• Title/Summary/Keyword: Lead screw

Search Result 71, Processing Time 0.026 seconds

High Speed Tool Feed System by the Mechanism of Ball Screw and Servo Motor (볼 나사와 서보모터 메커니즘에 의한 고속 TOOL 이송장치)

  • 김성식;김경석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.76-82
    • /
    • 1998
  • In this study, the Ball screw and Servo motor Mechanism is considered as a High Speed Tool Feed System for the machining of a piston of a reciprocating engine. For the machining of a piston, that shapes oval, high speed servo mechanism is needed as a positioning of a cutting tool, and the stroke of tool is 0.1 mm ~ 1 mm. Ball screw and servo motor Mechanism is available very much because this mechanism is used widely in general machine. This Mechanism has been designed with the use of the decrease in mass and partial wear of the ball screw for high speed positioning of tool. Also the periodic learning control method with the inverse transfer function compensation has been applied to the positioning control for the high accuracy positioning of tool. These applications lead the achievement of the machining of a piston with an accuracy of 5${\mu}{\textrm}{m}$ at 2500 rpm in CNC turning.

  • PDF

Review of Mathematical Models in Performance Calculation of Screw Compressors

  • Stosic, Nikola;Smith, Ian K.;Kovacevic, Ahmed;Mujic, Elvedin
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.271-288
    • /
    • 2011
  • The mathematical modelling of screw compressor processes and its implementation in their design began about 30 years ago with the publication of several pioneering papers on this topic, mainly at Purdue Compressor Conferences. This led to the gradual introduction of computer aided design, which, in turn, resulted in huge improvements in these machines, especially in oil-flooded air compressors, where the market is very competitive. A review of progress in such methods is presented in this paper together with their application in successful compressor designs. As a result of their introduction, even small details are now considered significant in efforts to improve performance and reduce costs. Despite this, there are still possibilities to introduce new methods and procedures for improved rotor profiles, design optimisation for each specified duty and specialized compressor design, all of which can lead to a better product and new areas of application. A review of methods and procedures which lead to modern screw compressor practice is presented in this paper. This paper is intended to give a cross section through activities being done in mathematical modelling of screw compressor process through last five decades. It is expected to serve as a basis for further contributions in the area and as a challenge to the forthcoming generations of scientists and engineers to concentrate their efforts in finding future and more extended approaches and submit their contributions.

Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process

  • Sung, Min-Jae;Kim, Kyoung-Tae;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.503-508
    • /
    • 2018
  • Objective : Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation. Methods : We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age${\pm}$standard deviation, $45.8{\pm}14.2years$). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured. Results : The mean width of the apical dens tip was $9.6{\pm}1.1mm$. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were $39.2{\pm}2.6mm$ and $36.6{\pm}2.4mm$. The safe margin beyond apical dens tip to ventral dura was $7.7{\pm}1.7mm$. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to $2.1{\pm}3.2mm$, which was statistically significant (p<0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age. Conclusion : Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater.

Linear Electric Motors in Machining Processes

  • Gieras, Jacek F.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.380-389
    • /
    • 2013
  • Application of linear electric motors to automation of manufacturing processes, gantry robots, machining processes, machining centers, additive manufacturing and laser scribing has been discussed. The paper focuses on replacement of ball lead screw mechanisms with linear electric motors, linear motor driven positioning stages, linear motor driven gantries, machining centers, machining of large objects and industrial lasers. The best linear electric motors for application to machining processes are permanent magnet (PM) linear synchronous motors (LSMs), especially those without PMs in the reaction tail, e.g., high thrust density linear (HDL) LSMs and PM flux switching (FS) LSMs.

Arteriovenous Fistula after C1-2 Posterior Transarticular Screw Fixation - Case Report - (환축추체 후방 나사고정술 후 생긴 동정맥루)

  • Lee, Hyuk Gi;Cho, Jae Hoon;Lee, Sung Lak;Kang, Dong Gee;Kim, Sang Chul;Kim, Yong Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.280-285
    • /
    • 2000
  • Posterior transarticular screw fixation for atlantoaxial instability due to trauma or rheumatoid arthritis provides immediate rigid fixation of the C1-2 vertebral segment while preserving motion between the occiput and C1. This technique provides more resistance to translational and rotational forces than wiring technique. However, the technique of transarticular screw fixation is inherently demanding because of the complex anatomy of the occipitocervical region and vertebral artery(VA) at risk for arterial damage. VA injury may lead to serious subsequent neurological deficits and possibly death from bilateral VA injury. We report a case of a vertebral artery-to-epidural venous plexus fistula after posterior transarticular screw fixation which was treated with balloon occlusion.

  • PDF

Seismic performances of RC columns reinforced with screw ribbed reinforcements connected by mechanical splice

  • Lee, Se-Jung;Lee, Deuck Hang;Kim, Kang Su;Oh, Jae-Yuel;Park, Min-Kook;Yang, Il-Seung
    • Computers and Concrete
    • /
    • v.12 no.2
    • /
    • pp.131-149
    • /
    • 2013
  • Various types of reinforcement splicing methods have been developed and implemented in reinforced concrete construction projects for achieving the continuity of reinforcements. Due to the complicated reinforcement arrangements and the difficulties in securing bar spacing, the traditional lap splicing method, which has been widely used in reinforced concrete constructions, often shows low constructability and difficulties in quality control. Also, lap spliced regions are likely to be over-reinforced, which may not be desirable in seismic design. On the other hand, mechanical splicing methods can offer simple and clear arrangements of reinforcement. In order to utilize the couplers for the ribbed-deformed bars, however, additional screw processing at the ends of reinforcing bars is typically required, which often lead to performance degradations of reinforced concrete members due to the lack of workmanship in screw processing or in adjusting the length of reinforcing bars. On the contrary, the use of screw-ribbed reinforcements can easily solve these issues on the mechanical splicing methods, because it does not require the screw process on the bar. In this study, the mechanical coupler suitable for the screw-ribbed reinforcements has been developed, in which any gap between the reinforcements and sleeve device can be removed by grouting high-flow inorganic mortar. This study presents the uniaxial tension tests on the screw-ribbed reinforcement with the mechanical sleeve devices and the cyclic loading tests on RC columns with the developed coupler. The test results show that the mechanical sleeve connection developed in this study has an excellent splicing performance, and that it is applicable to reinforced concrete columns with a proper confinement by hoop reinforcement.

Screw Vacuum Pump의 Screw 리드의 변화에 따른 성능평가 연구

  • Gang, Sang-Baek;No, Yeong-Ho;Yu, Jae-Gyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.153-153
    • /
    • 2014
  • 건식 진공펌프(dry vacuum pump)는 기계적 저진공펌프 중 펌프 내부의 기체 배기통로에 오일을 전혀 사용하지 않는 펌프의 통칭으로써, 대개 비접촉형으로 여러 형태의 회전자가 고속으로 회전하면서 흡기구로부터 들어온 기체를 압축해 배기를 한다. 비접촉형에는 루츠(roots)형, 클로(claw)형, 스크류(screw)형, 스크롤(scroll)형 등이 있다. 그 중 스크류형 펌프는 큰 배기속도를 갖는 펌프의 설계에 유리하고 높은 운용온도가 가능하여 다수공정에 쉽게 적용할 수 있는 장점이 있다. 그러나 1단 펌프 구성을 갖게 됨에 따라 루츠형 대비 높은 소비전력 특성을 보이는 약점을 가지고 있다. 본 논문에서는 건식 진공펌프 중의 하나인 스크류형 진공펌프에 대하여, 기본적인 1단 펌프 구성에 스크류 리드(lead)의 변화를 주어 기존의 똑같은 리드의 스크류 진공펌프에 대한 소비전력 및 배기구 온도 등 스크류 형상에 대한 성능평가 연구를 진행 하고자 한다.

  • PDF

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

Surface Finishing of Ballscrew by Abrasive Wheel Brush (연마재함유 휠브러쉬에 의한 볼스크류 연마기술)

  • 이응숙;김재구;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.1049-1052
    • /
    • 1997
  • The pupose of this study on the surface finishing is to examine the performance of brushing as a means of reducing the surface roughness of the precision theaded shafts in ball screw assemblies. Ball screws provide superior performance compared to other types of screw feeds in terms of static and dynamic rolling resistance,backlash,and wear characteristics. The Reduction of the surface roughness of the lead shaft in ball screw assembiles is essential for precision movement,high speed/low noise tracel, and for low wear/long life. To reduce machine dependent errors that would influence the surface roughness compared with other lapping or polishing techniques,experiments will be performed using special wire brushes to polish precision ground shafts. The best results were obtained using the Al /sab 2/O /sab3/ brushes, with the Al /sab 2/O /sab3/ #500 grit brush producing a surface finish of approximately 0.7 .mu.m, and the Al /sab 2/O /sab3/ #600 grit producing a surface finish of approximately 0.8 .mu.m. Both of these results were produced at the highest wheel polishing speed of 3520 rpm. The SiC #500 brush produced a surface roughness of approximately 1 .mu.m at 3520 rpm.

  • PDF

Percutaneous screw fixation and external stabilization as definitive surgical intervention for a pelvic ring injury combined with an acetabular fracture in the acute phase of polytrauma in Korea: a case report

  • Hohyoung Lee;Myung-Rae Cho;Suk-Kyoon Song;Euisun Yoon;Sungho Lee
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.298-303
    • /
    • 2023
  • Unstable pelvic ring injuries are potentially life-threatening and associated with high mortality and complication rates in polytrauma patients. The most common cause of death in patients with pelvic ring injuries is massive bleeding. With resuscitation, external fixation can be performed as a temporary stabilization procedure for hemostasis in unstable pelvic fractures. Internal fixation following temporary external fixation of the pelvic ring yields superior and more reliable stabilization. However, a time-consuming extended approach to open reduction and internal fixation of the pelvic ring is frequently precluded by an unacceptable physiologic condition and/or concomitant injuries in patients with multiple injuries. Conservative treatment may lead to pelvic ring deformity, which is associated with various functional disabilities such as limb length discrepancy, gait disturbance, and sitting intolerance. Therefore, if the patient is not expected to be suitable for additional surgery due to a poor expected physiologic condition, definitive external fixation in combination with various percutaneous screw fixations to restore the pelvic ring should be considered in the acute phase. Herein, we report a case of unstable pelvic ring injury successfully treated with definitive external fixation and percutaneous screw fixation in the acute phase in a severely injured polytrauma patient.