• Title/Summary/Keyword: Leak current

Search Result 103, Processing Time 0.025 seconds

Leakage Flux Distribution in the Simulated Environment

  • Kim, Chung-Hyeok;Kim, Tag-Yong;Oh, Yong-Cheul
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.401-405
    • /
    • 2012
  • Current research about voltage leakage involves investigation of the effects of leaked voltage and current on humans through simulated environments and dummies. Electrocution results from leaked current when electricity flows through the body as a result of potential difference. Research that analyzes actual electrocution is insufficient because of the danger from leaked voltage present in the leakage area. This thesis analyzes magnetic flux density from current around a leak to investigate the distribution of current. The authors used a simulated environment to investigate electrocution accidents that frequently occur during floods through leakage along metal surfaces, and evaluated the distribution of leaked magnetic flux.

Analysis of DC Traction Stray Current Interference on Buried Pipelines (지하철 누설전류가 도시가스 배관에 미치는 영향 해석)

  • Lee H.G.;Ha T.H.;Ha Y.C.;Bae J.H.;Kim D.K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1376-1378
    • /
    • 2004
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the cathodic protection systems of buried pipelines and DC traction stray current influence on it using the simulation software CatPro. We can discuss the problems and mitigation of DC traction interference for protected pipeline.

  • PDF

A Study on the Non-Contact Detection Technique of Defects Using AC Current - The Influence of Frequency and lift-off - (교류전류를 이용한 비접촉결함탐상법에 관한 연구 - 주파수 lift-off의 영향 -)

  • Kim, Hoon;Na, Eu-Gyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.53-58
    • /
    • 2002
  • New nondestructive inspection (NDI) technique to detect the defect in metal was developed in which an electromagnetic field is induced in a metal by AC current flowing in the magnetic coil and the leak magnetic-flux disturbed by defects is measured using a tape-recorder head with air gap. This technique can be applied in evaluating the location and sizing of surface defects in components of the ferromagnetic body by means of the non-contacting measurement. In this paper, we have applied this technique to the evaluation of two-dimensional surface cracks in ferromagnetic metal, and also investigated the influence of the various frequencies and lift-off. Defects were detected with maximum values in the distribution of voltage and it was found that the maximum values tend to increase with the defect depth. Although the maximum values for defects are affected by the frequency and lift-off, the depth of small defects can be estimated from the linear relationship between the depth and voltage rate$(V_0/V_{ave})$.

Numerical analysis on the critical current evaluation and the correction of no-insulation HTS coil

  • Bonghyun Cho;Jiho Lee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.1
    • /
    • pp.16-20
    • /
    • 2023
  • The International Electrotechnical Commission (IEC) 61788-26:2020 provides guidelines for measuring the critical current of Rare-earth barium copper oxide (REBCO) tapes using two methods: linear ramp and step-hold methods. The critical current measurement criterion, 1 or 0.1 μV/cm of electric field from IEC 61788-26 has been normally applied to REBCO coils or magnets. No-insulation (NI) winding technique has many advantages in aspects of electrical and thermal stability and mechanical integrity. However, the leak current from the NI REBCO coil can cause distortion in critical current measurement due to the characteristic resistance which causes the radial current flow paths. In this paper, we simulated the NI REBCO coil by applying both linear ramp and step-hold methods based on a simplified equivalent circuit model. Using the circuit analysis, we analyzed and evaluated both methods. By using the equivalent circuit model, we can evaluate the critical current of the NI REBCO coil, resulting in an estimation error within 0.1%. We also evaluate the accuracy of critical current measurement using both the linear ramp and step-hold methods. The accuracy of the linear ramp method is influenced by the inductive voltage, whereas the accuracy of the step-hold method depends on the duration of the hold-time. An adequate hold time, typically 5 to 10 times the time constant (τ), makes the step-hold method more accurate than the linear ramp method.

Influence on Lead Wire Method of Distributed ICCP Systems for Mitigation of DC Traction Interference (전철 간섭 대책용 분포형 외부전원시스템의 배관인출 방법에 따른 영향)

  • Lee, H.G.;Ha, Y.C.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.282-284
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on lead wire method of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF

Influence on Parallel Pipelines of Distributed ICCP Systems for Mitigation of DC Traction Interference (전철 간섭 대책용 분포형 외부전원시스템이 병행하는 배관에 미치는 영향)

  • Lee, H.G.;Ha, Y.C.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.285-287
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on parallel pipelines of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF

Anode Location of Distributed ICCP Systems for Mitigation of DC Traction Interference on Buried Pipelines (전철 간섭 대책용 분포형 외부전원시스템의 양극위치)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1660-1662
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the anode location of distributed impressed current cathodic protection systems for the mitigation of DC traction interference on buried pipelines using the simulation software CatPro. We can get a fix on the anode location.

  • PDF

Optimization of Conduction-cooled Pottier Current Leads (전도냉각형 펠티어 전류도입선의 최적화)

  • Jeong, Eun-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.764-771
    • /
    • 2005
  • A theoretical investigation for optimization of conduction-cooled Peltier current leads is undertaken. A Pottier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high Tc superconductor (HTS) lead in the order of decreasing thermoelectric tempera ture. Mathematical expression for the minimum heat flow per unit current crossing the TE metal interface and that flowing from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE-metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the 73 and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

Calorimetry for the Measurement of Heat Leak (열량법에 의한 열침입량의 계측)

  • 김동락;양형석;김도형;조승연;정원묵;이제묘
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.328-331
    • /
    • 2003
  • In this study, the experimental study based on calorimetry for terminal cryostat has been performed and evaluated. The experiments performed here were divided into two types, those are test without and with current lead. The former is intended for the evaluation of feasibility and precision of our calorimetry, the later for the application to terminal cryostat of our study. As a result, it was found that the calorimetry performed in this study could predict well the heat transfer rate into the terminal cryostat.

  • PDF

Methods of Improving Operational Reliability of Oil Well Casing

  • Sergey A. Dolgikh;Irek I. Mukhamatdinov
    • Corrosion Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Oil well casing leak is caused by contact of casing outer surface with formation electrolyte. It is usually associated with an aquifer with a high salt content or absence of a cement ring behind the casing. The only way to reduce external casing corrosion is through cathodic protection. Through cathodic polarization of casing structure, electron content in crystal lattice and electron density will increase, leading to a potential shift towards the cathodic region. At Tatneft enterprises, cathodic protection is carried out according to cluster and individual schemes. The main criterion for cathodic protection is the size of protective current. For a casing, the protective current is considered sufficient if measurements with a two-contact probe show that the electric current directed to the casing has eliminated all anode sites. To determine the value of required protective current, all methods are considered in this work. In addition, an analysis of all methods used to determine the minimum protective current of the casing is provided. Results show that the method of measuring potential drop along casing is one of the most reliable methods for determining the value of protective current.