• Title/Summary/Keyword: Leak rate

Search Result 263, Processing Time 0.16 seconds

Risk Assessment of Integrated Leak Rate Test(ILRT) Extension for Korea Standard Nuclear Power Plant (한국표준형원전의 격납건물종합누설률 시험 주기연장에 대한 리스크 평가)

  • Chi, Moon-Goo;Hwang, Seok-Won;Oh, Ji-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.99-104
    • /
    • 2011
  • An ILRT Interval for a nuclear power plant in Korea was extended from once in five years to once in ten years. Therefore, it is necessary to evaluate risk impact for ILRT interval extensions. In this paper, input data were generated for the reference plants, KSNP, using raw data such as meteorological data, population distribution data and source term data. And, using MACCS II code the risk impact assessment was performed based on the two methodologies of NUREG-1493 and NEI Interim Report. The risk impact derived from an ILRT interval extension was identified not to be significant. It is considered to apply this study and results to making an accident management plan and safety goal, and to the field of public acceptance.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

Photodynamic Diagnosis and Therapy for Peritoneal Carcinomatosis from Gastrointestinal Cancers: Status, Opportunities, and Challenges

  • Kim, Hyoung-Il;Wilson, Brian C.
    • Journal of Gastric Cancer
    • /
    • v.20 no.4
    • /
    • pp.355-375
    • /
    • 2020
  • Selective accumulation of a photosensitizer and the subsequent response in only the light-irradiated target are advantages of photodynamic diagnosis and therapy. The limited depth of the therapeutic effect is a positive characteristic when treating surface malignancies, such as peritoneal carcinomatosis. For photodynamic diagnosis (PDD), adjunctive use of aminolevulinic acid- protoporphyrin IX-guided fluorescence imaging detects cancer nodules, which would have been missed during assessment using white light visualization only. Furthermore, since few side effects have been reported, this has the potential to become a vital component of diagnostic laparoscopy. A variety of photosensitizers have been examined for photodynamic therapy (PDT), and treatment protocols are heterogeneous in terms of photosensitizer type and dose, photosensitizer-light time interval, and light source wavelength, dose, and dose rate. Although several studies have suggested that PDT has favorable effects in peritoneal carcinomatosis, clinical trials in more homogenous patient groups are required to identify the true benefits. In addition, major complications, such as bowel perforation and capillary leak syndrome, need to be reduced. In the long term, PDD and PDT are likely to be successful therapeutic options for patients with peritoneal carcinomatosis, with several options to optimize the photosensitizer and light delivery parameters to improve safety and efficacy.

Chiari Type III : Experience of Outcome for 15 Cases

  • Gabr, Mohamed;Elmataeshy, Mahmoud;Abdullah, Ahmed A.
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.841-845
    • /
    • 2022
  • Objective : Chiari III malformations are extremely rare hindbrain malformations that are associated with a high early mortality rate, or severe neurologic deficits in the survivors. The treatment is early operative closure and cerebrospinal fluid diversion (CSF) shunting. Methods : We operated on 15 patients by repair and excision between July 2014 till June 2020 and retrospective data collection was done. Only one patient doesn't need ventriculoperitoneal (VP) shunt and the other 14 patients need a VP shunt. We described stepwise dissection and untethering of the cerebellum from the bony edge to regrowth and herniation of cerebellum again into this potential space and simple dural closure or repair with graft was done. Results : We started with VP in eight patients (53%) and the other seven patients (46.7%) started with excision and then six patients need VP shunt later on because four patients developed CSF leak and two patients developed increased high intracranial tension. Only four patients (26.7%) needed a blood transfusion. Conclusion : There are variations in the outcome and not all cases of Chiari malformation III will die and severe developmental delay is not a must. Proper management and repair carry a good prognosis.

Closed-Loop Cooling System for High Field Mangets (고자기장용 자석을 위한 밀폐순환형 냉각장치)

  • Choi, Y.S.;Kim, D.L.;Lee, B.S.;Yang, H.S.;Painter, T.A.;Miller, J.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • A closed-loop cryogenic cooling system for high field magnets is presented. This design is motivated by our recent development of cooling system for 21 tesla Fourier Transform ion Cyclotron Resonance (FT-ICR) superconducting magnets without any replenishment of cryogen. The low temperature superconducting magnets are immersed in a subcooled 1.8 K bath, which is connected hydraulically to the 4.2 K reservoir through a narrow channel. Saturated liquid helium is cooled by Joule-Thomson heat exchanger and flows through the JT valve, isenthalpically dropping its pressure to approximately 1 6 kPa, corresponding saturation temperature of 1.8 K. Helium gas exhausted from pump is now recondensed by two-stage cryocooler located after vapor purify system. The amount of cryogenic Heat loads and required mass flow rate through closed-loop are estimated by a relevant heat transfer analysis, from which dimensions of JT heat exchanger and He II heat exchanger are determined. The detailed design of cryocooler heat exchanger for helium recondensing is performed. The effect of cryogenic loads, especially superfluid heat leak through the gap of weight load relief valve, on the dimensions of cryogenic system is also investigated.

Analysis of Defect Repair Cost by Work Type based on Defect Inspection of Apartments (공동주택의 하자진단에 기초한 공종별 하자보수비용의 분석)

  • Lee, Jin-Eung;Kim, Byung-Yun;Jeong, Byung-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.5
    • /
    • pp.491-500
    • /
    • 2015
  • This study investigated defect status by work type, based on the report data of defect inspection results, acquired by consumers' request to safety inspection agencies, before the expiration of legal defect repair warranty period. In fact, the data was not acquired by centering on suppliers, namely, construction companies in relation with the defects becoming causes to increase construction cost of apartments. This study aims to provide objective and basic data for quality improvement at construction stage and for solution to defect disputes. The study results are presented below: (1) The number of defect cases occurring from architectural work among total work types were 1,986, defect occurrence rate was 62.5%, and defect repair cost was KRW $25,851/m^2$, which stood at 78.2% of the total work types. This means the defect occurrence rate and defect repair cost in architectural work are bigger than those of other work types. (2) Major defects in architectural work were revealed in the following order: cracks from frame work, inferior interior finishing work, inferior finishing work of plaster/masonry works, water leak/damage from waterproof work and withering/omission from landscape work. The total repair cost of the major selected defects was KRW $12,220/m^2$, and was analyzed to take up 37% of the total defect repair cost.

Repeated Transsphenoidal Surgery for Pituitary Tumors (경접형골동접근법에 의한 뇌하수체종양의 재수술)

  • Koh, Young-Cho;Yoo, Heon;Kim, Chang-Hyun;Whang, Do-Yun;Jang, Jin-Soon;Park, Hyo-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.929-934
    • /
    • 2000
  • Objective : The results of secondary transsphenoidal surgery(TSS) for either residual or recurring pituitary adenomas have been reported to be unfavorable. To evaluate the effectiveness of secondary TSS, we analyzed the surgical results of residual or recurred pituitary adenomas in patients who underwent secondary TSS from 1992 to 1998. Material and Methods : Among the 95 patients who underwent TSS during this period, 14(15%) received repeated TSS. Two of the 14 patients underwent three TSS. Among the 11 patients with pituitary adenomas, three had nonfunctioning tumors ; six prolachnomas ; two GH-secreting adenomas. The remaining three patieats had craniopharyngioma, pituitary abscess and hemangioendothelioma respectively. The interval between the two surgical procedures ranged from one week to 33 months(mean ; 12 months). Causes of the secondary TSS were tumor recurrence in 11 patients, intentional staged operation in three, persistent disease despite medical therapy and CSF leak after initial operation in one respectively. Treatments prior to secondary TSS were medical treatment only in eight patients. Results : During the repeated operationtss some adhesion was noted in septal mucous membrane. The sphenoid cavity was filled with fibrous tissue which correlated with the methods of reconstruction of the sellar floor at the previous operation. There was no statistically significant difference in success rate of surgery between the initial and the second TSS(86% vs 81%). The complication rate was similar between the two procedures. There was no statistically significant factors affecting the results of second TSS. Conclusion : Transsphenoidal reoperation was regarded as a suitable approach for treating recurrent pituitary adenomas in spite of some degree of operative difficulties. In patients with transsphenoidally resectable tumor residuals or recurrences confirmed by magnetic resonance imaging, remissions can be obtained with high probability, especially in secondary surgery after an staged decompression.

  • PDF

A Study on Hydrogeologic, Hydrodispersive Characterization and Groundwater Contamination Assessment of an H-site (H 연구지역의 수리지질-수리분산특성과 지하수 오염가능성 평가연구)

  • Hahn, Jeongsang
    • Economic and Environmental Geology
    • /
    • v.27 no.3
    • /
    • pp.295-311
    • /
    • 1994
  • A comprehensive in-situ tests are performed to define the hydrogeologic and hydrodispersive characteristics such as hydraulic conductivities, longitudinal dispersivity, and average linear velocities as well as conducting flow-net analysis at the study area. The results show that the study area is very heterogeneous so that hydraulic conductivities range from $6.45{\times}10^{-7}$ to $1.15{\times}10^{-5}m/s$ with average linear velocities of 0.34~0.62m/day. Whole groundwater in upper-most aquifer is discharging into the sea with specific discharge rate of $7.2{\times}10^{-3}$ to $1.3{\times}10^{-2}m/day$. The longitudinal dispersivity of the aquifer is estimated about 4.8m through In-situ injection phase test. The area is highly vulnerable to potential contaminant sources due to it's high value of DRASTIC index ranging from 139 to 155 and also under water table condition with very shallow groundwater level. To delineate contaminant plumes of toxic NaOH and carcinogenic benzene when these substances are assumed to be leaked through existing TSDF at the study area by unexpected accidents or spill, Aquifer Simulation Model (ASM) including Flow and Transport Model is used. Te simulated results reveal that the size of NaOH plume after 5 years continuous leak is about $250{\times}100m$ and benzene after 10 years, $490{\times}100m$. When the groundwater is abstracted about 50 days, which is maximum continuously sustained no-precipitation period during 30 years, with pumping rate of $100m^3/day$, THWELL program shows that the groundwater is adversly affected by sea water intrusion.

  • PDF

Comparison of Aerodynamic Variables according to the Execution Methods of KayPENTAX Phonatory Aerodynamic System Model 6600 (KayPENTAX Phonatory Aerodynamic System Model 6600의 수행방법에 따른 공기역학 변수 비교)

  • Ko, Hyeju;Choi, Hong-Shik;Lim, Sung-Eun;Choi, Yaelin
    • Phonetics and Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.93-99
    • /
    • 2015
  • In case of PAS test, the air is sometimes leaked although the mask is tightly attached to the face, which is not reliable on the measured values. Therefore, this study aimed to assist the clinical practice suggesting the test method of PAS without air leakage. In the healthy subjects with 12 males and 12 females over 19 years old, three types of tests were performed on the voicing efficiency among the protocol of PAS Model 6600. They are; first, to attach the mask tightly to the face holding the handle of PAS with the subject's two hands (Method 1); second, to attach the mask tightly to the face holding the handle of PAS with the subject's one hand and pushing the body of PAS strongly with the other hand (Method 2); and third, to attach the mask tightly to the face pushing the upper part of the mask by the tester when the subject attached the mask to his or her face holding the handle of PAS with two hands (Method 3). Upon the study analyses, the mean negative pressure, the mean phonogram, subglottic air pressure, and voicing efficiency were shown to be statistically significantly different during PAS test in males depending on the methods. (p<.05) In case of females, only the target airflow rate showed significant difference depending on the methods during PAS test. (p<.001) In conclusion, Method 2 enhanced the noise level and strength while Method 1 was likely to leak the air more compared to the other two methods in males. In case of females, Method 1 showed significant leakage of the air flow. Not to allow the air flow leakage without affecting the outcome of PAS test, it will be the most useful for the tester to push the mask to the subject's face tightly (Method 3).

Measuring method of personal information leaking risk factor to prevent leak of personal information in SNS (SNS에서 개인정보유출방지를 위한 개인정보 유출위험도 측정 방법)

  • Cheon, Myung-Ho;Choi, Jong-Seok;Shin, Yong-Tae
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.6
    • /
    • pp.1199-1206
    • /
    • 2013
  • SNS is relationship based service and its users are increasing rapidly because it can be used in variety forms as penetration rate of Smartphone increased. Accordingly personal information can be exposed easily and spread rapidly in SNS so self-control on information management, right to control open and distribution of own personal information is necessary. This research suggest way of measuring personal information leaking risk factor through personal information leaking possible territory's, based on property value and relationship of personal information in SNS, personal information exposure frequency and access rate. Suggested method expects to used in strengthening self-control on information management right by arousing attention of personal information exposure to SNS users.