• Title/Summary/Keyword: Law on Indoor Air Quality Management

Search Result 7, Processing Time 0.029 seconds

An Exploratory Research on Social Workers' Attitude and Related Factors about Indoor Air Quality Management of Social Welfare Facilities (사회복지시설 종사자의 실내공기질 관리에 대한 태도와 관련 요인에 관한 탐색적 연구)

  • Bae, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.5
    • /
    • pp.273-284
    • /
    • 2017
  • As these days people spend most of time at inner space, indoor air quality affect human life seriously. Government manage indoor air quality of various facilities based on different laws. Government released that they would try to protect environment for vulnerable people such children and seniors from indoor air pollutants in 2015. But social welfare facilities are exception under current legal systems. Clients of social welfare residential facilities are the disables, the elderly, homeless and children and they usually stay inner space very long time. The purpose of this study is explore workers' attitude and related factors about indoor air quality management of social welfare facilities. 69.5% of respondents agree to government's indoor air quality management, 80.9% of respondents think social welfare facilities must be included in legal system for indoor air quality management. Environmental awareness and law awareness were related with attitude to indoor air quality management. Based on the results of the analysis, I propose the amendment of law on indoor air quality of the Ministry of Environment, cost burden of central or local government and the necessity of education and research on indoor air quality management in social welfare facilities.

Management Policy and Control Technology for Indoor Air Quality in Korea (국내 실내공기질 관리정책의 변천 및 제어기술의 현황)

  • Bae, Gwi-Nam;Ji, Jun-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.378-389
    • /
    • 2013
  • In Korea, studies on the indoor air quality have been conducted since mid of 1980s. The turning point occurred in 2003 by establishing the act of the indoor air quality management for public facilities. According to the law, the basic plan for indoor air quality management is prepared by government every five years, affecting greatly governmental policy and related academia and industries. Indoor air quality survey was mostly carried out among indoor air quality researches. After then, assessment of health effect and air cleaning technology were studied. Although various control technologies for particle, bioaerosol, odor, and hazardous chemicals have been applied to indoor environments, breakthrough technologies are needed to solve real problems facing at the applied environments. In the future, issue of indoor air quality is more interested and both management policy and control technology are key factors in order to realize comfort and healthy indoor environments.

A Study on the Brand Service Design for Measuring and Managing Indoor Air Quality (실내공기질 측정 및 관리를 위한 브랜드 서비스디자인 연구)

  • Kim, Seung-Beom;Kim, Hwoi-Kwang
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.325-333
    • /
    • 2018
  • The quality of indoor air quality is facing a very serious situation due to the impact of the quality of the atmosphere in the atmosphere and the surrounding environment. While awareness of the danger of these populations is increasing, there is no way to detect the quality of the indoor air quality as well as the measures to detect the quality of indoor air quality as well as the countermeasures. The study drew a general problem with the design of the service design, the general purpose of the general office, and the use of the public facilities for the purpose of measuring the usage of indoor air quality, the general purpose of public facilities, and the interpretation of the current law. Based on this research, most of the general users' perception of the seriousness of the disease is not reflected in the perception that the dust and indoor air are accumulated in the eyes of the general public.

Study on Indoor Air Pollutants of Public Service Centers in Winter, Seoul (서울지역 공공청사 민원실의 겨울철 실내공기질에 관한 연구)

  • Jeon, Jea-Sik;Kim, Mi-Hyung;Lee, Ju-Yeol;Jeon, Myung-Jin;Ryu, In-Cheol;Park, Duck-Shin;Choi, Han-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.569-579
    • /
    • 2011
  • This study evaluated the indoor air quality of 26 government offices located in Seoul. The pollutant samples were taken from Jan. 13th to Jan. 29th and Feb. 20th to Feb. 23rd, 2010 in the offices. The target indoor pollutants for this study were $PM_{10}$, formaldehyde, carbon monoxide, carbon dioxide, total bacteria counts, total volatile organic compounds, radon, nitrogen dioxide, ozone, and asbestos which were controlled by the indoor air quality law for the multiple-use facilities management. The results of this study showed that some pollutants of the 38.5% offices exceeded the standards of the air quality guideline. The correlation analysis of the same pollutants between indoor and outdoor represented that $NO_2$ (r=0.629, p<0.05) and $O_3$ (r=0.459, p<0.01) were significant, however, $PM_{10}$ and CO were not. The correlation analysis between different pollutants showed that CO and TVOC (total volatile organic compounds: r=0.724; p<0.01), CO and $NO_2$ (r=0.674; p<0.01), HCHO and humidity (r=0.605; p<0.01), $CO_2$ and TVOC (r=0.534; p<0.01), TBC (total bacteria counts) and Asbestos (r=0.520; p<0.01) were significant. The energy-saving system of government buildings in winter caused under-ventilated and poor air quality. This study suggests that the concentrations of radon and $CO_2$ should be used as an indicator for monitoring indoor air quality and maintaining effective ventilations.

Indoor Air Quality in Various Type of Public Facilities at Honam Province (호남지역의 다중이용시설별 실내공기질 실태 조사)

  • Seo, Byeong-Ryang;Jeong, Man-Ho;Jeon, Jun-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

The TVOC management level evaluation of adhesive product following to simultaneous revision of indoor air quality testing methods and standards (실내공기질 공정시험방법과 기준의 동시 개정에 따른 접착제 제품의 TVOC 관리수준 평가)

  • Yoo, Ji-Ho;Park, Joon-Man;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.255-260
    • /
    • 2010
  • The Ministry of Environment simultaneously revised testing methods and emission standards of adhesives product on the "Law of indoor air quality management" for the effective management of the building materials releasing pollutants in great quantities. Accordingly, it is impossible to compare original standards with revised standards directly. The influences of each factor of the revised testing methods of adhesive product on the emission rate of pollutants are reviewed through comparing with the original testing method. Through this study, revised pollutant emission control standards were assessed. With the result that it is found that emission rate of adhesives product is weakened two and half times by changing test period and the emission rate resulting from changing drying time has little difference. As a result of comparing TVOC emission standards with the original testing method considering the modification of testing methods, it is found that the emission standard through this revision is strengthened about 2.1 times more than that of present testing method.

Evaluation of TVOC regulation level of sealant products in accordance with simultaneous revision of testing method and regulation value in the law of indoor air quality management (실내 공기질 공정시험방법과 기준의 동시 개정에 따른 실란트 제품의 TVOC 관리수준 평가)

  • Yoo, Ji-Ho;Park, Joon-Man;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.138-146
    • /
    • 2010
  • The Korean Ministry of the Environment revised a few sections of the regulations in the Law of indoor air quality management for the reinforcement or adjustment of the regulation criteria standard for releasing pollutants from building materials. Especially, in case of sealant, the contents covering liquid building materials, excess standards and testing methods have been added simultaneously in this revision, As a result it is impossible to compare original standards with revised standards directly. For this reason, this study reviewed revised test method of sealant pollutant emission rates in terms of impact and validity in comparison with the original test method. Through this study, the basic properties of revised pollutant emission control standards was assessed. Especially in sealant, since each product has a wide deviation of time required for complete drying, it is proved that there are a large number of products that are not hardened completely in test time. The result of our experiments on the revised test methods showed that this revised test methods yield emission rates that are two and half times less than those of the original testing method. To apply the revised test method of sealant to all the sealant products, It is necessary to extend the test period or improve specimen to fit the test method for quickly drying sealant products.