• Title/Summary/Keyword: Lateral neck point

Search Result 26, Processing Time 0.031 seconds

The Treatment of a Droopy Shoulder Syndrome Patient -A case report- (Droopy Shoulder Syndrome 환자의 치료경험 -증례보고-)

  • Park, Eun Young;Shim, Jae Kwang;Rhee, Ho Dong;Kim, Won Oak;Yoon, Kyung Bong;Yoon, Duck Mi
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.296-298
    • /
    • 2006
  • Droopy shoulder syndrome (DSS) is a rare disease, characterized by drooping shoulders, which stretches the brachial plexus, and causes pain, but without any signs of neurological impairment. These patients suffer from pain in the neck, shoulders, arms and hands, which result in long, graceful, swan necks, low-set shoulders, and horizontal or down sloping clavicles. No abnormalities in the vascular, neurological or electrical findings have also been known. The T1 and/or T2 bodies can be seen in the lateral view in a radiological study of the cervical spine. In the majority of cases, conservative treatments, such as postural correction and shoulder girdle strengthening exercise, are commonly recommended. However, DSS may be misdiagnosed as severe thoracic outlet syndrome or herniated cervical disc disease, leading to unnecessary and hazardous invasive treatments. The presented case was consistent with DSS, and was treated with stellate ganglion block, trigger point injection, and shoulder girdle strengthening exercise.

The clinical observation of patient with Headache Treated by Trigger point acupuncture therapy (발통점(發通點)을 이용(利用)한 두통(頭痛) 치험례(治驗例) 보고(報告))

  • Lee Seung-Yeon;Kim Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.133-143
    • /
    • 1998
  • Myofascial pain syndrome is one of the pain syndrome resulted from myofascia which covered muscles and clinically characteristic feature by sensitive trigger point in skeletal muscles and referred pain reactivated by stimulating each trigger point. The origin of headache are local lesion such as head, chest, abdominal organ, systemic lesion with fever or in toxic state. the other factors are consciousness, personality, anxiety, depression, which cause muscle strain in physiological environment. The Oriental Medical therapy for headache has herb medication and acupuncture. especially acupuncture therapy has not only classical systemic acupuncture(體鍼) but also neo-acupuncture(新鍼) such as commonly using auricular acupuncture(耳鍼) and manual acupuncture (手鍼), recently trigger point acupuncture is used. The author analyzed 27 cases of patient with headache treated by trigger point acupuncture therapy in Dong-yu Oriental Medical Hospital from March 1st 1997 to February 28th 1998. The following results were obtained. 1. The sex ratio of the female was 59.26%(16 cases) and male was 40.74%(11 cases), the ratio of high school student was 62.96%(17cases) as first. 2. The headache duration ratio of 2-3 years was 37.04%(10 cases) as first, 1-2 years was 25.93%(7 cases) as second. 3. The portion ratio of whole headache was 33.33%(9 cases) as first, lateral headache was 29.63%(8 cases) as second 4. The combined symptoms ratio of anorexia was 40.74%(11 cases) as first, fatigue was 33.33%(9 cases) as second, neck stiffness and dizziness was each 25.93%(7 cases) as third. 5. The therapeutic duration ratio of below 1 week was 29.63%(8 cases) as first, 2-3 weeks was 22.22%(6 cases) as second, 1-2 weeks and 3-4 weeks was each 18.52%(5 cases) as third. 6. The ratio of family history was 11 cases(40.74%). mother with headache was 6 cases, father was 3 cases, and brothers & sisters was 2 cases. 7. The herb medication ratio of Chungsanggyuntongtang(淸上?痛湯) was 37.04%(10 cases), Kamiondamtang(加味溫膽湯) was 22.22%(6 cases), Hyangsapyunguisan(香砂平胃散) was 18.25%(5 cases) etc. 8. The remedial effect ratio of good was 25.93%(7 cases), fair was 48.15%(13 cases), not improved was 7.41%(2 cases), side effect was 3.70%(1 cases), and unknown was 14.81%(4 cases).

  • PDF

Dose distribution at junctional area for head and neck radiotherapy (두경부 방사선치료시 접합 조사면의 선량분포)

  • 김정기;김기환;오영기;김진기;정동혁;신교철;양광모;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2001
  • For the head and neck radiotherapy, the technique of half beam using independent collimator is very useful to avoid overlapping of fields particularly when the lateral neck fields are placed adjacent to anterior supraclavicular field. Also abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom and the dose distribution at beam center of 2 half beams further examined according to depths(0 cm, 1.5 cm, 3 cm, 5 cm) for single anterior half beam and anterior/posterior half beam. The dose distribution to the junction line between photon and electron fields was also measured. For the single anterior half beam, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 88%, 93% and 95% of open beam, respectively. In the anterior/posterior half beams, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 92%, 93% and 95% of open beam, respectively At the junction line between photon and electron fields, hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. With above results, we concluded that when using electron beam or independent jaw for head and neck radiotherapy, the hot and cold dose area should be considered as critical point.

  • PDF

A study on the Cochlear View in Multichannel Cochlear Implantees (인공와우 이식술 환자의 Cochlear View 촬영에 관한 연구)

  • Kweon, Dae-Cheol;Kim, Jeong-Hee;Kim, Seong-Lyong;Kim, Hae-Seong;Lee, Yong-Woo
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.27-32
    • /
    • 1999
  • Cochlear implant poses a contraindication to the magnetic resonance imaging(MRI) process, because MRI generates artifacts, inducing an electrical current and causing device magnetization. CT is relatively expensive and the metal electrodes scatter the image. Post-implantation radiological studies using anterior-posterior transorbital, submental-vertex and lateral views, the intracochlear electrodes are not well displayed. Therefore, the authors developed a special view, which we call the cochlear view. The patient is sitting in front of a vertical device. Then the midsagittal plane is adjusted to form an angle of $15^{\circ},\;30^{\circ}$, and $45^{\circ}$ with the film. The flexion of the neck is adjusted to make the infraorbitomeatal line(IOML) is parallel with the transverse axis of the film. The central ray is directed to exit from the skull at point which is 3.0 cm anterior and 2.0 cm superior to the EAM(external auditory meatus). Results have shown that single radiography of the cochlear view provides sufficient information to demonstrate the position of the electrodes array and the depth of insertion in cochlear. Radiography of the cochlear view in angle of $45^{\circ}$ is an excellent image. The cochlear view gives the greatest amount of medical information with the least radiation and lowest medical cost. It can be widely used in all cochlear implant clinics.

  • PDF

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF