakage of dextran on the FITC-labeled dextran image, representing increased vascular permeability. The immune reaction was decreased on the EBA study. Conclusion : Clinical 1.5T MR images using a rat depicted many informative results in the present study. These results can be used in further researches of the BBB using combined clinical MR machines and immunohistochemical examinations.

Diagnosis Method and Characteristic Analysis of Shorted Turns on Generator Rotor using Flux Sensorless (자속센서리스 회전자 층간단락 진단기법 및 특성해석)

  • Kim Sun-Ja;Jeon Ywun-Seok;Lee Seung-Hak;Jeong Byung-Hwan;Lee Myung-Un;Choe Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.257-263
    • /
    • 2005
  • Short-circuit rotor windings on a generator causes unstable oscillation of unbalance of flux, asymmetrical heat. In order to prevent serious accidents of short-circuit rotor windings, it is important to study the shorted-turn diagnosis method for rotor windings of the generator. To improve the defects of the diagnosis with sensors, the new sensorless method for rotor shorted-turn diagnosis is proposed, which is to measure the electrical values of the voltage and current at the generator and then to detect if the shorted-turned phenomena would occurred. For the feasibility of the suggested method the theoretical results are shown in the aspects of the air-gap flux density, the flux leakage, the generated output voltage and the shorted field current through the digital simulation. Also the possibility of decision for the suggested sensorless method could be shown in this paper.

Comparing the Passivation Quality of Ozone and H2O Oxidant of Atomic Layer Deposited Al2O3 by Post-annealing in N2 and Forming Gas Ambients for Passivated Emitter and Rear Cell (PERC)

  • Cho, Young Joon;Chang, Hyo Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.462-462
    • /
    • 2014
  • The effect of rear passivation for passivated emitter and rear cell (PERC) using ozone and H2O oxidant of atomic layer deposited (ALD) Al2O3 was studied by post-annealing in N2 and forming gas ambients. Rear surface of PERC solar cell was passivated by Al2O3 grown by ALD with ozone and H2O oxidant. Al2O3 grown by ALD with ozone oxidant has been known to have many advantages, such as lower interface defects, low leakage current density. Its passivation quality is better than Al2O3 with H2O. Al2O3 layer with 10 nm and 20 nm thickness was grown at $150^{\circ}C$ with ozone oxidant and at $250^{\circ}C$ with H2O oxidant. And then each samples were post-annealled at $450^{\circ}C$ in N2 ambients and at $850^{\circ}C$ in forming gas ambients. The passivation quality was investigated by measuring the minority carrier lifetime respectively. We examined atomic layer deposited Al2O3 such as growth rate, film density, thickness, negative fixed charge density at AlOx/Si interface, and reflectance. The influences of process temperature and heat treatment were investigated using Sinton (WCT-120) by Quasi-Steady State Photoconductance (QSSPC) mode. Ozone-based ALD Al2O3 film shows the best carrier lifetime at lower deposition temperature than H2O-based ALD.

  • PDF