• Title/Summary/Keyword: Lateral drift

Search Result 280, Processing Time 0.036 seconds

The Effects of Coupling Beam on Lateral Drift of High-rise Buildings (고층건물의 횡변위에 대한 커플링보의 효과)

  • Kim, Jin-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5931-5937
    • /
    • 2011
  • The effects of coupling beam, which is generally used in high-rise building structure system as shear wall-coupling beam, on the lateral drift of high-rise buildings are studied in this paper. Six different analytical models, which are combination of two inputs, such as concrete strength and wall thickness, are selected and analyzed on lateral drifts with different stiffness of coupling beams. MIDAS GEN was used for analysis. Calculated lateral drifts were compared with allowable limits(H/400~H/500) proposed by standard CEN EC 3/1, in order to analyze the control evaluation of coupling beams. Calculated x-direction displacements were 68~87 percent of allowable limit(H/500). With increase of wall thickness(100mm) and concrete strength(5Mpa), eight to ten percent and four percent of x and y-direction displacement were decreased individually. About three percent of lateral displacement was increased with 20 percent decrease of coupling beam stiffness and additional 20 percent decrease resulted in additional five to eight percent increase.

A lateral load pattern based on energy evaluation for eccentrically braced frames

  • Fakhraddini, Ali;Fadaee, Mohammad Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.27 no.5
    • /
    • pp.623-632
    • /
    • 2018
  • Performance-Based Plastic Design (PBPD) method has been recently developed to evaluate the behavior of structures in different performance levels. The PBPD method utilizes a base shear force and a lateral load pattern that are estimated based on energy and yielding mechanism concepts. Using of current lateral force pattern results in weak structural members in upper stories of a structure so that the values of the story drift in these stories are larger than the target drift, particularly in high-rise buildings. Therefore, such distribution requires modifications to overcome this drawback. This paper proposes a modified lateral load pattern for steel Eccentrically Braced Frames (EBFs) based on parametric study. In order to achieve the modified load pattern, a group of 26 EBFs has been analyzed under a set of 20 earthquake ground motions. Additionally, results of nonlinear dynamic analyses of EBFs have been post-processed by nonlinear regression analysis in order to derive the new load pattern. To prove the efficiency of present study, three EBFs as examples were designed by modified pattern and current PBPD distribution. Inelastic dynamic analyses results showed that the story drifts using modified lateral load pattern were well within the target values in comparison with current pattern in PBPD, particularly where the effect of the height is significant. The modified load pattern reduces the possibility of underdesigning in upper levels and overdesigning in lower levels of the frames.

Mitigation of seismic drift response of braced frames using short yielding-core BRBs

  • Pandikkadavath, Muhamed Safeer;Sahoo, Dipti Ranjan
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.285-302
    • /
    • 2017
  • Buckling-restrained braced frames (BRBFs) are commonly used as the lateral force-resisting systems in building structures in the seismic regions. The nearly-symmetric hysteretic response and the delayed brace core fracture of buckling-restrained braces (BRBs) under the axial cyclic loading provide the adequate lateral force and deformation capacity to BRBFs under the earthquake excitation. However, the smaller axial stiffness of BRBs result in the undesirable higher residual drift response of BRBFs in the post-earthquake scenario. Two alternative approaches are investigated in this study to improve the elastic axial stiffness of BRBs, namely, (i) by shortening the yielding cores of BRBs; and (ii) by reducing the BRB assemblies and adding the elastic brace segments in series. In order to obtain the limiting yielding core lengths of BRBs, a modified approach based on Coffin-Manson relationship and the higher mode compression buckling criteria has been proposed in this study. Both non-linear static and dynamic analyses are carried out to analytically evaluate the seismic response of BRBFs fitted with short-core BRBs of two medium-rise building frames. Analysis results showed that the proposed brace systems are effective in reducing the inter-story and residual drift response of braced frames without any significant change in the story shear and the displacement ductility demands.

Automation model for drift design of high-rise buildings (고층건물 변위설계 자동화 모델)

  • 서지현;박효선
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.143-149
    • /
    • 2004
  • In this paper, an automation model for drift design of high-rise buildings using resizing algorithms is proposed. Drift, in the model, includes the maximum lateral displacement at the top and inter-story drifts of a high-rise building subjected to both wind and seismic load. Resizing algorithms for high-rise buildings in various systems and material developed in previous researches are used as a drift control module. As an input to drift control algorithms, member forces for calculation of member displacement participation factors are obtained from commonly-used commercial softwares. The automation model is composed of 4 modules: initial modeling, drift control, stress check, and final verification modules. Each module in the model is described in detail in this paper.

  • PDF

Optimal Displacement Control of Shear Wall Structure using Sensitivity Analysis Technique (감도해석기법을 이용한 전단벽 구조물의 최적변위제어)

  • Lee Han-Joo;Jung Sung-Jin;Kim Ho-Soo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.121-128
    • /
    • 2005
  • This study presents an effective stiffness-based optimal technique to control quantitatively lateral drift for shear wall structures subject to lateral loads. To this end the displacement sensitivity depending on behavior characteristics of shear wall structures is established. Also, the approximation concept that can preserve the generality of the mathematical programming and can efficiently solve large scale problems is introduced. Resizing sections in the stiffness-based optimal design are assumed to be uniformly varying in size and the technique of member grouping is considered for the improvement of construction efficiency Two types of 11-story shear wall structures are presented to illustrate the features of the quantitative lateral drift control technique proposed in this study.

  • PDF

The Shear Lag Phenomenon in Bundled Tube Structure According to the Arrangement of Structural Members (부재배치에 따른 묶음튜브 구조의 전단지연현상)

  • Kim, Young-Chan;Kim, Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.81-86
    • /
    • 2006
  • The purpose of this study is to examine the effect of column spacing and beam size on the lateral displacement and shear lag phenomenon in bundled tube system. According to the parametric study in which the spacing of columns, the size of columns and girders in bundled tube were selected as a parameter, it is the most efficient to increase the size of the interior columns with the largest reduction of lateral drift if the steel tonnage of a frame can be increased. It was noticed that the shear lag was affected more by the exterior stiffness factor and ratio than by the interior ones when column spacing was changed, and when the size of column was changed, the reverse phenomenon was happened. And The change of column spacing affected shear lag, lateral drift, and tonnage more than that of column size or girder size.

Structural Behavior of Post-Tensioned Flat Plate Slab-Column Connections (포스트 텐션 플랫 플레이트 슬래브 접합부의 거동)

  • Cho Kyung Hyun;Han Sang Whan;Lee Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.53-56
    • /
    • 2004
  • Recently, post tension flat plate slab system is widely used for a new slab structural system. Slab-column connections may fail in brittle manner by punching shear. Flat plate slabs have been widely used for gravity load resisting system in buildings. Lateral resistance usually provided by shear walls or moment resisting frames. Since plat plates move together with lateral loading system during earthquake or wind, it is important to evaluate the gravity resistance under a drift experienced by lateral force resisting system during either design earthquake or wind. Thus, this study investigated post tension flat plate slab systems whether they have sufficient strength and deformability to resist gravity loads during specified drift levels. Experimental research was carried out.

  • PDF

Seismic Performance of Low-rise Piloti RC Buildings with Concentric Core (중심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능)

  • Yoon, Tae-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.611-619
    • /
    • 2022
  • In this study, the seismic performance of low - rise piloti buildings with concentric core (shear wall) position is analysed and reviewed based on KDS 41. The prototype is selected among the constructed low - rise piloti buildings with concentric core designed based on KBC 2005 which was used for many low - rise piloti buildings construction. The seismic performance of the building shows plastic behavior in X-direction and elastic behavior in Y-direction. The inter-story drift is lager than that of concentric core case and is under the maximum allowed drift ratio. The displacement ratio of first story is much lager the that of upper stories, and the frame structure in the first story is evaluated as vulnerable to lateral force. Therefore, low - rise piloti buildings with concentric core need the diminishment of lateral displacement and reinforcement of lateral resistance capacity in seismic design and seismic retrofit.

Analysis on the dynamic characteristics of RAC frame structures

  • Wang, Changqing;Xiao, Jianzhuang
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.461-472
    • /
    • 2017
  • The dynamic tests of recycled aggregate concrete (RAC) are carried out, the rate-dependent mechanical models of RAC are proposed. The dynamic mechanical behaviors of RAC frame structure are investigated by adopting the numerical simulation method of the finite element. It is indicated that the lateral stiffness and the hysteresis loops of RAC frame structure obtained from the numerical simulation agree well with the test results, more so for the numerical simulation which is considered the strain rate effect than for the numerical simulation with strain rate excluded. The natural vibration frequency and the lateral stiffness increase with the increase of the strain rate. The dynamic model of the lateral stiffness is proposed, which is reasonably applied to describe the effect of the strain rate on the lateral stiffness of RAC frame structure. The effect of the strain rate on the structural deformation and capacity of RAC is analyzed. The analyses show that the inter-story drift decreases with the increase of the strain rate. However, with the increasing strain rate, the structural capacity increases. The dynamic models of the base shear coefficient and the overturning moment of RAC frame structure are developed. The dynamic models are important and can be used to evaluate the strength deterioration of RAC structure under dynamic loading.

The Effect of Preventing Lateral Deformation of the Clamp Type Steel Damper in Rocking Behavior (록킹 거동을 하는 꺽쇠형 강재 댐퍼의 횡변형 방지 효과)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.141-148
    • /
    • 2021
  • In this study, the technology to prevent lateral deformation of steel dampers was reviewed and applied to the clamp type dampers. As for the experimental method, the rocking behavior was applied as in the previous study. The evaluation variables are the existing research results (SV-260) without lateral deformation prevention details and the test results (V-1, V-1R) with lateral deformation prevention details. Where, V-1 is the lateral deformation prevention detail at the lower part of the damper, and V-1R is the lateral deformation prevention detail at the lower part and upper part of the damper. As a result of evaluating the moment, drift ratio, and energy dissipation capacity relative to SV-260 at the time of maximum load, the maximum moments of V-1 and V-1R were increased by 1.22 times and 1.36 times compared to SV-260, and the maximum drift ratio increased by 2.41 times and 2.92 times. In addition, the energy dissipation capacity also increased by 1.39 times and 1.52 times, respectively. Therefore, the application of lateral deformation prevention details to the steel damper was evaluated as appropriate.