• Title/Summary/Keyword: Lead in air

Search Result 621, Processing Time 0.029 seconds

Experimental study on applicability of Air-Curtain system in train fire at subsea tunnel rescue station (해저터널 열차 화재 시 구난역 에어커튼 시스템의 성능에 관한 실험 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Visibility is very poor in tunnel fire because of confined space where the fire may easily lead to the mass casuality incident because of fast smoke spread. In this test, air curtain and the fan were installed at rescue station in a bid to make use of rescue station in safe way during the train fire in undersea tunnel and a full-scale fire test was conducted to identify the applicability of air curtain system. Air curtain system was installed at a real rescue station and the test was continued for 2 minutes till heptane which was used as fire source was completely burned out. When air curtain was working, difference in temperature between inside and outside the platform was $160^{\circ}C$ and carbon monoxide measured inside the platform was less than the case of no air curtain system by 160 ppm. Thus a full-scale fire test demonstrated that the air curtain system installed at rescue station in undersea tunnel was able to effectively block the heat and smoke generated from the fire.

A Study on the Contents of Soluble Sulfur and Heavy Metals in the Leaves of the Roadside Tree in Seoul Area (서울시내 가로수목의 수용성유황 및 중금속 함량에 관한 연구)

  • 김면섭;이광국
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 1988
  • This study was carried out to measure the contents of soluble sulfur and heavy metals in the leaves of roadside tree at 34 sampling sites of Seoul area from the Sep. 1 to Sep. 30 during 1985 and 1986. The results were as follows; 1. Average contents of soluble sulfur at all sampling sites were; Plantanus orientalis 0.474%, Ginkgobioloba 0.562%, and Salix pseudolasiogyne 0.566%. 2. Correlation between sulfur dioxide concentration in the air and soluble sulfur in the leaves by area were; Green belt area R = 0.985, Residential area R = 0.856, Commercial area R = 0.668, Industrial area R = 0.886. Correlation by species were ; Platanus orientalis R = 0.817, Ginkgobiloba R = 0.771, Salix pseudo-lasiogyne R = 0.824. 3. Correlation between $SO_X$ concentration in the air and sulfur contents in the leaves showed positive significance. 4. Contents of soluble sulfur in the heavy traffic area were higher than that of light traffic area. 5. Heavy metal contents of 1986 were higher than that of 1985; Fe> Mn > Zn > Pb > Cu > Cd > Cr. 6. Lead contents in the leaves of 1986 were; Platanus orientalis 16, 701 ppm, Gingobiloba 21,729ppm, Salix Pseudo-lasiogyne 12.418 ppm.

  • PDF

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.

Heavy Metals of the Suspended Particulate in Atmosphere of Seoul City (서울시(市) 대기중(大氣中) 유해(有害) 부유분진(浮遊粉塵)의 성분(成分) -부유분진(浮遊粉塵)의 중금속(重金屬)에 관하여-)

  • Kwon, Sook-Pyo;Chung, Yong;Lim, Dong-Koo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 1979
  • In order to investigate air pollution by heavy metals in Seoul city, the suspended particulates in the atmosphere were sampled with high volume air sampler in industrial area(Ku Ro Dong), commerical(Kwang Hwa Moon) and residential(Shin Chon Dong) from January to November, 1977. The sampled suspended particulates were digested and extracted from suspended particulates with the acidic solution by reflux-extraction technique, and were measured by atomic absorption spectrophotometry. And mercury was measured by mercury analyzer applying the reducing sublimation technique. Among heavy metals analyzed, the iron was identified at the highest level in the suspended particulates and the chromium was the least. Through the surveyed area, the concentration of heavy metals of the industrial area was comparatively high among others and the commercial was the second. It was detected that lead was the most concentrated in the suspended particulate of the commercial area, that might be caused of the traffic emissions. The seasonal variations were analyzed and the correlations among heavy metals and total suspended particulate were also calculated. Especially, the iron was highly correlated with total suspended particulate in all the surveyed areas.

  • PDF

Expansion Properties of Concrete under Various Unit Contents of Expansion Admixture and Curing Conditions (단위 팽창재량 및 양생 환경요인 변화에 따른 콘크리트의 팽창 특성)

  • 한천구;류현기;홍상희;김정진
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.1
    • /
    • pp.79-88
    • /
    • 2000
  • Usually, the expansive additives is used to prevent the occurrence of drying shrinkage in concrete. However it may sometimes be over-added in field due to the insufficient cognition of constructor's, which may cause the serious problems in concrete structures. In this study the experiments are performed to present the expansion properties of concrete by varying the water to binder ratios, unit contents of expansive additives and curing conditions. By the results, the strength showed an increase with the addition of expansion additives from 30kg/㎥ up to 50kg/㎥, and a great decrease by contraries if the larger amount are added. Also the more the expansion additives were used, the more length change occurred in concrete. In view of the curing conditions, the concrete by air cured appeared a little expansion even the unit expansion additives increased, which showed an opposite inclination of that with standard curing. This could be explained by the less occurrence of hydration in air condition which also lead to the little expansion of concrete. Hence the expansion concrete to be cured in water or moisture condition became an especial important thing. concrete using expansive additives showed that high expansion was taken place with the rise of temperature.

Estimation of Multi-Route Exposure and Aggregated Risk Assessment for Cadmium and Lead (카드뮴과 납의 다경로 노출량 추정 및 통합 위해성 평가)

  • Yu, Changwoo;Kwon, Hoonjeong
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.6
    • /
    • pp.587-601
    • /
    • 2020
  • Exposure to hazardous substances occurs through multiple pathways. Aggregated risk assessment, which includes all potential exposure pathways to a single toxicant, is necessary to prevent exposure to harmful substances. We aimed to estimate cadmium and lead exposure through various media, such as food, water, air, smoking, cosmetics, and female hygiene products. This study covered 10,733 subjects from the Seventh Korea National Health and Nutrition Examination Survey(2016, 2017). Dietary exposure was estimated using 24-hour recall data. For water and inhalational exposure, regional variations were considered. Water was classified as tap, bottled, and public water. Inhalational exposure was estimated using the '2014 Time Use Survey' based on daily lifestyle and social status. The frequency and volume of cosmetic usage were randomly approximated by sex and age. Post-menarcheal and premenopausal women were assumed to use feminine hygiene products. Non-carcinogenic aggregated risks were estimated using the Aggregate Risk Index from EPAs and the Total Exposure Hazard Index from Korean government guidelines. For carcinogenic risk assessment, excessive cancer risk was estimated. Ingestion, especially food, was the major route for both cadmium and lead exposure. Smoking was also associated with high cadmium exposure. Exposure to lead from cosmetics was remarkable but not critical. In aggregate risk assessments, median cadmium and lead exposure did not exceed the reference value. Sex, age, smoking status, and income affected exposure levels, unlike to regional variations.

Economic Evaluation of Liquid Air Energy Storage (LAES) System (액화 공기 에너지 저장 기술(LAES)의 경제성 분석)

  • Ko, Areum;Park, Sung-Ho;Ryu, Ju-Yeol;Park, Jong-Po
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Liquid air energy storage (LAES) using gas liquefaction has attracted considerable attention because of its mature technology, high energy density, few geographical constraints, and long life span. On the other hand, LAES has not yet been commercialized and is being developed recently. Therefore, few studies have performed an economic analysis of LAES. In this study, the levelized cost of electricity was calculated and compared with that of other energy storage systems. As a result, the levelized cost of electricity of LAES was $371/MWh. This is approximately $292/MWh, $159/MWh, $118/MWh, and $3/MWh less than that of the LiCd battery, VRFB battery, Lead-acid battery, and NaS battery. In addition, the cost was approximately $62/MWh and $195/MWh more than that of Fe-Cr flow battery and PHS. Sensitivity analysis of the levelized cost of electricity according to the main economic factors was performed, and economic uncertainty analysis was performed through a Monte-Carlo simulation. The cumulative probability curve showed the levelized cost of electricity of LAES, reflecting price fluctuations in the air compressor cost, electricity cost, and standing reserve hourly fee.

Past and Future Temperature and Precipitation Changes over Korea using MM5 Model

  • Oh, Jai-Ho;Min, Young-Mi;Kim, Tae-Kook;Woo, Su-Min;Kwon, Won-Tae;Baek, Hee-Jeong
    • Proceedings of the Korean Quaternary Association Conference
    • /
    • 2004.06a
    • /
    • pp.29-29
    • /
    • 2004
  • Long term observational analysis by climatologists has confirmedthat the global warming is no longer a topic of debate among scientists andpolicy makers. According to the report of IPCC-2001 (Intergovernmental Panelon Climate Change), the global mean surface air temperature is increasinggradually. The reported increase of mean temperature is by 0.6 degree in the end of twentieth century. This could represent severe threat for propertylosses especially due to increase in the number of extreme weather arising out of global warming. period of model integration from 2001 to 2100 using output of ECHAM4/HOPE-G of Max Planet Institute of Meteorology (MPI) for IPCC SRES (Special Report on Emission Scenarios). The main results of this study indicate increase of surface air temperature by 6.20C and precipitation by 2.6% over Korea in the end of 21st century. Simulation results also show that there is increase in daily maximum and minimum temperatures while decrease in diurnal temperature range (DTR). DTR changes are diminished mainly due to relatively rapid increase of daily minimum temperature than that of daily maximumtemperature. It has been observed that increase in precipitation amount anddecrease in the number of rainy days lead to increase of pre precipitationintensity.

  • PDF

An Experimental Investigation of Yarn Tension in Simulated Ring Spinning

  • Tang Zheng-Xue;Wang Xungai;Fraser W. Barrie;Wang Lijing
    • Fibers and Polymers
    • /
    • v.5 no.4
    • /
    • pp.275-279
    • /
    • 2004
  • Yarn tension is a key factor that affects the efficiency of a ring spinning system. In this paper, a specially constructed rig, which can rotate a yam at a high speed without inserting any real twist into the yarn, was used to simulate a ring spinning process. Yarn tension was measured at the guide-eye during the simulated spinning of different yarns at various balloon heights and with varying yarn length in the balloon. The effect of balloon shape, yarn hairiness and thickness, and yam rotating speed, on the measured yarn tension, was examined. The results indicate that the collapse of balloon shape from single loop to double loop, or from double loop to triple etc, lead to sudden reduction in yarn tension. Under otherwise identical conditions, a longer length of yarn in the balloon gives a lower yarn tension at the guide-eye. In addition, thicker yarns and/or more hairy yarns generate a higher tension in the yarn, due to the increased air drag acting on the thicker or more hairy yarns.

A Numerical Analysis on the Characteristics of Spray by Swirl Injector in Gas Turbine Combustor (가스터빈연소기에서 스월 인젝터의 분무특성에 관한 연구)

  • 이성혁;유홍선;이인섭;홍성국
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.30-39
    • /
    • 2000
  • The present paper deals with the numerical simulation for the spray characteristics with swirling turbulent flows and dilution flows from swirl injectors in a simplified can type of gas turbine combustor. The main objective is to investigate the characteristics of swirling turbulent flows with dilution flows and to provide the qualitative results for the spray characteristics such as the droplet distribution and Sauter Mean Diameter(SMD). The gas-phase equations based on Eulerian approach were discretized by Finite Volume Method, together with SIMPLE algorithm and the Reynolds -Stress-Model. The liquid-phase equations based on Lagrangian method were used to predict the droplet behavior. The results of preliminary test are generally in good agreement with experimental data, and show that the anisotropy exists in the primary zone due to swirl velocity and injected air from primary injector, and then gradually decays due to turbulent mixing and consequently near-isotropy occurs in the region between primary and dilution zones. For the spray characteristics, it is indicated that the swirling flows of primary jet region increase the droplet atomization. In addition, it is showed that the swirling flows at the inlet region lead the air-fuel mixture to be distributed near the igniter and can significantly affect the spray behavior in the primary jet region.

  • PDF