• 제목/요약/키워드: Layer Removal

검색결과 668건 처리시간 0.028초

하수관거에 퇴적된 유기물에 의한 악취 발생과 산화전리시스템을 이용한 악취 저감 (Odor Emission from Sediments in Sewer Systems and Odor Removal using an Electrolytic Oxidation Process)

  • 안해영;신승규;송지현
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.703-710
    • /
    • 2011
  • Odor emission from domestic sewer systems has become a serious environmental problem. An investigation on a sewer manhole revealed that anaerobic decay of sediment organic matters (SOMs) and related declines of oxidation reduction potential (ORP) in the sediment layer were the main reason of the production of volatile sulfur compounds. In addition, as the anaerobic decaying period continued, the odor intensity rapidly increased with increasing concentrations of $H_2S$ and dimethyl sulfide. As a feasible method to control SOMs and to minimize odor emission potentials, an electrolytic oxidation process has been employed to the sediment sludge phase. In this study, voltages applied to the electrolytic oxidation process were varied as a main system parameter, and its effects on odor removal efficiencies and reaction characteristics were investigated. At the applied voltages greater than 20 V, the system efficiently oxidized the organic matter, and the ORP in the sludge phase increased rapidly. As a consequence, the removal efficiency of hydrogen sulfide was found to be >99% within 60 minutes of the electrolytic oxidation. Overall, the electrolytic oxidation process can be an alternative to control odor emission from sewer systems, and a threshold input energy needs to be determined to achieve effective operation of the process.

PEI/PEBAX 복합 중공사 막을 이용한 수분 제거에 관한 연구 (Study on the Removal of Water Vapor Using PEI/PEBAX Composite Hollow Fiber Membrane)

  • 박천동;형찬희;김기홍;최원길;박영성;이형근
    • 멤브레인
    • /
    • 제23권2호
    • /
    • pp.119-128
    • /
    • 2013
  • 본 연구에서는 복합 중공사 막을 이용하여 가스 중 수분(water vapor)의 제거에 관한 연구를 수행하였다. 막 소재로는 PEI (Polyetherimide)를 사용하였고 건/습식 상전이 법을 이용하여 중공사 형태로 제조한 후, 표면에 PEBAX (Polyether block amides) 3533또는 PEBAX1657를 코팅하여 복합 중공사막을 제조하였다. 제조된 중공사 막에 대한 SEM 관찰을 통하여 외부 표면에 치밀한 선택층과 망상구조의 하부로 이루어진 비대칭 구조임을 확인하였다. 막의 수분 투과특성을 확인하기 위하여 수분활성도(Water activity), 온도와 압력 변화에 따른 수분과 $N_2$의 투과도를 측정하였다. PEBAX3533을 코팅한 복합중공사 막의 수분 투과도는 운전 조건에 따라 385.6~727.3 GPU, 수분/$N_2$ 선택도는 61.7~118.5의 값을 나타내었다. PEBAX1657 코팅의 경우, 수분 투과도는 204.1~562.1 GPU, 수분/$N_2$ 선택도는 85.3~175.4의 값을 나타내었다. 막의 수분제거율은 PEBAX3533 코팅한 경우에 90%를 나타내었다.

담체가 첨가된 침지형 막결합 연속회분식 반응기에서 제거효율과 여과성능에 대한 담체의 효과 (The Effect of Media on the Removal Efficiency and Filtration Performance in the Submerged Membrane-Coupled Sequencing Batch Reactor with Media)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.450-460
    • /
    • 2012
  • 스펀지 형태의 담체가 첨가된 침지형 막결합 연속회분식 생물반응기에서 담체가 제거효율과 여과성능에 미치는 영향을 조사하였다. 담체는 반응기 부피 기준으로 각각 5%, 10% 및 20% 첨가하였고, 담체를 첨가하지 않은 반응기를 대조군으로 하였다. COD, T-N 및 T-P에 대한 제거효율은 담체 첨가 유무에 관계없이 큰 차이가 없었다. 그러나 담체를 첨가한 경우, 첨가하지 않은 경우에 비해 조업시간에 따른 막간차압(TMP)은 매우 서서히 증가하였다. 이러한 결과는 폭기에 의해 상승하는 담체가 막 표면과 충돌하게 되고, 이때 막 표면에 형성된 케이크 층을 제거시키기 때문이다. 결론적으로 담체가 첨가된 막결합형 연속회분식 생물반응기는 담체가 없는 반응기에 비해 여과성능이 크게 개선되어, 폐수처리에 효과적으로 활용될 수 있을 것이다.

단결정 실리콘 태양전지 도핑 확산 공정에서 주입되는 $O_2$ 가스와 PSG 유무에 따른 특성 변화 (The Study on the Characteristic of Mono Crystalline Silicon Solar Cell with Change of $O_2$ Injection during Drive-in Process and PSG Removal)

  • 최성진;송희은;유권종;이희덕
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.105-110
    • /
    • 2011
  • The doping procedure in crystalline silicon solar cell fabrication usually contains oxygen injection during drive-in process and removal of phosphorous silicate glass(PSG). In this paper, we studied the effect of oxygen injection and PSG on conversion efficiency of solar cell. The mono crystalline silicon wafers with $156{\times}156mm^2$, $200{\mu}m$, $0.5-3.0{\Omega}{\cdot}cm$ and p-type were used. After etching $7{\mu}m$ of the surface to form the pyramidal structure, the P(phosphorous) was injected into silicon wafer using diffusion furnace to make the emitter layer. After then, the silicon nitride was deposited by the PECVD with 80 nm thickness and 2.1 refractive index. The silver and aluminium electrodes for front and back sheet, respectively, were formed by screen-printing method, followed by firing in 400-425-450-550-$880^{\circ}C$ five-zone temperature conditions to make the ohmic contact. Solar cells with four different types were fabricated with/without oxygen injection and PSG removal. Solar cell that injected oxygen during the drive-in process and removed PSG after doping process showed the 17.9 % conversion efficiency which is best in this study. This solar cells showed $35.5mA/cm^2$ of the current density, 632 mV of the open circuit voltage and 79.5 % of the fill factor.

  • PDF

Effects of Polymer Adsorption on Stabilities and CMP Performance of Ceria Abrasive Particles

  • Shimono Norifumi;Kawaguchi Masami;Koyama Naoyuki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.112-117
    • /
    • 2006
  • In this paper we present that the effects of polymer adsorption on stabilities and CMP performance of ceria abrasive particles. Characterization of ceria abrasive particles in the presence of poly(vinyl pyrrolidone) (PVP) was performed by the measurements of adsorbed amounts of PVP, average sizes, and the back scattering intensities of the ceria abrasive particles as functions of PVP molecular weight and PVP concentration. The ceria abrasive particles in the presence of PVP were used to polish $SiO_2\;and\;Si_3N_4$ films deposited on Si wafers in order to understand the effect of PVP adsorption on chemical mechanical polishing (CMP) performance, together with ceria abrasive particles without PVP. Adsorption of PVP on the ceria abrasive particles enhanced the stability of ceria abrasive particles due to steric stabilization of the thick adsorbed layer of PVP. Removal rates of the deposited $SiO_2\;and\;Si_3N_4$ films by the ceria abrasive particles in the presence of PVP were much lower than those in the absence of PVP and their magnitudes were decreased with an increase in the concentration of free PVP chains in the dispersion media. This suggests that the CMP performance in the presence of PVP could be mainly controlled by the hydrodynamic interactions between the adsorbed PVP chains and the free ones. Moreover, the molecular weight dependence of PVP on the removal rates of the deposited films was hardly observed. On the other hand, high removal rate selectivity between the deposited films in the presence of PVP was not observed.

역삼투막의 선택적 제거특성을 이용한 원자력발전소 붕산수 중의 실리카 제거에 관한 연구 (Study on Silica Removal from Borated Water Using Reverse Osmosis Membranes in Nuclear Power Plants)

  • 윤석원;박광규
    • 멤브레인
    • /
    • 제7권4호
    • /
    • pp.167-174
    • /
    • 1997
  • 고온, 고압으로 운전되고 있는 원자력발전소의 1차 계통수측에서, 실리카는 양이온 불순물과 결합하여 핵연료 피복재에 규석(zeolite)층을 형성하므로 계통구조물의 건전성에 영향을 미치게 된다. 따라서 핵연료와 접촉하는 1차 계통수측에서는 규제치 이하의 수준으로 실리카 농도가 유지되어야 한다. 본 논문에서는 실리카 제거 작업시 발생되는 방사성 폐기물의 양을 최소화 하고 붕산 소모량을 줄이기 위해, 상용화 되어 있는 5종류의 막을 이용하여 붕산 및 실리카가 함유된 수용액에 대한 조업온도, 공급유량 변화가 투과량, 붕소회수율, 실리카 배제율에 미치는 영향에 대하여 실험을 수행하였다. 이를 이용하여 계통수내에서 실리카 만을 효과적으로 제거할 수 있는 장치를 설계하였으며, 특성이 다른 2종류의 막을 3단으로 구성하여 상황변화에 따른 대응능력을 높였다. 실험결과 기존 원자력발전소에서 사용하고 있는 Feed and Bleed 방법에 비해 폐기물 발생량은 7%에 불과했고, 농축 폐기물에 포함되어 소모된 붕산의 양은 15.7%에 불과하였다.

  • PDF

Experimental Study on Poultices Applying to Remove Fixative (Paraloid B72) on Earthen Mural Painting

  • Lee, Kyeong Min;Moon, Hye Young;Yu, Yeong Gyeong;Kim, Soon Kwan
    • 보존과학회지
    • /
    • 제34권6호
    • /
    • pp.569-580
    • /
    • 2018
  • The possibility of applying poulticing was studied for removing Paraloid B72, a resin used for fixing an earthen mural painting. Five types of poultices were selected from clay and gel types, and acetone, ethanol, and methyl ethyl ketone(MEK) were used as mixed solvents. The possibility of mixing between the poultice and solvent was investigated, and then the spreadability, fluidity, acidity, drying properties, and solubility of the poultices were examined to confirm the characteristics. A poultice agent, which is suitable for applying to a mural painting, was selected and applied to a painting layer sample coated with Paraloid B72. As a result, all painting layers were good condition at under 50% of the solvent. The removal efficiency of Paraloid B72 was more effective when most of the solvents were used at 50%, rather than at 25%. However, it is difficult to mix 50% of MEK and ethanol with the gel-type poultices. When used at 25%, the removal performance was poorer than that at 50%, but the mixing with all the poultices was successful. In addition, the adsorption and removal power of the gel-type poultice were better than those of the clay-type, but the latter was expected to be more suitable in short-time cases due to its high drying speed. The results of this study show that the dissolution performance varies depending on the poultices and solvents. Hence, the poultice and solvent should be selectively applied, considering the fixative of the mural to be removed.

석탄 저회-규사 필터의 입자상물질 여과 성능 실험적 평가 (Experimental Evaluation of Particulate-matter Filtration Performance of a Bottom Ash-Silica Sand Mixture)

  • 이동현;이홍경;이윤제;안재훈
    • 한국지반공학회논문집
    • /
    • 제38권6호
    • /
    • pp.41-47
    • /
    • 2022
  • 투수성 포장은 강우를 노반으로 침투시켜 지표면 유출량 감소와 수질 개선을 기대하기 위한 기술이다. 수질 개선효과의 증대를 위해 투수성 포장 내에는 필터층을 추가하기도 한다. 본 연구에서는 투수성 포장의 구성 요소인 여재 필터의 성능을 알아보기 위해 석탄 저회-규사 여재에 대한 투수성능과 입자상 물질 제거 효율을 분석하였으며, 석탄저회와 규사를 기본 재료로 하는 5개의 여재를 대상으로 하였고, 입자상 물질로는 60㎛ 이하의 입자를 사용하였다. 순수 규사 시료 혹은 순수 석탄저회 시료는 평균적으로 약 70%의 입자상 물질 제거효율을 보였으나, 혼합 시료의 경우 제거 효율이 약 90%로서, 비점오염 저감시설에 대한 저감율 권고치인 80%를 상회하는 것으로 나타났다. 향후 현장 검증을 통한 투수성 포장 내 여재 필터 성능에 대한 검증 후 도로 시설 혹은 독립적인 여과 장치로 사용할 수 있을 것으로 판단한다.

A Comparative Study Between High and Low Infiltration Soils as Filter Media in Low Impact Development Structures

  • Guerra, Heidi B.;Geronimo, Franz Kevin;Reyes, Nash Jett;Jeon, Minsu;Choi, Hyeseon;Kim, Youngchul;Kim, Lee-Hyung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.130-130
    • /
    • 2021
  • The increasing effect of urbanization has been more apparent through flooding and downstream water quality especially from heavy rainfalls. In response, stormwater runoff management solutions have focused on runoff volume reduction and treatment through infiltration. However, there are areas with low infiltration soils or are experiencing more dry days and even drought. In this study, a lab-scale infiltration system was used to compare the applicability of two types of soil as base layer in gravel-filled infiltration systems with emphasis on runoff capture and suspended solids removal. The two types of soils used were sandy soil representing a high infiltration system and clayey soil representing a low infiltration system. Findings showed that infiltration rates increased with the water depth above the gravel-soil interface indicating that the available depth for water storage affects this parameter. Runoff capture in the high infiltration system is more affected by rainfall depth and inflow rates as compared to that in the low infiltration system. Based on runoff capture and pollutant removal analysis, a media depth of at least 0.4 m for high infiltration systems and 1 m for low infiltration systems is required to capture and treat a 10-mm rainfall in Korea. A maximum infiltration rate of 200 mm/h was also found to be ideal to provide enough retention time for pollutant removal. Moreover, it was revealed that low infiltration systems are more susceptible to horizontal flows and that the length of the structure may be more critical that the depth in this condition.

  • PDF

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성 (Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant)

  • 장갑성;김흥중;박주철;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF