• 제목/요약/키워드: Leak Location Detection

검색결과 39건 처리시간 0.022초

배관계의 가스누설탐지를 위한 음향모델 연구 (A Study on an Acoustical Model for Gas Leak Detection in a Pipeline)

  • 양윤상;이동훈;고재필
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.91-96
    • /
    • 2014
  • An acoustical model for detecting the leak location in a buried gas pipeline has been developed. This model is divided into an experimental model for sound diagnosis, and a theoretical model for sound prediction, which is based on the transfer matrix method, representing the sound pressure and the volume velocity as state variables. The power spectrum is measured by attaching only one microphone to the closed end pipe. It has been shown that the response magnitude of acoustic pressure signals calculated by the acoustical model depends upon the thickness and diameter of a pinhole. The validity for the acoustical model has been verified through a comparison between the measured and calculated results.

저압확장파 검출을 통한 배관 누출 및 누출위치 예측 (Leak and Leak Point Prediction by Detecting Negative Pressure Wave in High Pressure Piping System)

  • 하태웅;하종만;김동혁;김영남
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.47-53
    • /
    • 2007
  • 고압 가스 배관망의 안전관리는 매우 중요한 문제로 배관의 외적 손상으로 구멍이 생길 경우 발생하는 누출은 폭발 및 환경오염을 포함한 막대한 경제적 손실을 야기할 수 있다. 누출 검지를 위한 PLDS(Pipeline leak detection system린 기술로 저압확장파 검지 기술이 적용되고 있으며 본 논문에서는 CFD++ 상용코드를 활용하여 배관 누출시 유동특성을 이론적으로 해석하여 저압확장파의 발생 메커니즘과 음속으로 확장되는 전파특성을 규명하였다. 또한 긴 배관망에 적용하기 위한 1차원 해석 방법을 제시하고 신뢰성을 CFD해석 결과로 검증하였다.

  • PDF

상수도관의 누수신호 특성 및 누수지점 추정에 관한 연구 (The leak signal characteristics and estimation of the leak location on water pipeline)

  • 박상봉;김기범;서지원;김주언;구자용
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.461-470
    • /
    • 2018
  • In this study, the leak signal was measured by using an accelerometer to analyze the basic data and methodology for the development of the leak point estimation method in the water supply pipe. The measured results were analyzed by frequency analysis and cross-correlation analysis for leakage signals, and the error range was compared and analyzed with the actual leak point distance. As a result, it was confirmed that the vibration intensity due to leakage from the water leakage point was attenuated according to the distance. In the case of the ductile iron casting used in the experiment, the intensity of the signal at the 945 Hz, 1,500 Hz, 2,300 Hz band was increased with the change of the pressure in the pipe at 4mm of leakage hole. Also, it was confirmed that as the water pressure increases, the intensity of the leak signal increases but the similarity of the signal decreases. The results of this study confirm that the accelerometer sensor can be used efficiently for leak detection and it can be used as a basic data for the analysis for the development of leak point estimation method in the future.

고압 배관망에서 배관 손상에 의한 누출 및 관내 저압확장파의 전파 특성 해석 (Analysis of Propagation of Negative Pressure Wave Due to Leak Through Damaged Hole in High Pressure Piping System)

  • 김왕연;하종만;하태웅
    • 한국유체기계학회 논문집
    • /
    • 제11권1호
    • /
    • pp.26-32
    • /
    • 2008
  • The safe operation of high pressure pipe line systems is of significant importance. Leaks due to faulty operation from the pipelines can lead to considerable product losses and to exposure of community to dangerous gases. There are several leak detection methods of pipeline network which have recently been suggested. The negative pressure wave detection technology, which has advantages of short time detection availability, accurate leaking location estimate capability and cost effective, is concentrated in this study. Theoretical analysis of the flow characteristics for leaking through a hole on the pipe wall has been performed by using Fluent 6.3, commercial CFD package. The results of 3-dimensional analysis near leaking hole confirm the occurrence of negative pressure wave, and the results of 2-dimensional analysis verify the characteristics of propagation of the wave which travels with speed equal to the speed of sound in the pipeline contents. Characteristics of leakage and pressure in a pipe with a hole have been analyzed for the various pipe and hole sizes.

시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구 (Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship)

  • 황현규;신동호;김헌희;이정형
    • 해양환경안전학회지
    • /
    • 제28권6호
    • /
    • pp.1044-1053
    • /
    • 2022
  • 시간영역반사계(TDR)는 케이블의 물리적 결함을 검사하는 기법이며 누수 탐지 분야로의 응용영역을 확대하고 있다. 본 연구는 시간영역반사계 기법을 활용하여 선박 기관실 해수 배관의 누설 감지용 케이블형 센서를 개발하였다. 케이블 센서의 형상은 꼬임형상과 흡습부재를 이용하여 제작하였으며 개발된 센서의 누수 감지 여부와 위치 탐지 가능성을 확인하였다. 개발된 센서는 실제 배관 시험 장치에 부착하여 평가하였으며 해수 누설에 따른 다양한 TDR 신호를 취득하였다. 센서는 꼬임횟수, 피복 두께를 변수로 하여 제작하였으며 TDR 신호에 미치는 효과를 분석하였다. 실험 결과, 꼬임형 센서는 평행한 띠 형상의 센서에 비해 평활한 신호 취득이 가능하였으며 최적 꼬임 횟수는 단위길이 당 10회 이상인 것으로 나타났다. 절연 피복두께의 경우 적정 민감도 확보가 가능한 절연 피복부재의 두께는 도선직경의 80%~120%로 확인되었다. 누수 위치 추정을 위해 회귀분석 실시 결과, 결정계수는 0.9998로 실제 누설 위치와 높은 상관관계를 나타내었다. 결과적으로 제안된 TDR 기반의 누수 감지용 꼬임형 센서는 해수 배관 시스템의 누수 감시 센서로의 충분한 적용성을 확인하였다.

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

Macro fiber composite (MFC) 센서를 이용한 음향방출 기술 기반 배관 누수 감지 시스템 (Acoustic Emission (AE) Technology-based Leak Detection System Using Macro-fiber Composite (MFC) Sensor)

  • 박재현;이시맥;이범주;김선주;유형민
    • Composites Research
    • /
    • 제36권6호
    • /
    • pp.429-434
    • /
    • 2023
  • 본 연구에서는 기존 배관 가스 누출 감지에 사용되던 음향방출 센서가 실시간 모니터링에 적용될 때 발생할 수 있는 문제들을 개선하기 위해, Macro-fiber composite (MFC) 트랜스듀서를 음향방출 센서로 사용하여 가스 누출 감지 시스템에 적용하였다. 적용 전 MFC의 구조를 최적화하기 위해 구조해석을 진행하여 제작하였고, 그 결과 MFC가 가지는 유연성으로 굴곡진 배관에 잘 밀착되어 AE 신호를 문제없이 수신할 수 있었다. AE 신호 분석 결과 고압 누출, 저압 누출 모두 파라미터 값 변화에 유의미한 결과를 보였으며, 특히, FFT 그래프의 파라미터에서 고압 누출의 경우 누출이 없는 경우 대비 120~626%의 변화량, 저압 누출의 경우 9~22%의 변화량을 보였다. 또한, 누출 발생 부위에서의 거리에 따라, 거리가 멀수록 이러한 파라미터 변화량이 줄어드는 경향을 보여, 추후 파라미터 변화량 감지를 통해 누출 감지가 가능할 뿐만 아니라, 변화량으로부터 누출 발생 위치를 파악할 수 있을 것으로 보인다.

스마트폰을 이용한 가스검출시스템 및 검출 방법연구 (System and method for detecting gas using smart-phone)

  • 방용기;강경식
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.129-137
    • /
    • 2015
  • This study is in regard to the gas detection system and gas detection method utilizing smart phone. This study includes; 1) the sensor module attached to the smart phone to detect and measure flammable gas or toxic gas; and 2) gas detection APP which is installed inside the smart phone and recognizes the user information and location information automatically by reading RFID tag indicating the user or the location to detect gas through the contact area where RFID and blue tooth reader is installed inside of the above mentioned smart phone, and then measures the combustible gas or toxic gas by operating above mentioned sensor module and obtains the data thus measured, and above mentioned smart phone is characterized by its transmission of the above mentioned user information, location information and measured data which are obtained by above mentioned gas detecting APP to operation server via communication network. With this, reliability for the location detecting gas by the user, the result of the measurement, etc. can be secured. Furthermore, this provides the effect of preventing artificial manipulation at the time of input which is associated with the identification of the user to be measured by utilizing removable sensor module and application or the mistake resulted from wrong input by the user. In addition, by transmitting the measured data from the sensor module carrying out gas detection to operation server, this provides the effect of making it possible to process the data thus collected to a specialized data for combustible gas or toxic gas.

목재 섬유판의 음향방출 위치표정과 재료 특성 평가 (Acoustic Emission Source Location and Material Characterization Evaluation of Fiberboards)

  • 노승남;박익근;서성원;김용권
    • 한국공작기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.96-102
    • /
    • 2005
  • Acoustic Emission(AE) technique has been applied to not only material characterization evaluation but also on-line monitoring of the structural integrity. The AE source location technique is very important to identify the source, such as crack, leak detection. Since the AE waveforms obtained from sensors are very difficult to distinguish the defect signals, therefore, it is necessary to consider the signal analysis of the transient wave-form. In this study, we have divided the region of interest into a set finite elements, and calculated the arrival time differences between sensors by using the velocities at every degree from 0 to 90. A new technique for the source location of acoustic emission in fiberboard plates has been studied by introducing Wavelet Transform(WT) do-noising technique. WT is a powerful tool for processing transient signals with temporally varying spectra. If the WT de-noising was employed, we could successfully filter out the errors of source location in fiberboard plates by arrival time difference method. The accuracy of source location appeared to be significantly improved.