• Title/Summary/Keyword: Leak Test

Search Result 257, Processing Time 0.024 seconds

Memory Leak Detection Using Adaptive Cyclic Memory Allocation (동적 순환 메모리 할당 기법을 이용한 메모리 누수 검출)

  • Lim, Woo-Sup;Han, Hwan-Soo;Lee, Sang-Won
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.10
    • /
    • pp.760-767
    • /
    • 2010
  • There are many memory leak detection tools. However, programmers, who develop very large programs, tend to avoid testing their programs with memory leak detection tools since these tools require runtime and space overheads. Thus, we present a memory leak detection technique which enables programmers to test their modules in their unit test phase with low overheads. To achieve this goal, we extend the existing cyclic memory allocation technique and evaluate our memory leak detection technique on a tiny DBMS. In our experiments, we find our tool has reasonably low runtime and space overheads and it reports only a small number of false positives.

Helium Leak Test for the PLS Storage Ring Chamber (포항가속기 저장링챔버의 헬륨누설검사)

  • Choi, M.H.;Kim, H.J.;Choi, W.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.31-38
    • /
    • 1993
  • The storage ring vacuum system for the Pohang Light Source (PLS) has been designed to maintain the vacuum pressure of $10^{-10}Torr$ which requires UHV welding to have helium leak rate less than $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$. In order to develop new technique (PLS) welding technique), a prototype vacuum chamber has been welded by using Tungsten Inert Gas welding method and all the welded joints have been tested with a non-destructive method, so called helium leak detection, to investigate the vacuum tightness of the weld joints. The test was performed with a detection limit of $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$ for helium and no detectable leaks were found for all the welded joints. Thus the performance of welding technique is proven to meet the criteria of helium leak rate required in the PLS Storage Ring. Both the principle and the procedure for the helium leak detection are also discussed.

  • PDF

A Study on the Applicability of Acrylic Water Leak Repair Materials used to Repair Cracks in Conduits and Underground Structures (관거 및 지하구조물 균열 보수에 사용되는 아크릴 누수 보수재의 적용성에 대한 연구)

  • Eunmi Lee;Kyungik Gil
    • Journal of Wetlands Research
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2024
  • Various injection materials, such as asphalt-based injection materials, urethane-based injection materials, cement- based injection materials, and acrylic-based injection materials, are used for the repair of aged conduits and underground structures with cracks. In this study, research was conducted on an environmentally friendly acrylic- based leak repair material that exhibits good curing properties even in humid conditions and stability in temperature fluctuations. To compare the performance of the improved acrylic leak repair material with the existing acrylate injection material, experiments were conducted using KS standard methods, including underwater length change rate tests, underwater leakage resistance tests, and chemical performance tests. The comparative experiments revealed that the improved acrylic leak repair material showed no changes in shrinkage due to humidity, temperature variations, or chemical reactions compared to the existing acrylate injection material. In the underwater resistance test, the improved acrylic leak repair material did not show any leakage. Additionally, to assess the environmental impact of the improved acrylic leak repair material, acute fish toxicity tests and acute oral toxicity tests were conducted, and the results showed no mortality and no specific concerns with the test specimens. The experimental results led to the conclusion that the improved acrylic leak repair material is considered to be superior in performance, environmentally safe, and harmless to the human body. Based on various experimental results, it is inferred that the improved acrylic leak repair material is suitable for use as a repair material for cracks in manholes and underground structures compared to the existing acrylate repair material. This study aims to propose valuable data for future technological development by evaluating the applicability of acrylic leak repair materials.

A Study on a Quality Characteristics of Pressure Leak Test of Process Piping for Offshore Plant (해양플랜트 프로세스 배관 Pressure Leak Test의 품질 특성에 관한 연구)

  • Park, Chang-Soo;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.429-437
    • /
    • 2018
  • The process gas piping of the offshore plant can cause a massive explosion if the gas leakage occurs during operation. For the purpose of precaution of gas leakage accident, an air pressure test is performed on the process equipment tests using a test pump as much as the power to the piping inner side, mix 99% nitrogen gas and 1% helium gas. The purpose of the air pressure test is to check the work conformity process by handling and regulation for initial piping process, assembly, installation of module, welding, center alignment of the pipes assembling flange gasket in an unrestrained free state. In this paper, the regulation of the problematic air pressure test was analyzed and the solution criteria were established. And leakage tests of existing equipment were performed applying these solution methods. As a result, it was confirmed that there was no problem.

The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test (열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

A Study on the Systematic Mechanical Integrity Evaluation Methods of Water-Cooled Generator Stator Windings (수냉각 발전기 고정자의 기계적 건전성 평가방법)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Wook-Ryun;Lee, Doo-Young;Choi, Hong-Il;Yeon, Se-Heum
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3059-3066
    • /
    • 2008
  • It is reported that the life of generator stator windings is expected about 30 years and a leak and water absorption phenomena can be progressed by fatigue, vibration, and corrosion. The water-cooled generator stator windings which were operated over 15 years are over 20 units and the mechanical problems such as leak and water absorption were found in the generator stator windings. In this paper, the systematic mechanical integrity evaluation methods which are applied to the water-cooled generator stator windings within the country are introduced.

  • PDF

Hermetic Characteristics of Negative PR (Negative PR의 기밀 특성)

  • Choi, Eui-Jung;Sun, Yong-Bin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.2 s.15
    • /
    • pp.33-36
    • /
    • 2006
  • Many issues arose to use the Pb-free solder as adhesive materials in MEMS ICs and packaging. Then this study for easy and simple sealing method using adhesive materials was carried out to maintain hermetic characteristic in MEMS Package. In this study, Hermetic characteristic using negative PR (XP SU-8 3050 NO-2) as adhesive at the interface of Si test coupon/glass substrate and Si test coupon/LTCC substrate was examined. For experiment, the dispenser pressure was 4 MPa and the $200\;{\mu}m{\Phi}$ syringe nozzle was used. 3.0 mm/sec as speed of dispensing and 0.13 mm as the gap between Si test coupon and nozzle was selected to machine condition. 1 min at $65^{\circ}C$ and 15 min at $95^{\circ}C$ as Soft bake, $200\;mj/cm^2$ expose in 365 nm wavelength as UV expose, 1 min at $65^{\circ}C$ and 6 min at $95^{\circ}C$ as Post expose bake, 60 min at $150^{\circ}C$ as hard bake were selected to activation condition of negative PR. Hermetic sealing was achieved at the Si test coupon/ glass substrate and Si test coupon/LTCC substrate. The leak rate of Si test coupon/glass substrate was $5.9{\times}10^{-8}mbar-l/sec$, and there was no effect by adhesive method. The leak rate of Si test coupon/LTCC substrate was $4.9{\times}10^{-8}mbar-l/sec$, and there was no effect by dispensing cycle. Better leak rate value could be achieved to use modified substrate which prevent PR flow, to increase UV expose energy and to use system that controls gap automatically with vision.

  • PDF

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

Cryogenic leak test of LOX pump static seals (산화제펌프 스태틱 실 극저온 기밀시험)

  • Park, Min-Joo;Jeon, Seong-Min;Yoon, Suk-Hwan;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.73-81
    • /
    • 2009
  • Casing leak tests using three kinds of static seals are performed by simulating test section for a 75 ton thrust class turbopump under ambient and cryogenic temperature environment. As results of application of Conical, PTFE, and C static seals to leak tests, even though they all work in normal temperature condition, only the PTFE and C static seals show good sealing performance in cryogenic condition. However, the Conical static seal fails because of the different thermal expansion rates due to the use of different materials in a LOX pump. It is found that unlike the PTFE and C static seals with sealing surfaces in axial direction, the sealing surface of the Conical static seal is in radial direction that may cause leak when the casings thermally shrink in radial direction. Especially, the C static seal reveals excellent sealing performance even for a used seal.

  • PDF

Improvement of Acoustic Emission Signal Processing Method and Source Location using Wavelet Transform (웨이블릿 변환을 이용한 음향방출 신호의 처리기법 개선 및 위치표정)

  • Kim, Dong-Hyun;Park, Il-Suh;Chung, Won-Yong;Park, Yong-Suk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.10-17
    • /
    • 2008
  • The purpose of this thesis is to reduce of error for source location through acoustic emission(AE) signal, generated elastic wave from crack growth to leak for facility diagnosis. Especially, in order to overcome noise from original signal, this paper proposed enhancement of source location by using noise reduction based on wavelet transform. To evaluate actual performance in experiments, Pencil Lead Break is used crack signal source on the aluminum plate and drain valve of air compressor is used as substitute pressure vessel to generate leak signal. In signal processing, wavelet shrinkage and soft threshold are used to discriminate signal source and then source location techniques have been effectively used with group velocity using material property and time difference between sensor using cross correlation. Source location for crack and leak test have some difference, but the result show that improved 30% with a average length within 10.46mm in crack test and improved 2% compare with average filter in leak test when we applied wavelet transform.

  • PDF