• 제목/요약/키워드: Lateral cracks

검색결과 89건 처리시간 0.022초

${Al_2}}O_3}-TiO_2$ 플라즈마 코팅된 유리의 입자충격에 의한 손상기구 (Damage mechanism of particle impact in a ${Al_2}}O_3}-TiO_2$plasma coated soda-lime glass)

  • 서창민;이문환;홍대영
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.529-539
    • /
    • 1998
  • A quantitative study of impact damage of ${Al_2}}O_3}-TiO_2$ plasma coated soda-lime glasses was carried out and compared with that of the uncoated smooth glass specimen. The shape of cracks by the impact of steel ball was observed by stereo-microscope and the decrease of the bending strength due to the impact of steel ball was measured through the 4-point bending test. At the low velocity, cone cracks were occurred. As the impact velocity increases, initial lateral cracks were propagated on the slanting surface of a cone crack, and radial cracks were generated at the crushed site. When the impact velocity of steel ball exceeds the critical velocity, the contact site of specimen was crushed due to plastic deformation and then radial and lateral cracks were largely grown. Crack length of coated specimens was smaller than that of uncoated smooth specimen due to the effect of coating layer on the substrate surface. According to impact velocity, the bending strength of coated specimens had no significant difference, compared with that of the uncoated smooth specimen. But this represents that the bending strength of coated specimens was increased, considering the effect of sand blasting damage which was performed to increase the adhesion force of coating layer.

Bending characteristics of Prestressed High Strength Concrete (PHC) spun pile measured using distributed optical fibre strain sensor

  • Mohamad, Hisham;Tee, Bun Pin;Chong, Mun Fai;Lee, Siew Cheng;Chaiyasarn, Krisada
    • Smart Structures and Systems
    • /
    • 제29권2호
    • /
    • pp.267-278
    • /
    • 2022
  • Pre-stressed concrete circular spun piles are widely used in various infrastructure projects around the world and offer an economical deep foundation system with consistent and superior quality compared to cast in-situ and other concrete piles. Conventional methods for measuring the lateral response of piles have been limited to conventional instrumentation, such as electrical based gauges and pressure transducers. The problem with existing technology is that the sensors are not able to assist in recording the lateral stiffness changes of the pile which varies along the length depending on the distribution of the flexural moments and appearance of tensile cracks. This paper describes a full-scale bending test of a 1-m diameter spun pile of 30 m long and instrumented using advanced fibre optic distributed sensor, known as Brillouin Optical Time Domain Analysis (BOTDA). Optical fibre sensors were embedded inside the concrete during the manufacturing stage and attached on the concrete surface in order to measure the pile's full-length flexural behaviour under the prescribed serviceability and ultimate limit state. The relationship between moments-deflections and bending moments-curvatures are examined with respect to the lateral forces. Tensile cracks were measured and compared with the peak strains observed from BOTDA data which corroborated very well. By analysing the moment-curvature response of the pile, the structure can be represented by two bending stiffness parameters, namely the pre-yield (EI) and post-yield (EIcr), where the cracks reduce the stiffness property by 89%. The pile deflection profile can be attained from optical fibre data through closed-form solutions, which generally matched with the displacements recorded by Linear Voltage Displacement Transducers (LVDTs).

구조물 손상 탐지를 위한 경 방향 모드 압전 오실레이터 센서 개발 (Development of a Lateral Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure)

  • 노용래;김동영
    • 한국지진공학회논문집
    • /
    • 제10권6호
    • /
    • pp.125-132
    • /
    • 2006
  • 본 논문에서는 사회기반시설의 손상탐지를 위한 경 방향모드 압전 오실레이터의 가능성을 연구하였다. 경 방향 모드 오실레이터 센서는 구조물의 주요부에 부착된 경 방향 모드 압전소자와 피드백 오실레이터 회로로 구성되어있다. 구조물의 손상은 구조물의 임피던스를 변화를 야기 시키며, 그 결과로 구조물의 공진 주파수가 변화하게 된다. 오실레이터 센서는 간단한 방법으로 이 공진 주파수 변화를 연속적으로 관측할 수 있다. 본 연구에서는 알루미늄 시편에 크랙의 크기와 개수를 인위적으로 변화 시키면서, FEM해석과 실험을 통해 경 방향 모드 압전 오실레이터 센서의 적용 가능성을 증명 하였다.

Seismic analysis of RC tubular columns in air-cooled supporting structure of TPP

  • Wang, Bo;Yang, Ke;Dai, Huijuan;Bai, Guoliang;Qin, Chaogang
    • Earthquakes and Structures
    • /
    • 제18권5호
    • /
    • pp.581-598
    • /
    • 2020
  • This paper aims to investigate the seismic behavior and influence parameters of the large-scaled thin-walled reinforced concrete (RC) tubular columns in air-cooled supporting structures of thermal power plants (TPPs). Cyclic loading tests and finite element analysis were performed on 1/8-scaled specimens considering the influence of wall diameter ratio, axial compression ratio, longitudinal reinforcement ratio, stirrup reinforcement ratio and adding steel diagonal braces (SDBs). The research results showed that the cracks mainly occurred on the lower half part of RC tubular columns during the cyclic loading test; the specimen with the minimum wall diameter ratio presented the earlier cracking and had the most cracks; the failure mode of RC tubular columns was large bias compression failure; increasing the axial compression ratio could increase the lateral bearing capacity and energy dissipation capacity, but also weaken the ductility and aggravate the lateral stiffness deterioration; increasing the longitudinal reinforcement ratio could efficiently enhance the seismic behavior; increasing the stirrup reinforcement ratio was favorable to the ductility; RC tubular columns with SDBs had a much higher bearing capacity and lateral stiffness than those without SDBs, and with the decrease of the angle between columns and SDBs, both bearing capacity and lateral stiffness increased significantly.

입자충격에 의한 유리의 손상기구에 관한 실험적 연구 (An Experimental Study on Damage Mechanism of Glass Resulting Frojm Particle Impact)

  • 서창민;신형섭;황병원
    • 대한기계학회논문집A
    • /
    • 제20권6호
    • /
    • pp.1903-1912
    • /
    • 1996
  • A quantitative study of impact damage of a soda-lime glass was carried out. An initiation and a propagation of cracks by the impact of two inds of steel ball was investigated. The fron, side and rear view of cracks were observed by a stereo-microscope. And the lowering of the benidng strength due to the impact of steel balls was examined through the 4-point bending test. A transparent glass is very helpful to understand and analyze the impact damage behavior of another brittle matereial. A deagdram about crack patterns according to the threshold impact velocity was sketched. A ring crack and a cone crack were formed at the low impact velocity. And as the impact velocity was higher, initial lateral crack was generated on the slanting surface of cone crack, and radial cracks were generated from the outermost ring crack. When the impact velocity of steel balls exceed a critical velocity, the contact site of specimens were crushed. According to the propagation of a cone crack, a rapid strength degradation occurred. In the specimen having crushed region, a bending strength was converged to a constant value instead of strength degradation.

열균열이 화강암의 변형거동에 미치는 영향 (Effects of the Thermal Cracking on the Deformation Behaviour of Granites)

    • 터널과지하공간
    • /
    • 제8권3호
    • /
    • pp.249-256
    • /
    • 1998
  • 결정입자 크기와 광물구성 분포가 른 포천화강암, 거창화강암, 상주화강암을 실험 대상으로 선택하여 $600^{\circ}C$까지 예열처리하였다. 예열에 따른 열균열의 발생 정도를 조사하기 위하여 연마편에 대한 반사현미경 관찰을 실시하였으며, 예열시험편의 변형거동에 열균열이 미치는 영향을 평가하기 위하여 단축압축시험을 수행하였다. 현미경 관찰 결과에 의하면 암종에 관계없이 $600^{\circ}C$예열시험편의 결정 경계부에서는 대부분 경계균열이 발생하였으며, 많은 결정입자에서 입자 내 균열고 관찰되었다. 특히, 입자 내 균열은 거창화강암과 포천화강암에서 현저히 많은 것으로 나타났다. 예열시험편에 대한 단축압축시험 결과 일정한 응력수준까지 음의 횡변형율이 발생하는 비정상적인 변형거동이 나타났으며 이로 인해 음의 포아송비기 발생하였다. 음의 횡변형율은 예열시험편의 냉각과정동안 결정입자의 유발된 잔류응력에 의해 발생하는 것으로 생각된다.

  • PDF

Lateral buckling of reinforced concrete beams without lateral support

  • Aydin, Ruhi;Kirac, Nevzat
    • Structural Engineering and Mechanics
    • /
    • 제6권2호
    • /
    • pp.161-172
    • /
    • 1998
  • Reinforced concrete beams possess variable flexural and torsional stiffnesses due to formation of cracks in the tension area along the beam. In order to check the stability of the beam, it is thus more appropriate to divide the beam into a finite number of segments for which mean stiffnesses and also bending moments are calculated. The stability analysis is further simplified, by using these mean values for each segment. In this paper, an algorithm for calculating the critical lateral buckling slenderness ratio for a definite load level, in a reinforced concrete beam without lateral support at the flanges, is presented. By using this ratio, the lateral buckling safety level of a slender beam may be checked or estimated.

표면거칠기를 가진 유리의 입자충격 손상기구에 관한 실험적 연구 (An Experimental Study on the Damage Mechanism of Particle Impact in a Scratched Glass)

  • 서창민;정성묵;이문환
    • 대한기계학회논문집A
    • /
    • 제20권7호
    • /
    • pp.2196-2204
    • /
    • 1996
  • The damage mechanism by the impact of steel ball on the soda-lime glass having a different surface roughness was investigated. An initiation and a propagation behavior of cracks formed by each impact velocity were quantitatively studied. A 4-point bending test was carried out to evaluate the remaining bending strength of a scratched soda-lime glass which impacted by the steel ball. As the surface roughness was increased, the shape of cracks became more irregular rather than those of the smooth specimens. The phenomenon of turning up in the wing of cone cracks occurred even at the lower velocity than the critical velocity caused the crushing. The threshold velocity of cracks initiation generally became lower than those of smooth specimen. An initiation and a propagation behavior of radial cracks had no relation with the direction of scratch on the surface. The remaning benidng strength of the scratched specimen according to impact velocity had no big difference compared with those of the smooth specimen.

Experimental study on shear damage and lateral stiffness of transfer column in SRC-RC hybrid structure

  • Wu, Kai;Zhai, Jiangpeng;Xue, Jianyang;Xu, Fangyuan;Zhao, Hongtie
    • Computers and Concrete
    • /
    • 제23권5호
    • /
    • pp.335-349
    • /
    • 2019
  • A low-cycle loading experiment of 16 transfer column specimens was conducted to study the influence of parameters, likes the extension length of shape steel, the ratio of shape steel, the axial compression ratio and the volumetric ratio of stirrups, on the shear distribution between steel and concrete, the concrete damage state and the degradation of lateral stiffness. Shear force of shape steel reacted at the core area of concrete section and led to tension effect which accelerated the damage of concrete. At the same time, the damage of concrete diminished its shear capacity and resulted in the shear enlargement of shape steel. The interplay between concrete damage and shear force of shape steel ultimately made for the failures of transfer columns. With the increase of extension length, the lateral stiffness first increases and then decreases, but the stiffness degradation gets faster; With the increase of steel ratio, the lateral stiffness remains the same, but the degradation gets faster; With the increase of the axial compression ratio, the lateral stiffness increases, and the degradation is more significant. Using more stirrups can effectively restrain the development of cracks and increase the lateral stiffness at the yielding point. Also, a formula for calculating the yielding lateral stiffness is obtained by a regression analysis of the test data.