• 제목/요약/키워드: Lead storage battery

검색결과 63건 처리시간 0.032초

연 노출 근로자들의 혈장 δ - aminolevulinic acid 량과 연 노출 지표들과의 관련성 (The Relationships between Plasma δ - aminolevulinic acid Concentration and Lead Exposure Indices in Lead Workers)

  • 김진호;안규동;이성수;황규윤;김용배;이병국
    • 한국산업보건학회지
    • /
    • 제10권2호
    • /
    • pp.165-172
    • /
    • 2000
  • This study was carried out to investigate relationship between plasma $\delta$ - aminolevulinic acid (ALAP) and lead exposure indices in exposure to lead. The subjects were 218 male workers in 2 storage battery companies and 2 secondary smelting companies. Blood lead(PbB), blood zinc-protoporphyrin( ZPP), urinary $\delta$ - aminolevulinic acid (ALAU), hemoglobin(Hb), and hematocrit(Hct) were measured as lead exposure indices. The results were as follows, 1. The means of blood lead and blood ZPP concentration of subjects were $27.2{\pm}14.0{\mu}g/d{\ell}$ and $55.1{\pm}47.6{\mu}g/d{\ell}$, respectively. The means of plasma $\delta$ - ALA and urinary $\delta$ - ALA concentration were $18.9{\pm}25.1{\mu}g/d{\ell}$ and $2.1{\pm}4.6mg/{\ell}$, respectively. 2. The concentration of ALAP was $11.2{\mu}g/{\ell}$ for below $20{\mu}g/d{\ell}$ PbB, $12.8{\mu}g/{\ell}$ for from $21-40{\mu}g/d{\ell}$ PbB, and $51.2{\mu}g/{\ell}$ for over $40{\mu}g/d{\ell}$ PbB, respectively. 3. ALAP was significantly correlated with ALAU(r=0.829, p<0.01), ZPP(r=0.724, p<0.01) and PbB(r=0.552, p<0.01).

  • PDF

연 노출 근로자들의 ALAD genotype에 따른 연 노출지표 및 증상과의 관련성 (Relationship on the lead exposure indices and symptoms by ALAD genotype in lead worker)

  • 안규동;이종천;조광성;김진호;이성수;이병국
    • 한국산업보건학회지
    • /
    • 제11권2호
    • /
    • pp.111-117
    • /
    • 2001
  • A cross-sectional study was performed to evaluate associations between lead biomarkers, lead-related symptoms, and ${\delta}$-aminolevulinic acid dehydratase (ALAD) genotype among 598 lead workers and 144 control office workers in storage battery industries, secondary smelting and litharge making industries. Lead inhibits the second enzymes, ALAD, in the heme synthesis pathway. ALAD gene, which codes for one of three isozymic proteins (termed ALAD1-1, ALAD1-2, and ALAD2-2), seems to modify the toxicokinetics of lead. The result as follows; The percents of total workers whose genotype of ALAD1-1 and ALAD1-2 were 88.4% and 11.6%, respectively. The zinc protoporphyrin in blood (ZPP) and ${\delta}$-aminolevulinic acid in urine (ALAU) of lead workers with ALAD1-2 were significantly lower than those of lead workers with ALAD1-1, but there were no significant difference between two genotype for blood lead, age, and work duration. The proportion of ALAD1-2 genotype in control office workers was 13.2%. The proportions of ALAD1-2 genotype of lead workers were 14.0%(their mean air lead level below $0.024mg/m^3$), 10.4%($0.025-0.049mg/m^3$), 11.8%($0.050-0.099mg/m^3$), and 9.4%(above $0.100mg/m^3$), respectively. In the logistic analysis of 15 lead related symptoms, 'arthralgia'(S7) symptom of ALAD1-2 was significantly lower (OR=0.481; 95% CI=0.248-0.932) than that of ALAD1-1, but 'feeling of irritation'(S11) of ALAD1-2 was significantly higher(OR=1.636; 95% CI=1.035-2.586) than that of ALAD1-1 after controlling possible confounder (blood lead, work duration, smoking and drinking habit).

  • PDF

고온 초전도 SMES용 전도냉각시스템 특성시험 (Test of the Conduction Cooling System for HTS SMES)

  • 염한길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.62-66
    • /
    • 2008
  • The characteristic of the superconducting magnetic energy storage(SMES) system is faster response, longer life time, more economical, and environment friendly than other uninterruptible power supply(UPS) using battery. So, the SMES system can be used to develop methods for improving power quality where a short interruption of power could lead to a long and costly shutdown. Recently, cryogen free SMES has developed using BSCCO(Bismuth Strontium Calcium Copper Oxide) wire. We fabricated and tested the conduction cooling system for the 600 kJ class HTS SMES. The experiment was accomplished for the simulation coils. The simulation coils were made of aluminium, it is equivalent to thermal mass of 600 kJ HTS SMES coil. The coil is cooled with two GM coolers through the copper conduction bar. In this paper, we report that the test results of cool-down and heat loads characteristics of the simulation coils. The developed conduction cooling system adapted to 600 kJ HTS SMES system and cope with the unexpected sudden heat impact, too.

Structural Evolution of Layered $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ upon Electrochemical Cycling in a Li Rechargeable Battery

  • 홍지현;서동화;김성욱;권혁조;박영욱;강기석
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.37.2-37.2
    • /
    • 2010
  • Recently $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ has been consistently examined and investigated by scientists because of its high lithium storage capacity, which exceeds beyond the conventional theoretical capacity based on conventional chemical concepts. Consequently, $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ is considered as one of the most promising cathode candidates for next generation in Li rechargeable batteries. Yet the mechanism and the origin of the overcapacity have not been clarified. Previously, many authors have demonstrated simultaneous oxygen evolution during the first delithiation. However, it may only explain the high capacity of the first charge process, and not of the subsequent cycles. In this work, we report a clarified interpretation of the structural evolution of $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$, which is the key element in understanding its anomalously high capacity. We identify how the structural evolution of $Li_{1.2}Ni_{0.2}Mn_{0.6}O_2$ occurs upon the electrochemical cycling through careful study of electrochemical profiles, ex-situ X-ray diffraction (XRD), HR-TEM, Raman spectroscopy, and first principles calculation. Moreover, we successfully separated the structural change at subsequent cycles (mainly cation rearrangement) from the first charge process (mainly oxygen evolution with Li extraction) by intentionally synthesizing sample with large particle size. Consequently, the intermediate states of structural evolution could be well resolved. All observations made through various tools lead to the result that spinel-like cation arrangement and lithium environment are created and embedded in layered framework during repeated electrochemical cycling.

  • PDF

연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화 (The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers)

  • 김용배;안현철;황보영;리갑수;이성수;안규동;이병국
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권4호
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

상용자동차용 직·병렬 AGM 배터리 시스템의 충·방전 거동 모델링 (Modeling of the charge and discharge behavior of the 2S2P(2 series-2 parallel) AGM battery system for commercial vehicles)

  • 이정빈;김의성;이재신;신치범
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.346-355
    • /
    • 2012
  • 최근 전 세계가 환경문제와 에너지 자원 고갈 문제에 대해 관심을 집중하고 있다. 이런 문제들을 해결하기 위한 여러 가지 방법들 중 하나가 하이브리드자동차(HEVs)이다. 그래서 하이브리드자동차 기술에 대한 사람들의 관심이 높아지고 있다. 하이브리드 자동차의 에너지 저장 시스템의 후보들은 AGM 배터리, Ni-MH 배터리 및 리튬배터리 등이다. AGM 배터리는 상대적으로 낮은 가격, 높은 충전 효율, 낮은 자가 방전 및 높은 안전성 등이 장점이다. 상용자동차에 하이브리드 자동차 시스템을 적용하기 위해서는 4개의 AGM 배터리를 2개의 직렬과 2개의 병렬로 연결해야한다. 본 연구에서는 상용차용으로 사용될 직 병렬로 연결되어 있는 AGM 배터리 시스템의 충 방전 특성을 예측하기 위하여 AGM 배터리의 충 방전 모델링을 수행하였다. AGM 배터리의 충 방전 모델링을 위해 내부에서 일어나는 전기화학 반응, 전하 보전과 물질 보존 법칙을 통해 배터리의 지배방정식으로 세웠다. 모델링 결과의 정확성을 검증하기 위해 다양한 조건에서의 실험결과와 비교하였다.

Semi-Gel 전해액이 전력저장용 배터리에 미치는 영향에 관한 연구 (A Study on the Effects of Semi-Gel Electrolyte in Electricity Storage Battery)

  • 정순욱;구본근
    • 한국응용과학기술학회지
    • /
    • 제29권2호
    • /
    • pp.193-198
    • /
    • 2012
  • 태양광 또는 풍력을 이용해 발생된 에너지를 효율적으로 저장과 사용을 위한 납 축전지의 성능을 향상 시키기 위해 전해액을 Semi-gel화 하여 납축전지에 적용하여 시험한 결과, 다음과 같은 결과를 얻었다. Semi-gel 전해액은 silica를 5wt.% 혼합한 전해액이 1시간 30분경과 시 gel화가 시작되었다. 이는 전해액이 격리판과 극판 활물질 내부까지 완전히 스며들기에 충분한 시간으로 가장 적정한 gel화 시간을 나타내었다. Semi-gel 전해액을 사용한 납축전지와 액상 전해액을 사용한 납축전지의 방전 성능을 비교한 결과, 저율방전 성능은 semi-gel전해액이, 고율방전 성능은 액상 전해액이 높은 성능을 나타내었다. 이는 gel 전해액의 경우 액상 전해액에 비해 반응속도가 느려 고율방전 성능이 낮은 것으로 나타내었다. 수명성능을 DOD 10%, DOD 100%로 시험한 결과, 5%-silica 전해액이 액상 전해액을 사용한 납축전지에 비해 우수한 수명 성능을 나타내었다. 이는 Semi-gel상 태의 전해액이 납축전지 내부 화학반응 시 발생하는 gas의 재결합 효율을 높여 전해액 감액량이 최소화로 한 결과로 수명성능에서 큰 차이를 나타내었다. 태양광, 풍력 등과 같은 에너지 저장 효율을 높이고, 수명성능을 향상시키기 위해 전해액에 5%-silica전해액을 사용하면 전해액의 감액량이 최소로 되어 DOD 100% 수명시험의 경우 4.8%, DOD 10% 수명시험의 경우 20%의 수명성능이 향상되었다.

슈퍼커패시터를 적용한 에너지 저장시스템 설계에 관한 연구 (The Research On the Energy Storage System Using SuperCapacitor)

  • 김일송
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권11호
    • /
    • pp.215-222
    • /
    • 2018
  • 본 논문에서는 슈퍼커패시터를 적용한 에너지 저장장치에 대해서 연구하였다. 납축전지등을 사용하였던 기존방식과는 다르게 슈퍼커패시터를 사용하여 고출력을 달성할 수 있으며, 이러한 특징으로 인하여 연구된 저장장치는 비상전원용 전력을 공급할 수 있을 뿐만 아니라, 전력품질 개선이나 짧은 순간에 큰 출력을 요구하는 고속 기동용 모터등의 전원시스템으로도 사용이 가능한 장점이 있다. 에너지변환 시스템은 양방향 인버터와 컨버터로 구성되어 고속, 고출력의 충전, 방전을 수행할 수 있는 장점도 있다. 양방향 인버터를 이용한 two loop 제어기 설계 방법이 제시되었고, 실험과 제작을 통해 설계 방법의 정합성을 입증하였다. 설계 순서는 먼저 상태공간 평균화 기법과 Decoupling 기법을 이용하여 선형화된 전달함수를 계산하였다. 다음 20% 오버슈트와 안정시간을 만족시키는 전류 제어기 설계를 한 후에 오버슈트 없는 전압과 10배 이상 느린 안정시간을 가지는 전압제어기를 설계한 후 단위계단응답 커브를 통해 원하는 설계특성이 나오는 지를 확인하는 과정으로 이루어진다. 설계된 제어기들은 계통과 단위 역률을 이루며 제어되기 때문에 전력품질 향상을 이룰 수 있으며, 빠른 응답특성과 정상상태 오차를 0으로 만들 수 있는 우수한 제어특성을 가지고 있음을 확인할 수 있었다.

축전지공장 근로자들의 혈중 연농도에 대한 코호트 관찰 (Cohort Observation of Blood Lead Concentration of Storage Battery Workers)

  • 김창윤;김정만;한구웅;박정한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제23권3호
    • /
    • pp.324-337
    • /
    • 1990
  • 축전지 공장의 환경과 근로자들의 개인 위생의 개선 조치가 근로자의 혈중 연농도에 어떤 영향을 미치는지를 관찰하기 위하여 새로 설립된 축전지 공장의 생산직 근로자 116명을 대상으로 채용시 혈중 연농도를 측정하고 1987년 2월부터 약 3개월 간격으로 $12{\sim}18$개월간 추적 관찰하였다. 관찰기관 중 작업환경 및 근로자 개인위생의 개선조치를 시행하였고 1987년 8월부터 6개월 간격으로 3회 작업장내 공기중 연농도를 측정하였다. 또 사무직 근로자 40명을 대조군으로 선정하여 그들의 혈중 연농도의 변화를 관찰하였다. 작업환경 개선은 국소배기장치 설치와 바닥의 진공청소였고 개인위생 개선조치는 매일 작업복 세탁, 퇴근시 샤워, 식사 전 손씻기, 작업장내 흡연 및 음식섭취 금지, 그리고 마스크 착용이었다. 대조군 40명 중 6개월까지 혈중 연농도의 관찰이 가능했던 27명에서 채용시 혈중 연농도가 $21.97{\pm}3.36{\mu}g/dl$이고 6개월후 $22.75{\pm}3.38{\mu}g/dl$로서 유의한 증가는 없었다. 공장이 가동되기 전에 입사한 A군은 폭로 전 혈중 연농도가 $20.49{\pm}3.84{\mu}g/dl$였고 폭로시작 3개월 후에 $23.90{\pm}5.30{\mu}g/dl$로 유의한 증가를 보였으며(p<0.01), 6개월 후(개선조치 1개월후)에는 $28.84{\pm}5.76{\mu}g/dl$로 더욱 증가되었으나 그후 4회 측정치는 $26.83{\sim}28.28{\mu}g/dl$로 더 이상 증가하지 않았다. 공장이 가동된 후 개선조치가 시행되기 전에 입사한 B군의 경우 폭로전 혈중 연농도가 $16.58{\pm}4/53{\mu}g/dl$였고 3개월후(개선조치 1개월후)에 $28.82{\pm}5.66{\mu}g/dl$로 급격히 증가했으며(p<0.01), 그 후 4회 측정치도 $26.46{\sim}28.54{\mu}g/dl$로 더이상 증가하지 않았다. 개선조치가 시행된 후 입사한 C군에서는 채용시 혈중 연농도가 $19.45{\pm}3.34{\mu}g/dl$였고 3개월후의 혈중 연농도가 $22.70{\pm}4.55{\mu}g/dl$로 유의한 증가를 보였고(p<0.01), 6개월에 $23.68{\pm}4.18{\mu}g/dl$, 9개월에 $25.42{\pm}3.60{\mu}g/dl$로 서서히 증가하는 경향을 보였다. 1987년 8원부터 6개월 간격으로 3회 작업환경을 측정하고 작업장의 공기중 연농도에 따라 4개부서로 구분하여 그 성적을 보면 제I부서는 $0.365mg/m^3$였으나, 작업환경 개선조치 후 각각 $0.216mg/m^3,\;0.208mg/m^3$로 감소되었고, 제II부서는 $0.232mg/m^3$였는데 개선조치후 $0.148mg/m^3,\;0.120mg/m^3$였으며, 작업환경 개선 조치후 측정한 제III부서는 1988년 1월, 8월에 각각 $0.124mg/m^3,\;0.091mg/m^3$였고 제IV부서(이동부서)는 1988년 8월에 $0.110mg/m^3$로 III, IV부서가 I, II부서에 비해 낮았다. 각 부서별 비교에서 A군과 B군의 혈중 연농도는 공기중 연농도와 비례하지 않는 결과를 보여 작업환경이 제일 나쁜 제 I부서에서 오히려 혈중 연농도가 낮고 작업환경이 좋은 제III부서에서 더 급격히 혈중 연농도가 증가하였다. C군은 제 I부서의 혈중 연농도가 제일 높았고 이동부서인 제IV부서에서 제일 낮아 공기중 연농도와 혈중 연농도 사이에 일정한 관련성을 나타내지 않았다. 이상의 결과로 보아 연취급 근로자의 모니터링은 공기중 연농도보다 혈중 연농도의 측정이 타당하며 작업환경개선도 중요하지만 개인위생에 대한 개선조치가 오히려 더 효과적이라 생각된다.

  • PDF

분산전원이 연계된 배전선로의 운영시스템 설계 (Operation System Design of Distribution Feeder with Distributed Energy Resources)

  • 김성만;장영학;김경훈;김슬기;문채주
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1183-1194
    • /
    • 2021
  • 전통적으로 전력시스템은 공급체계의 말단에 있는 소비자의 위치에서 보면 중앙집중화된 구조를 갖고 있다. 그러나 최근 수 십년간 지붕형 태양광, 영농형 태양광, 소형 풍력터빈, 배터리저장장치 및 스마트 가전품과 같은 분산에너지원의 등장을 보아왔다. 분산에너지원의 등장에 따라 배전계통 운전원의 역할도 확장된다. 확장된 분산전원의 진출은 배전망이나 송전망의 전통적인 계획과 운영에 영향을 주는 전력계통의 역조류와 예측성을 어렵게 할 수 있다. 이는 전형적인 계통계획, 정비 및 망관리, 정전할당 등 배전계통 운전원이 갖는 기능이 변경되어야 할 필요성을 증폭시킨다. 이 연구의 목적은 다중 분산전원을 갖는 미래 배전운전시스템을 설계하고 제안된 배전시스템 모델을 HILS로 구현 및 검증하는 것이다. 시험결과를 보면 제안된 배전시스템이 정상 영역에서 운전되고 배전선로 손실이 감소된다는 것을 보여준다.